3D coronary reconstruction from routine single-plane coronary angiograms: clinical validation and quantitative analysis of the right coronary artery in 100 patients.

BACKGROUND: Current coronary angiographic techniques display complex three-dimensional (3D) coronary structures in two dimensions (2D). We have developed a 3D reconstruction (3DR) algorithm using standard single-plane angiographic images that allows for 3D display of coronary structures. The purpose of this study was to validate our 3DR algorithm and quantify anatomic characteristics of the right coronary artery (RCA) in vivo. METHODS: Accuracy and reproducibility studies were performed using 3DRs of a coronary phantom and in vivo following 3DRs in 40 patients. The anatomic features of the RCA were then quantified in 100 patients. RESULTS: Comparison of length and bifurcation angles (BA) from the phantom to the 3DRs revealed good accuracy and correlation for both (r = 0.95 and 0.93 respectively), with diameter error of < 7%. In vivo, the average root mean square (RMS) error in the spatial coordinates of the vessel centerlines was 3.12 +/- 0.77 and 3.16 +/- 0.75 mm in 20 left coronary arteries (LCA) and 20 RCAs respectively. Interobserver average RMS error was 3.47 +/- 1.96 mm and intraobserver average RMS error was 3.02 +/- 1.07 and 3.44 +/- 1.57 mm for two different operators (p = NS). The average RCA length was 10.2 +/- 1.7 cm, average radius of curvature (ROC) was 52 +/- 9 degrees, and the average 3D bifurcation angle of the posterior descending artery (PDA) from the RCA was 55 +/- 22 degrees. Foreshortening (FS) of the segments of the RCA in three 'standard' projections ranged from 0-60, 0-75, and 0-82% respectively. CONCLUSIONS: Using our 3DR algorithm patient-specific anatomic characteristics can be accurately displayed and quantified, expanding the information that can be derived from routine coronary angiography.

Algorithms↗

Transesophageal echocardiographic visualization of left ventricular malpositioned pacemaker electrodes: implications for lead extraction procedures.

Two cases of malpositioned LV electrodes are presented. Transesophageal echocardiography (TEE) allowed for a careful inspection of left-sided leads and for tracking their course. One LV and two right-sided leads were safely retrieved with TEE monitoring. One chronic LV lead was left in place as it was heavily fibrosed. TEE was helpful in the inspection and monitoring of the extraction and also in guided traction efforts. This is the first published report of echocardiographic visualization of the lead retrieval procedure.

Adult↗

Hyperbaric oxygen and thrombolysis in myocardial infarction: the 'HOT MI' randomized multicenter study.

In a previous pilot study, we demonstrated that adjunctive treatment with hyperbaric oxygen (HBO) appears to be feasible and safe in patients with acute myocardial infarction (AMI) and may result in an attenuated rise in creatine phosphokinase (CPK), more rapid resolution of pain and ST changes. This randomized multicenter trial was organized to further assess the safety and feasibility of this treatment in human subjects. Patients with an AMI treated with recombinant tissue plasminogen activator (rTPA) or streptokinase (STK), were randomized to treatment with HBO combined with either rTPA or STK, or rTPA or STK alone. An analysis included 112 patients, 66 of whom had inferior AMIs (p = NS). The remainder of the patients had anterior AMIs. The mean CPK at 12 and 24 h was reduced in the HBO patients by approximately 7.5% (p = NS). Time to pain relief was shorter in the HBO group. There were 2 deaths in the control and 1 in those treated with HBO. The left ventricle ejection fraction (LVEF) on discharge was 51.7% in the HBO group as compared to 48.4% in the controls (p = NS). The LVEF of the controls was 43.4 as compared to 47.6 for those treated, approximately 10% better (no significant difference). Treatment with HBO in combination with thrombolysis appears to be feasible and safe for patients with AMI and may result in an attenuated CPK rise, more rapid resolution of pain and improved ejection fractions. More studies are needed to assess the benefits of this treatment.

Adolescent↗

Hyperbaric oxygen and thrombolysis in myocardial infarction: the "HOT MI" pilot study.

Hyperbaric oxygen treatment (HBO) in combination with thrombolysis has been demonstrated to salvage myocardium in acute myocardial infarction in the animal model. Therefore a randomized pilot trial was undertaken to assess the safety and feasibility of this treatment in human beings. Patients with an acute myocardial infarction (AMI) who received recombinant tissue plasminogen activator (rTPA) were randomized to treatment with HBO combined with rTPA or rTPA alone. Sixty-six patients were included for analysis. Forty-three patients had inferior AMIs (difference not significant) and the remainder had anterior AMIs. The mean creatine phosphokinase level at 12 and 24 hours was reduced in the patients given HBO by approximately 35% (p = 0.03). Time to pain relief and ST segment resolution was shorter in the group given HBO. There were two deaths in the control group and none in those treated with HBO. The ejection fraction on discharge was 52.4% in the group given HBO compared with 47.3% in the control group (difference not significant). Adjunctive treatment with HBO appears to be a feasible and safe treatment for AMI and may result in an attenuated rise in creatine phosphokinase levels and more rapid resolution of pain and ST segment changes.

Adolescent↗

Cardiac pacemaker electrodes: improved methods of extraction. Work in progress.

PURPOSE: To develop improved methods of extracting pacemaker electrodes from the femoral vein by using standard equipment and techniques. MATERIALS AND METHODS: Pacemaker electrodes were removed from 61 patients aged 21-91 years (mean, 68 years). In 25 patients (41%), traction was applied to locking stylets to remove electrodes at the subclavian vein entry site. In 30 patients, the electrode tip was freed with traction at the subclavian vein entry site. The electrode was then extracted through a sheath placed in the femoral vein. In six patients (10%), the electrode tip was freed via the femoral vein when traction was applied to grasping devices. The electrode was then removed through a femoral venous sheath. RESULTS: Ninety-nine (95%) of 104 pacemaker electrodes were extracted completely. Two electrodes were trapped in fibrous tissue in the subclavian vein. One right atrial tear occurred. CONCLUSION: Pacemaker electrodes can be removed effectively by using percutaneous techniques.

Aged↗

2 chlorodeoxyadenosine activity and cross resistance patterns in primary cultures of human hematologic neoplasms.

2-Chlorodeoxyadenosine (2-CDA) is an adenosine deaminase resistant analogue of deoxyadenosine which has shown clinical activity in human hematologic neoplasms. The exact mode of action of this drug remains the subject of investigation. We applied the Differential Staining Cytotoxicity (DiSC) assay to 50 human tumour specimens obtained from patients with a variety of hematologic malignancies to characterise the activity spectrum of 2-CDA. We evaluated the disease-specific activity of this agent in vitro and compared its relative cytotoxicity with that of other antineoplastic agents in current clinical use. Comparisons were conducted against nitrogen mustard, doxorubicin, vincristine and cytosine arabinoside. Our results indicate that 2-CDA has activity in myeloid and many lymphoid neoplasms but that multiple myeloma specimens reveal significant resistance. Cross resistance studies reveal a correlation between 2-CDA and the alkylator nitrogen mustard but no correlation between 2-CDA and doxorubicin, vincristine nor cytosine arabinoside. The results suggest 2-CDA activity in many human hematologic neoplasms with the clear exception of multiple myeloma and further suggest a relationship between this agent and alkylators of the mustard class. The DiSC assay may provide useful insights in the pre-clinical evaluation of new antineoplastic drugs and may help to elucidate drug activities and mechanisms of action.

Cladribine↗

Dacron-woven pacemaker pouch. Influence on long-term pacemaker mobility.

Pacemaker migration can interfere with correct pacing system function and patient comfort. A Dacron pouch has been developed which may prevent these problems. To assess the efficacy of the pouch, we measured various factors of pacemaker mobility in 100 patients after long-term follow-up. The patients were divided into three groups on the basis of their dictated operative reports: group 1, no pouch or anchoring stitch; group 2, pouch only; group 3, anchoring stitch to pacemaker header or pouch. The average age of the study population was 74.3 +/- 11 years. Total follow-up time was 42 +/- 28 months (group I, 53 +/- 32 months; group 2, 36 +/- 23 months; group 3, 34 +/- 25 months). There were no significant differences when pacemakers were measured for movement in the inferosuperior and lateromedial directions, nor was there any difference in the distance between the incision scar and the pacemaker header in any group. There was a significant difference between group 1 and groups 2 and 3 when the degree of tilt of the pacemaker off the chest wall was compared. This was 46 degrees +/- 34 degrees for group 1 and 27 degrees +/- 26 degrees and 26 degrees +/- 27 degrees for groups 2 and 3, respectively (p less than 0.02 for both). These data suggest that the Dacron pouch does not restrict pacemaker mobility parallel to the chest wall during long-term follow-up but does reduce the angle to which the pacemaker can be tilted relative to the chest wall.

Aged↗

Enhancement of anthracycline and alkylator cytotoxicity by ethacrynic acid in primary cultures of human tissues.

Ethacrynic acid [2,3-dichloro-4-(2-methylene-1-oxobutyl)phenoxyl] acetic acid, is a water-soluble diuretic agent that has been shown to potentiate the in vitro cytotoxicity of chemotherapeutic agents in established cell lines. We used the differential staining cytotoxicity (DiSC) assay to determine whether ethacrynic acid at 1 and 3.3 microM would potentiate the cytotoxicity of nitrogen mustard and/or doxorubicin in primary cultures of hematologic neoplasms from heavily pretreated patients and in normal peripheral blood lymphocytes. At 3.3 microM, ethacrynic acid was toxic to 8 of 24 (33%) tumor specimens studied. In subsequent studies, ethacrynic acid at 1 microM was toxic to only 2 of 54 (4%) tumor specimens. Significant enhancement for doxorubicin or nitrogen mustard was confined to lymphatic malignancies and to normal peripheral blood lymphocytes. Interspecimen variability was observed, with no enhancement in most individual specimens, 2-fold enhancement in some specimens, and 4-fold enhancement in occasional specimens. Clinical trials will be required to determine whether the observed in vitro activity for ethacrynic acid is associated with clinical benefit in unselected or assay-selected patients.

Cell Survival↗

Atrial automatic tachycardia-reversion pacemakers: their economic viability and impact on quality-of-life.

UNLABELLED: Refractory supraventricular tachyarrhythmias may be both difficult and costly to control medically and can interfere with the patient's lifestyle. Newer treatment modalities are available for their management, and these require comprehensive assessment. We therefore compared costs and selective indices of patient benefit in a group of 17 patients in whom an atrial antitachycardia (Intermedics Intertach 262-12) pacemaker was placed for refractory supraventricular tachyarrhythmias. Prior medical therapy was compared to subsequent automatic antitachycardia pacemaker treatment. The total medical costs (admissions, emergency room visits, office visits, and medication costs) and the number of hospitalizations and medications were compared prior to implantation (F/U 69.3 +/- 61 months) and after implantation (F/U 15.3 +/- 7.8 months). A detailed quality-of-life questionnaire was also obtained 36.6 +/- 11 months after implantation. RESULTS: There were significant per patient differences in total cost before and after implantation: monthly costs were $505 +/- $833 before pacemaker implantation and $105 +/- $117 monthly afterward (P less than 0.005). Pacemaker implantation hospitalization costs were $19,063 +/- $8,362. Monthly medication costs averaged $46 before versus $15 after implantation (P less than 0.01). The number of medication types also differed with an average 5.5 medication types per patient before versus 1.2 after implantation (P less than 0.001). There were 8.6 yearly hospital admissions in the whole group before implantation, versus 4.7 admissions in the group per year thereafter. Patients demonstrated significant improvement in 80% of the quality-of-life parameters studied. CONCLUSION: Adjunctive atrial automatic tachycardia-reversion pacemaker therapy may be cost-competitive over time when compared to medical therapy alone in patients with refractory supraventricular tachyarrhythmias and appears to improve overall quality-of-life.

Costs and Cost Analysis↗

The influence of endocardial electrode fixation status on acute and chronic atrial stimulation threshold and atrial endocardial electrogram amplitude.

UNLABELLED: The endocardial atrial electrogram or "P wave amplitude" (PWA) and pacemaker atrial stimulation thresholds are important parameters determining correct pacing system function. Pacemaker lead fixation mechanism and lead age may negatively influence these parameters. Therefore, we compared acute and chronic PWA and atrial stimulation thresholds in 33 patients with permanent transvenous atrial screw-in leads, follow-up 647 days +/- 297 days; and in 31 patients with nonscrew leads, follow-up 855 days +/- 512 days (P = ns). RESULTS: The PWA differed between the two lead types acutely (1.97 mV +/- 0.8 mV for screw-in versus 2.48 mV +/- 1.1 mV for nonscrew-in leads; P less than 0.05), but not chronically (2.21 mV +/- 0.8 mV vs 2.2 mV +/- 1.2 mV; P = ns). Acute and chronic atrial pacing thresholds did not differ between groups. We also analyzed an early interim PWA in a subgroup of patients (mean 31 days after implantation). The nonscrew fixation group interim PWA was 1.76 mV +/- 0.9 mV versus 2.7 mV +/- 1.2 mV at implant (P less than 0.001). The screw-in lead interim PWA was 2.04 mV +/- 0.9 mV versus 1.97 mV +/- 0.7 mV at implant (P = ns). CONCLUSIONS: (1) A significantly higher endocardial PWA occurs at the time of lead implantation in nonscrew versus screw-in lead groups, but the chronic PWA does not differ between the two groups. (2) A transient but marked early (mean approximately 31 days) attenuation of the PWA occurs only with nonscrew-in leads. (3) Atrial threshold stimulation energies do not differ between the two lead groups acutely or during follow-up.

Aged↗

Physical determinants of the endocardial P wave.

UNLABELLED: Reliable atrial sensing of intrinsic P wave activity is important to ensure optimal atrial or dual chamber pacemaker function. Various physical factors (e.g., posture, respiration, exercise) may influence P wave characteristics and impair adequate sensing. To investigate this phenomenon, we measured the average of three P wave amplitudes (PWA) and calculated slew rates from telemetered printouts acquired from Pacesetter pacemakers in 32 patients. These measurements were performed in various body positions, with upright exercise and in varying stages of respiration. RESULTS: the mean supine PWA increased on full inspiration (3.56 +/- 1.3 mV versus 3.25 +/- 1.2 mV during quiet respiration, P less than 0.001), and also increased significantly with full expiration. The mean PWA increased on assuming the erect position (3.25 +/- 1.2 mV increasing to 3.49 +/- 1.3 mV, P less than 0.001); in the upright position, the mean erect PWA during quiet respiration was not significantly influenced by the stage of respiration. The mean upright exercise PWA did not differ significantly from the preexercise erect PWA (3.50 +/- 1.2 with exercise, and 3.47 +/- 1.5 before exercise; P = NS). Calculated slew rates were not different lying versus standing. CONCLUSIONS: the mean supine PWA increases significantly at the extremes of respiration and on assuming the erect body position; upright exercise results in no appreciable change in the erect PWA. Atrial sensitivity adjustments based on standard supine testing should be adequate for all body positions.

Adolescent↗

True incidence of pacemaker syndrome.

Although the purported incidence of pacemaker syndrome according to the literature is only 5%-15%, this is based on a series of patients with VVI pacing. Increasing numbers of studies are being reported in which patients prefer the dual chamber mode despite little benefit being demonstrated on objective testing, suggesting that pacemaker syndrome may be more common than is generally reported. This study was designed to evaluate the reported symptoms in a series of patients programmed to both the VVI and one or more dual chamber modes. Forty unselected patients with dual chamber pacemakers were entered into a blind, randomized trial comparing the symptoms associated with VVI pacing to those associated with dual chamber pacing. Patients were randomized to either VVI or dual chamber pacing. At the end of 1 week, questionnaires rating 16 different symptoms were completed. Blood pressure, LV function, presence of ventriculoatrial conduction, and ability to override the pacemaker were evaluated. The pacemaker was then programmed to the other mode. Overall, 12 of 16 symptoms were significantly worse in the VVI as compared to dual chamber mode. The most highly significant (P less than 0.005) were shortness of breath, dizziness, fatigue, pulsations in the neck or abdomen, cough, and apprehension. Pacemaker syndrome was clinically recognized in 83% of patients paced in the VVI mode with 65% of patients experiencing moderate to severe symptoms. There were no readily identified clinical, hemodynamic, or electrophysiological parameters that predicted which patients would develop pacemaker syndrome. Thus, when patients have an opportunity to experience both pacing modes in close proximity to one another, there is a high incidence of pacemaker syndrome in the VVI mode.

Aged↗

Variation in P wave amplitude immediately after pacemaker implantation: possible mechanism and implications for early programming.

The P wave amplitude (PWA) plays an important role in determining atrial sensing capabilities. To assess early PWA change, we compared the unipolar PWA in 43 patients at the time of atrial lead placement, measured by a pacing systems analyzer, to the unipolar PWA recorded at the end of pacemaker surgery, from telemetered atrial endocardial electrograms. Individual PWA varied from a decrease of 5.2 mV to an increase of 2 mV (-63% to 267%). In 33 patients with active fixation leads, the implant PWA was 1.96 +/- 0.99 mV versus 2.4 +/- 1.4 mV after surgery. In 11 patients with passive fixation leads, the implant PWA was 2.8 +/- 1.9 mV versus 1.9 +/- 0.8 mV after surgery. The PWA change, measured as the difference between the postsurgical and implant PWA was 0.43 +/- 0.8 mV in active versus -0.86 +/- 1.6 mV in the passive fixation lead groups (P less than 0.05). Considerable change in individual P wave amplitude can therefore occur very early after pacemaker implantation. The direction differs significantly between active (predominantly positive) and passive fixation groups (predominantly negative). These data suggest that an adequate margin of safety is important when initially programming atrial sensitivity, particularly when using passive fixation leads.

Aged↗

Impaired activity rate responsiveness of an atrial activity-triggered pacemaker: the role of differential atrial sensing in its prevention.

The physiological benefit of rate responsive, single-chamber cardiac pacing is well documented. We studied the activity response of nine atrially placed Activitrax II pacemakers. Seven patients were noted to have an inadequate activity-rate response with maximal pacing rates of 85 to 101 beats/min. Marker Channel analysis revealed that the upper rate timeout was reset by far-field R wave sensing, even when sensing occurred in the atrial refractory period. These 9 pacemakers were tested by atrial sensitivity adjustment for ability to exclude far-field R wave sensing, while preserving P wave sensing. Unipolar implantation data were then examined for predictors of this differential far-R and P-wave sensing. Differential atrial sensing occurred in 4/9 pacemakers (2/2 bipolar in the right atrial appendage; 0/1 bipolar in the coronary sinus; and 4/9 unipolar). An empirically developed index utilizing unipolar implant parameters discriminated outcomes for 8/9 unipolar pacemakers. We conclude that: (1) the rate responsiveness of the atrial Activitrax II pacemaker is limited by far-field R wave sensing even when this occurs during atrial channel refractoriness; (2) reprogramming atrial sensitivity to differentially sensed P and far-field R waves may restore appropriate rate responsiveness; and (3) although a unipolar implant discriminant index may correctly identify adequacy of future rate responsiveness, the atrial application of the Activitrax II pacemaker is cautioned until further validation is forthcoming, particularly when used in unipolar and coronary sinus applications.

Adult↗

Utility of the atrial endocardial electrogram concurrent with dual-chamber pacing in the determination of a pacemaker-mediated arrhythmia.

A 73-year-old male required a permanent pacemaker for complete heart block. After placement of the dual-chamber pacemaker, the patient developed random, repetitive ventricularly paced coupling at the upper rate limit. The diagnosis made from the surface electrocardiography was one of ventricular tracking of occult (T wave obscured) atrial ectopic activity. Examination of the telemetered atrial electrogram (EGM) revealed a diagnosis of intermittent far-field atrial sensing of the terminal ventricular depolarization. The value of obtaining an atrial electrogram during dual-chamber pacing is discussed.

Aged↗

Transient central diabetes insipidus after aortocoronary bypass operations.

Three cases of transient central diabetes insipidus after cardiopulmonary bypass are presented. All 3 patients responded promptly to administration of vasopressin, and were completely recovered from polyuria 10 days after cardiac surgery. It is postulated that transient diabetes insipidus after cardiac operation occurred in some patients who had preexisting selective osmoreceptor dysfunction when cardiac standstill during extracorporeal circulation alters the left atrial nonosmotic receptor function, resulting in suppression of antidiuretic hormone release.

Arginine Vasopressin↗