PubMed Health⌕ Search

Biomedical subjects

J C S Chan

Publications and source records attributed to J C S Chan.

5 recordsLinked to original sources

Subchondral insufficiency fracture of the femoral head.

Subchondral insufficiency fracture of the femoral head is a recently recognised entity. There are a few cases reported in Japanese and Caucasian patients but none in the Hong Kong population. The condition typically occurs in elderly females with osteoporosis. Acute hip pain is the usual presentation. The patient may have concomitant insufficiency fractures elsewhere. Magnetic resonance imaging is usually required to make the diagnosis. The prognosis of the condition is unknown. Reported complications include rapid collapse of the femoral head and coxopathy. Joint replacement should be considered if conservative management fails.

Aged↗

Bone scintigraphy in common tumors with osteolytic components.

Osteolytic lesions are frequently encountered in clinical practice. Radionuclide bone scans with technetium-99m-labeled diphosphonates are often performed in the evaluation of both solitary and multiple osteolytic lesions. In this pictorial review, we critically evaluate the current role of bone scan in common osteolytic tumors including aneurysmal bone cyst, simple bone cyst, fibrous dysplasia, nonossifying fibroma, giant cell tumor, eosinophilic granuloma, enchondroma, chondrosarcoma, osteosarcoma, Ewing sarcoma, myeloma, and metastases. The merits and limitations of bone scanning are emphasized.

Aged↗

Prone table stereotactic breast biopsy.

The prone table machine is a mammographic X-ray system specially designed for use in the stereotactic localisation of breast abnormality. In this study, its clinical usefulness was investigated in terms of duration, success rate, complications, and patients' acceptance of the procedure. During a 5-month period, 79 patients attended the Kwong Wah Hospital for stereotactic-guided biopsy on the prone table. Eighty-one lesions were assessed-seven by fine needle aspirations, 67 by large-core needle biopsies, and seven by vacuum-assisted biopsies. Most of the biopsies were done because of clustered microcalcifications (77.8%) and the majority were of mammographically indeterminate nature (58.0%). The mean duration of the procedure was 49 minutes. A high degree of acceptance was experienced by patients. Only one patient had persistent haemorrhage after the biopsy. In conclusion, the prone table machine was considered to be useful and efficient, and had a high degree of acceptance among patients.

Adult↗