PubMed Health⌕ Search

Biomedical subjects

J C Peeters

Publications and source records attributed to J C Peeters.

3 recordsLinked to original sources

[The five-word test in memory deficiency].

The 5-Word test is a bedside memory test with free and cued selective recollection. Here, we evaluated its reliability Belgian French speakers. Five groups were studied : normal subjects, depressive patients, patients with AD, patients with vascular dementia and 47 patients for a validation of a logistic model. The results of the 5-Word test with the MMSE, both values were included as variables in a logistic regression model. The probability of diagnosis of AD and dementia can be calculated and used prospectively for assessment of new cases in a validation study. The importance of the study of free and cued response during immediate and delayed recall was assessed by variance analysis in 4 groups. A third order interaction (p < 0.001) was observed between the normal and AD groups, the normal and vascular dementia (VD) groups and between AD and VD groups. With this initial model, 98% of the 62 normal subjects and the 57 patients with AD were correctly classified (p < 0.001). For AD diagnosis at the onset, the sensitivity of the MMSE is increased when it is associated with the 5-Word. This low-tech bedside method associating the 5-Word test and MMSE has a good specificity for the diagnosis of AD. It is very useful for screening a population of patients at the onset of cognitive and memory deficiency and for selecting the patients requiring an examination at a memory clinic.

Aged↗

Optical plankton analyser: a flow cytometer for plankton analysis, I: Design considerations.

The design criteria for a flow cytometer (FCM) for the analysis of field samples of phytoplankton are described. The criteria are based on the occurrence of a wide variety of particle sizes in field samples, normally at low concentrations. The instrument should be able to analyse cells and colonies from 0.5 to 500 microns diameter and of over 2,000 microns length. A minimum flow rate of 4 microliters.s-1 was calculated from natural plankton concentrations. Commercially available FCMs are not suited to measure this range of sizes at this rate. Further limitations of standard FCMs are uneven illumination or incomplete processing of long signals. In addition, long filamentous colonies can break into small fragments caused by too high acceleration in the standard flow cuvette. Recognition of these limitations is of importance for the flow cytometry of phytoplankton. The new design was developed to avoid these limitations. A dynamic range 5 to 6 decades could be accomplished by a combination of logarithmic amplifiers, a slit-shaped focal spot, and a pulse integration system that can process long pulses. Multilaser capability to identify different phytoplankton species, a low fluid shear cuvette, and a trigger gate-extension for inhomogeneously fluorescent algal filaments were included in the design.

Electronics↗