PubMed Health⌕ Search

Biomedical subjects

J C Lancaster

Publications and source records attributed to J C Lancaster.

4 recordsLinked to original sources

Engineering very-high-n polarized Rydberg states using tailored half-cycle-pulse sequences.

We show that strongly polarized very-high-n (n approximately 600) potassium Rydberg atoms can be produced by manipulating lower-n (n approximately 350) polarized atoms using a tailored sequence of ultrashort half-cycle pulses (HCPs). The protocol for this involves first a weak HCP that generates transient phase-space localization whereupon a second large HCP of opposite polarity excites the electron to a broad distribution of highly elongated states. This distribution is then refocused by a short periodic train of HCPs using the properties of (un)stable manifolds near fixed points in phase space.

Journal Article↗

Real-time digital K-edge subtraction fluoroscopy.

We report in vitro and in vivo trials of K-edge fluoroscopy, by which iodine contrast concentration is displayed live, with tissue and bone images suppressed, free of patient-motion artifacts. Iodine and cerium, 125 and 225 mg/cm2 respectively, filter alternate TV fields of cine-pulsed 50 KVP x-rays. Weighted subtraction of successive TV fields isolates the iodine image and simultaneously minimizes artifacts. Digital techniques are used in real time. At our present x-ray tube limit, 500 mA instantaneous current, the patient exposure is 180 mR/sec and quantum mottle limits the image quality. Integrating four successive difference images provides a compromise between mottle and smoothly moving displays. Cardiovascular images of a 17-kg dog, using 1 ml/kg Renografin-60 injected into a foreleg vein, show that a 15-cm chest thickness is our present practical maximum. This method may be useful in diagnosing cardiovascular anomalies in infants without catheterization or suspension of breathing.

Animals↗

Computerized fluoroscopy techniques for intravenous study of cardiac chamber dynamics.

A computerized fluoroscopy system which was recently developed in our laboratories permits image contrast increases of 8-16 relative to conventional image intensifer fluoroscopy and permits study of canine and human ventricular wall motion using peripheral intravenous injections. Two time-dependent image subtraction algorithms are illustrated in connection with observation of artificially infarcted dog hearts. The first algorithm produces a display analogous to direct ventriculography using catheterization. The second displays regions of dyskinetic motion as anomalous image grey shades.

Animals↗