PubMed Health⌕ Search

Biomedical subjects

J C Principe

Publications and source records attributed to J C Principe.

17 recordsLinked to original sources

A comparison of optimal MIMO linear and nonlinear models for brain-machine interfaces.

The field of brain-machine interfaces requires the estimation of a mapping from spike trains collected in motor cortex areas to the hand kinematics of the behaving animal. This paper presents a systematic investigation of several linear (Wiener filter, LMS adaptive filters, gamma filter, subspace Wiener filters) and nonlinear models (time-delay neural network and local linear switching models) applied to datasets from two experiments in monkeys performing motor tasks (reaching for food and target hitting). Ensembles of 100-200 cortical neurons were simultaneously recorded in these experiments, and even larger neuronal samples are anticipated in the future. Due to the large size of the models (thousands of parameters), the major issue studied was the generalization performance. Every parameter of the models (not only the weights) was selected optimally using signal processing and machine learning techniques. The models were also compared statistically with respect to the Wiener filter as the baseline. Each of the optimization procedures produced improvements over that baseline for either one of the two datasets or both.

Action Potentials↗

Extraction of principal components from biosignals by neural net.

This contribution gives the information on a useful application of principal component analysis (PCA) in the field of electroencephalogram (EEG) and laser-Doppler signal processing. The principal components are estimated by a neural network (NN) approach.

Algorithms↗

Multiresolution segmentation of respiratory electromyographic signals.

Analysis of respiratory electromyographic (EMG) signals in the study of respiratory control requires the detection of burst activity from background (signal segmentation), and focuses upon the determination of onset and cessation points of the burst activity (boundary estimation). This paper describes a new automated multiresolution technique for signal segmentation and boundary estimation. During signal segmentation, a new transitional segment is defined which contains the boundary between background and burst activity. Boundary estimation is then performed within this transitional segment. Boundary candidates are selected and a probability is attributed to each candidate, using an artificial neural network. The final boundary for a given transitional segment is the boundary estimate with the maximum a posteriori probability. This new method has proved accurate when compared to boundaries chosen by two investigators.

Action Potentials↗

STL: a spatio-temporal characterization of focal interictal events.

An innovative method for on-line processing of array ECoG data, the Spatio-Temporal Laplacian, intended for intraoperative epileptic focus localization is presented. This method simultaneously involves the spatial and temporal characteristics of the potential field manifestations peculiar to focal interictal events. A 3-Dimensional (x, y and t) sample space is used to explain and apply the Spatio-Temporal Laplacian (STL) transformation. In particular, a focal interictal event is detected through the coincident spatial and temporal sharpness that it introduces in this sample space. Preliminary results from two subjects are presented and compared with standard bioplar derivation signals, traditionally used in the focus localization task.

Adult↗

3-D computer animation of electrophysiological responses.

Traditional methods for displaying electrophysiological data, that use time as the axis on a plot, are inadequate for displaying data from simultaneous multi-channel recordings. New methods proposed here plot the instantaneous value of the data on a third axis over a 2-dimensional spatial map of the tissue. The resulting 3-D computer-generated surfaces are animated over time to reveal simultaneous coherent waves of activity over the entire slice. This method was implemented for displaying multi-channel evoked potential data from rat hippocampal and human cortical slices. In rat hippocampal slice, stimulation of the Schaffer collateral-commissural pathway in stratum radiatum (SR) near CA2 elicited evoked extracellular responses along the length of CA1 from the alveus to stratum lacunosum moleculare (SLM). 3-D plotting and subsequent animation of these responses translated differential latencies of activation elicited across the slice into coherent moving patterns. These evoked waves of extracellular activity appeared to propagate along hippocampal laminae and were not readily visible in the individual plots. Human temporal cortical slices were stimulated in the white matter and evoked responses recorded in an array format. Upon plotting and animation, activity was seen to propagate vertically to the pial surface and thereafter move radially away from the stimulation site. Animation of 3-D plots of electrophysiological activity can provide instantaneous visual information on correlated changes in amplitude and latency over an entire brain slice. This means of displaying data can reduce a large number of complex wave forms to simple events and allow the simultaneous visualization of general patterns of activity in a large group of neurons.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Chaotic activity during iron-induced "epileptiform" discharge in rat hippocampal slices.

Low-dimensional chaotic dynamics have been suggested in the rat hippocampal slice during iron-induced epileptiform activity. The dimensionality of this chaotic activity has been found to be similar in slices bathed in the same ionic extracellular medium. Some slices also displayed a drop in dimensionality prior to the onset of seizure-like activity. We suggest that techniques of nonlinear dynamical analysis are a useful reverse-engineering tool for studying the in vitro brain slice. We further conclude that neuronal circuits capable of displaying chaotic activity could exist at the level of the in vitro brain slice.

Animals↗

TDAT--time domain analysis tool for EEG analysis.

An interactive design and analysis tool for displaying and quantifying multiple channels of data is presented. The system allows one to easily visualize multiple data channels and simultaneously observe the effects of filters on the data and to evaluate signal detection algorithms. The software is designed for a workstation environment; it will find application in a variety of applications where one needs to simultaneously visualize multiple data channels. TDAT is being used for the design and evaluation of filters and detection algorithms for electroencephalogram (EEG) waveforms, and it is serving as a prototype of a paperless system to be used by electroencephalographers. This paper describes the general software structure of the system and illustrates many of the system features with examples.

Algorithms↗

Sleep staging automaton based on the theory of evidence.

This paper addresses sleep staging as a medical decision problem. It develops a model for automated sleep staging by combining signal information, human heuristic knowledge in the form of rules, and a mathematical framework. The EEG/EOG/EMG events relevant for sleep staging are detected in real time by an existing front-end system and are summarized per minute. These token data are translated, normalized, and constitute the input alphabet to a finite state machine (automaton). The processed token events are used as partial belief in a set of anthropomimetic rules, which encode human knowledge about the occurrence of a particular sleep stage. The Dempster-Shafer theory of evidence weighs the partial beliefs and attributes the minutes sleep stage to the machine state transition that displays the highest final belief. Results are briefly presented.

Algorithms↗

A data compression algorithm for the electroencephalogram.

This paper describes a data compression algorithm for the EEG using a local error measure. The algorithm discards input signal samples provided they can be reconstructed from the stored samples with an error smaller than a given threshold, and according to simple reconstruction functions (the hold, the ramp, and the cosine). An equivalent (in terms of storage) sampling rate of 44 Hz is achieved without noticeable degradation of the signal quality for visual analysis. The method can be easily implemented for real time multichannel data compression/reconstruction.

Algorithms↗

A study on the best order for autoregressive EEG modelling.

The autoregressive (AR) model is a widely used tool in electroencephalogram (EEG) analysis. The dependence of the AR model on both the segment length and several characteristic EEG patterns is addressed. The best AR model order is computed with three different criteria. The results show that the Rissanen criteria provides the more consistent order estimate for the EEG patterns considered. This study shows that for our data set, a 5th order AR model represents adequately 1- or 2-s EEG segments with the exception of featureless background, where higher order models are necessary.

Electroencephalography↗

Automatic recognition of spike and wave bursts.

This paper reviews previous methods and describes a new method for the detection of spike and wave bursts in a single EEG channel. The complete detector is readily implemented in a 16-bit microprocessor. The burst detection relies on the detection of both spikes and waves and also imposes a requirement on the repetition rate of the slow waves. The system agreement with electroencephalographers was over 90% for spike and wave bursts longer than 3 sec in duration, with a false detection rate of one error in 5.8 h for bursts of the same length. The system also computes the mean value and variance of the amplitude and duration of the spikes and slow waves as well as the period of the spike and wave complexes. The EEGs of 6 patients suffering from petit mal epilepsy were analyzed. The variance of the amplitude measures was found to be much greater than that of the period measurements. For all patients the repetition period of the waves decreased for longer bursts, as did the variability of the repetition period. The difficult problem of false detections due to artifacts is discussed in detail.

Action Potentials↗

Microcomputer-based system for the detection and quantification of petit mal epilepsy.

A petit mal seizure detector totally implemented in a 16 bit microcomputer and capable of analyzing on-line at least one channel of EEG data is described. The system uses the repetition period of the wave complexes as the primary parameter for the detection and performs well in clinically significant seizures. Besides characterizing the paroxysms in duration and time of occurrence, the system also evaluates on-line the mean values and variances of the detection parameters, yielding more quantitative information about the seizure data than previously described systems.

Diagnosis, Computer-Assisted↗

Sleep spindle characteristics as a function of age.

The characteristics of sleep spindles as a function of age were studied with an automated analysis system. Five age groups (group 0, 3-5 years; I, 13 years; II, 25-34 years; III, 42-53 years; and IV, 67-79 years) were analyzed. Significant differences in spindle frequency were found between groups 0-I and II-III-IV. The frequency increased with increasing age. No age differences were found in spindle duration. Spindle amplitude reached a peak in the group I subjects, then decreased with increasing age.

Adolescent↗