Talking about treatment.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J C Peirce.
Explore the source record for details and available documents.
BACKGROUND: Prostate-specific antigen (PSA) levels between 4.0 to 10.0 ng/ml have poor specificity in prostate cancer screening, leading to unnecessary biopsies. OBJECTIVE: To determine whether the free-to-total PSA ratio (F/T PSA) improved the diagnostic accuracy of these nonspecific PSA levels. MEASUREMENTS AND MAIN RESULTS: MEDLINE searchedwas from 1986 to 1997. Additional studies were identified from article bibliographies and by searching urology journals. Two investigators independently identified English-language studies providing F/T PSA ratio test-operating characteristics data on > or = 10 cancer patients with PSA values between 2.0 and 10.0 ng/ml. Twenty-one of 90 retrieved studies met selection criteria. Two investigators independently extracted data on methodology and diagnostic performance. Investigator-selected cut points for the optimal F/T PSA ratio had a median likelihood ratio of 1.76 (interquartile range, 1.40 to 2.11) for a positive test and 0.27 (0.20 to 0.40) for a negative test. Assuming a 25% pretest probability of cancer, the posttest probabilities were 37% following a positive test and 8% following a negative test. The summary receiver operating characteristic curve showed that maintaining test sensitivity above 90% was associated with false positive rates of 60% to 90%. Methodologic problems limited the validity and generalizability of the literature. CONCLUSIONS: A negative test reduced the posttest probability of cancer to approximately 10%. However, patients may find that this probability is not low enough to avoid undergoing prostate biopsy. The optimal F/T PSA ratio cut point and precise estimates for test specificity still need to be determined.
Rapidly changing times in health care challenge both physicians and health care administrators to manage the paradox of providing orderly, high quality, and efficient care while bringing forth innovations to address present unmet problems and surprises that emerge. Health care has grown throughout the past several centuries through differentiation and integration, becoming a highly complex biological system with the hospital as the central attractive force--or "strange attractor"--during this century. The theoretical model of complex adaptive systems promises more effective strategic direction in addressing these chaotic times where the new strange attractor moves beyond the hospital.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
CONTEXT: Adverse drug events (ADEs) are the most common type of iatrogenic injury occurring in hospitalized patients. Errors leading to ADEs are often due to restricted availability of information at the time of physician order writing. OBJECTIVES: To develop, implement, and evaluate a computer alert system designed to correct errors that might lead to ADEs and to detect ADEs before maximum injury occurs. DESIGN: Prospective case series. SETTING: A 650-bed community teaching hospital in Phoenix, Ariz. PATIENTS: Consecutive sample of 9306 nonobstetrical adult patients admitted during the last 6 months of 1997. INTERVENTIONS: Thirty-seven drug-specific ADEs were targeted. Our hospital information system was programmed to generate alerts in clinical situations with increased risk for ADE-related injury. A clinical system was developed to ensure physician notification of alerts. MAIN OUTCOME MEASURES: A true-positive alert was defined as one in which the physician wrote orders consistent with the alert recommendation after alert notification. RESULTS: During the 6-month study period, the alert system fired 1116 times and 596 were true-positive alerts (positive predictive value of 53%). The alerts identified opportunities to prevent patient injury secondary to ADEs at a rate of 64 per 1000 admissions. A total of 265 (44%) of the 596 true-positive alerts were unrecognized by the physician prior to alert notification. CONCLUSIONS: Clinicians can use hospital information systems to detect opportunities to prevent patient injury secondary to a broad range of ADEs.
Explore the source record for details and available documents.
Four fine-needle aspiration biopsy needles with different tip configurations were used in 133 patients with abdominal lesions. The 20-gauge needles were used in random sequence by several physicians. The specimen from each of the 522 needle passes was evaluated by two cytopathologists for adequacy to render a diagnosis and for the presence of cell block material. The Franseen needle produced a 16% and 9% better yield for diagnostic material than did the cut biopsy and spinal needles (P less than .05), respectively. The Westcott needle was better than the cut biopsy needle by 13%, and the spinal needle produced an 11% better yield than did the cut biopsy needle. Differences did not exist in liver biopsies but were present in pancreatic biopsies. The spinal needle was the least successful in yielding cell block material. Use of the cut biopsy needle resulted in the largest proportion of inadequate specimens, except its yield in cell blocks in the liver was 25% higher than that of the Westcott needle. The authors conclude that not all unusual designs for 20-gauge needle tips render results superior to those of the simple spinal needle.
The discussion and general conclusions of a working group convened during the Regenstrief Conference are presented. The group was formed to consider issues involved in the dissemination of research findings relative to decision modeling in the management of cardiovascular disease.
Two hundred six patients with suspected appendicitis were examined with sonography over a 6-month period in three community teaching hospitals. Of 41 patients in whom the surgeons judged the clinical findings severe enough to warrant immediate surgery (group A), 34 (83%) had appendicitis, and sonography had a sensitivity of 0.76, a specificity of 0.71, and an accuracy of 0.76. Of 165 patients in whom the surgeons judged the clinical findings severe enough to warrant hospitalization for observation but not immediate surgery (group B), 51 (31%) had appendicitis at subsequent surgery. Sonography had a sensitivity of 0.96, a specificity of 0.94, and an accuracy of 0.95. Of 49 surgeons surveyed, the mean testing threshold (i.e., the probability of appendicitis below which they would send the patient home without further tests or observation) was 0.11, and the mean treatment threshold (i.e., the probability of appendicitis above which they would operate immediately) was 0.82. The posttest probability of appendicitis with findings indicating appendicitis present on sonography was 0.93 in group A and 0.88 in group B, and with findings absent on sonography it was 0.62 in group A and 0.02 in group B. We conclude that in group A patients, the use of sonography remains controversial in the diagnosis of appendicitis, but in group B patients it is both valid and useful.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
With the use of more stringent diagnostic criteria, it has recently been shown that some large pedigrees of Alport's and non-Alport's hereditary nephritis fit sex-linked dominant inheritance (O'Neill et al. 1978). We have used similar diagnostic criteria and have studied a number of Michigan pedigrees in order to see if this hypothesis would be confirmed. We found one small pedigree which definitely shows male-to-male transmission, while one large pedigree is tentatively compatible with sex-linked dominant inheritance. Many of the other pedigrees suggested male-to-male transmission. This Michigan experience is compared to other published reports and found to be consistent, although a trend of fewer reports of male-to-male transmission is seen. We conclude that genetic heterogeneity of Alport's hereditary nephritis is likely.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.