PubMed Health⌕ Search

Biomedical subjects

J C Tutor

Publications and source records attributed to J C Tutor.

At least 19 recordsLinked to original sources

Biochemical characterization of the GM2 gangliosidosis B1 variant.

The deficiency of the A isoenzyme of beta-hexosaminidase (Hex) produced by different mutations of the gene that codes for the alpha subunit (Tay-Sachs disease) has two variants with enzymological differences: the B variant consists of the absence of Hex A isoenzyme and the B1 variant produces an inactive Hex A isoenzyme for the hydrolysis of the GM2 ganglioside and synthetic substrates with negative charge. In contrast to the early childhood form of the B variant, the B1 variant appears at a later clinical stage (3 to 7 years of age) with neurodegenerative symptoms leading to the death of the patient in the second decade of life. The most frequent mutation responsible for the GM2 gangliosidosis B1 variant is R178H, which has a widespread geographic and ethnic distribution. The highest incidence has been described in Portugal, which has been suggested as the point of origin of this mutation. Biochemical characterization of this lysosomal disease is carried out using negatively charged synthetic alpha subunit-specific sulfated substrates, since Hex A isoenzyme heat-inactivation assays are not applicable. However, the determination of the apparent activation energy of Hex using the neutral substrate 3,3'-dichlorophenolsulfonphthaleinyl N-acetyl-beta-D-glucosaminide, may offer a valid alternative. The presence of an alpha subunit in the alphabeta heterodimer Hex A means that its activation energy (41.8 kJ/mol) is significantly lower than that of the betabeta homodimer Hex B (75.1 kJ/mol); however, as mutation inactivates the alpha subunit, the Hex A of the B1 variant presents an activation energy that is similar to that of the Hex B isoenzyme.

Child↗

Assessment of copper status in pregnancy by means of determining the specific oxidase activity of ceruloplasmin.

BACKGROUND: Conditions not directly related to copper nutriture, such as pregnancy, infections and inflammation, which increase serum copper concentration even during copper deprivation, may be expected to conceal changes in copper status. It has been suggested that the specific enzymatic activity of ceruloplasmin (activity per unit mass of enzyme protein) may be a sensitive indicator of copper status and is not affected by factors such as hormones or sex. In this study, we investigated the behaviour of specific oxidase activity of ceruloplasmin and the copper/ceruloplasmin ratio in pregnant women. METHODS: Copper, immunoreactive ceruloplasmin and its oxidase activity were determined in serum from 52 women in the last trimester of normal pregnancy, and in 50 control women of similar age living in the same area and who were not taking oral contraceptives. The results are expressed as mean+/-S.E.M. RESULTS: In the group of pregnant women, significantly higher serum levels of copper, ceruloplasmin and its oxidase activity were found than in the control group (p < 0.001). In both groups, a high correlation was found between these biochemical variables (r > or =0.905, p < 0.001). However, in the group of pregnant women the specific oxidase activity for ceruloplasmin (364.4+/-3.3 vs. 407.5+/-3.8 U/g) and the copper/ceruloplasmin ratio (2.82+/-0.03 vs. 3.19+/-0.04 microg/mg) were significantly lower than in the control group (p < 0.001). CONCLUSIONS: Although pregnancy accelerates the rate of ceruloplasmin protein synthesis and release with an increase of serum copper, the decrease in specific oxidase activity of circulating ceruloplasmin would be an indicator of the degree of depletion of the mother's copper deposits in order to deal with the foetus' needs.

Adolescent↗

Serum cystatin C-immunoglobulin high-molecular-weight complexes in kidney and liver transplant patients.

BACKGROUND: It has been suggested recently that the glomerular filtration rate (GFR) in renal transplant patients is underestimated by serum cystatin C due to an impaired filtration of complexed cystatin C with immunoglobulins. Consequently, serum cystatin C may not be a reliable marker of GFR in these patients. Our study was designed to determine whether this supposition is correct. METHODS: In 87 serum samples from patients with various kidney diseases, 182 samples from renal transplant patients, and 72 samples from liver transplant patients, the concentrations of cystatin C and creatinine were determined, as well as the residual concentration of cystatin C after precipitation of macromolecules with polyethylene glycol (PEG; 6000 molecular weight). RESULTS: The residual concentration of serum cystatin C after precipitation with PEG in all cases was much higher (70 to 100%) than that expected in the case of the existence of cystatin C-immunoglobulin complexes. In the kidney and liver transplant patients, there was no significant correlation between the residual concentration of cystatin C and the postoperative time (r = -0.098). CONCLUSIONS: The results suggest that in renal or liver transplant patients there is no formation of high molecular weight serum cystatin C-immunoglobulin complexes, regardless of the post-transplant period.

Adult↗

Pharmacological modification of the serotonergic transmitter system and beta-N-acetylhexosaminidase activity in rats.

The enzyme activity and activation energy of plasma beta-N-acetylhexosaminidase (Hex) was determined in rats whose serotonergic system had been pharmacologically altered. In the group of animals treated with 5-hydroxytryptophan, in the different dissected brain regions (brain stem, cortex and hippocampus) significantly higher levels of serotonin and 5-hydroxyindolacetic acid were found, and significantly lower in the group treated with p-chlorophenylalanine, than in the control group. In the total number of animals studied (n = 21), a statistically significant correlation was found between the plasma concentration of 5-hydroxyindolacetic acid and the levels of this metabolite in the different brain regions (p < 0.001). No significant differences were found for the activity of Hex in the plasma, or for its activation energy, which is a marker of its isoenzyme composition, among the three groups of animals. The results obtained using our experimental model in rats do not confirm the hypothesis of other authors who suggest that the Hex responds secondary to increases or decreases of serotonin turnover, and could be a biological test to monitor the serotonin status in psychiatric patients.

5-Hydroxytryptophan↗

Plasma beta-N-acetylhexosaminidase isoenzyme composition and temperature conversion factors.

Using the chromogenic substrate 3,3'-dichlorophenylsulfonphthaleinyl-N-acetyl-beta-D-glucosaminide for the activity determination of plasma beta-N-acetylhexosaminidase (Hex), the temperature conversion factors (TCF) offer a highly significant positive correlation with the relative proportion of Hex B isoenzyme (P< 0.001). The calculation of TCF 37 degrees/25 degrees C allows the isoenzyme composition of Hex to be determined quickly and cheaply. The results may be superimposed over those obtained in a previously described method based on the calculation of the enzyme's activation energy using four temperatures. However, the use of TCF 37 degrees/30 degrees C does not appear to comply with the required demands.

Autoanalysis↗

Comparison of predose vs 2-h postdose blood metabolites/cyclosporine ratios in kidney and liver transplant patients.

OBJECTIVES: It has recently been suggested that when adjusting doses of cyclosporine (CsA), determining its concentration in blood samples taken 2 h postdose (C(2)) is more clinically beneficial than using the predose concentration (C(0)). We determined C(0) and C(2) concentrations of CsA and their metabolites in samples taken from nine kidney and seven liver transplant patients. Similarly, the so-called metabolic ratios (MR)-metabolites to CsA parent ratios-were calculated to characterise the most suitable moment of blood sampling for obtaining a greater analytical specificity with monoclonal immunoassays. METHODS: The determination of CsA and CsA + metabolites was made using the enzyme multiplied immunotechnique and the polyclonal fluorescence polarization immunoassay Abbott TDx, respectively. RESULTS: The poor correlation between C(0) and C(2) of CsA (n = 82, r = 0.387, p < 0.001) is greatly inferior to that obtained between C(0) and C(2) of metabolites (n = 82, r = 0.912, p < 0.001). A highly significant difference (p < 0.001) was found between MR(0) values (mean 2.87 +/- 0.12, median 2.48) and MR(2) values (mean 1.73 +/- 0.09, median 1.46), although there is a good correlation between them (r = 0.878, p < 0.001). CONCLUSIONS: The extent of the positive bias (deviation) of CsA immunoassays compared with the high-performance liquid chromatography results is related to the MR values. As the MR(2) values are significantly lower than the corresponding MR(0), in practice a greater analytical specificity would be obtained with the different monoclonal immunoassays in the determination of the 2 h postdose CsA concentration than in that of trough concentration.

Biotransformation↗

Immunochemical and enzymatic study of ceruloplasmin in rheumatoid arthritis.

Forty adult patients (30 women and 10 men) with rheumatoid arthritis (RA), treated with nonsteroidal anti-inflammatory drugs, were studied. Serum levels of immunoreactive ceruloplasmin, oxidase activity of the ceruloplasmin and total copper, as well as the specific oxidase activity (enzyme activity per unit of mass) and the copper/immunoreactive ceruloplasmin relationship were significantly higher in the group of patients than in the healthy control group (p < 0.001). However, no significant difference was found for the concentration of non-ceruloplasmin copper between both groups. A statistically significant negative correlation was obtained for the concentration of serum thiobarbituric acid-reacting substances with the immunoreactive ceruloplasmin and its oxidase activity in the group of patients (p < 0.005). These results suggest that in RA increases of serum copper are produced at the expense of the fraction linked to the ceruloplasmin, diminishing the proportion of apoceruloplasmin and other forms poor in copper. Although the increase in the serum concentration of ceruloplasmin might offer an additional safeguard against oxidative stress. it does not appear to have a beneficial effect upon the activity of the illness as evaluated by means the biological inflammation markers C-reactive protein, erythrocyte sedimentation rate and sialic acid.

Adult↗

Relationship between plasma ammonia concentration and beta-N-acetylhexosaminidase isoenzyme activities in liver cirrhosis.

Ammonia is known to increase the secretion of beta-N-acetylhexosaminidase (Hex) to the extracellular medium in cultured human fibroblasts and Hep G2 cells. We examined 35 patients with liver cirrhosis and the results revealed a significant increase for the plasma activities of total Hex and its isoenzymes Hex A and Hex B (p < 0.001). The partial correlations, with other biochemical markers of liver injury constant, between plasma ammonia concentration and the activity (r = 0.658) and the proportion in percentage of the Hex B isoenzyme (r = 0.692) were statistically significant (p < 0.001). The increased concentration of ammonia could explain, at least partially, an increased secretion of Hex B isoforms to the plasma in patients with liver disease.

Adult↗

Specific oxidase activity of cord serum ceruloplasmin in the newborn.

In a study of 50 full-term newborns, we found serum levels of ceruloplasmin, its oxidase activity and specific oxidase activity (activity per unit mass of enzyme protein) which were significantly lower than in adult subjects (p<0.001). A significant correlation was obtained between the specific oxidase activity of the neonatal ceruloplasmin and the transferrin/alpha-fetoprotein ratio (p<0.01), which reflects the maturity of the fetal hepatocyte through its ability to synthesise fetal- and non-fetal-associated proteins. The lower specific oxidase activity of the ceruloplasmin in newborns would be due to a higher relative proportion of apoprotein, and/or other molecular forms with a poor copper content in the oxidase sites. This could be due to an inability to transfer copper into a common intracellular pool for holoceruloplasmin synthesis and biliary copper excretion. A high interindividual variability was found for the specific oxidase activity of the neonatal ceruloplasmin, and in the newborns with higher levels of ceruloplasmin this, from a catalytic point of view, is more similar to the adult form.

Adolescent↗

Thermodynamic characterisation of the mutated isoenzyme A of beta-N-acetylhexosaminidase in GM2-gangliosidosis B1 variant.

Here we report the determination of the activation energies of the plasma isoenzymes of beta-N-acetylhexosaminidase (Hex, EC 3.2.1.52), isolated by chromatography in DEAE-cellulose, using the neutral chromogenic substrate 3,3'dichlorophenylsulfonphthaleinyl-N-acetyl-beta-D-glucosaminide. The activation energy of mutated Hex A isoenzyme (Ea approximately 71.5 kJ/mol) from a patient with GM2-gangliosidosis B1 variant, homozygote for the G533-->A (Arg178His) mutation, was significantly higher than that of normal Hex A (Ea approximately 41.8 kJ/mol) and analogous to that of Hex B isoenzyme (Ea approximately 75.1 kJ/mol). The determination of this thermodynamic variable of Hex in different biological specimens could allow for a straightforward biochemical characterisation of the GM2-gangliosidosis B1 variant.

Child↗

Characterization of the isoenzyme profile of beta-N-acetylhexosaminidase in the urine of newborns.

The urinary isoenzymes of beta-N-acetylhexosaminidase (Hex) in newborn infants were characterised by chromatography, electrophoresis, thermodynamic analysis and through substrate specificity. No qualitative difference was found for the major Hex A and Hex B isoenzymes between full-term or premature newborns and adults, although in the latter group the relative proportion of Hex B is much lower (18.5 +/- 2.7% vs. 36.3 +/- 1.0%). An additional minor enzyme form was found in some premature newborns, which eluted from the DEAE-cellulose column at a higher concentration of NaCl than Hex A and, like this isoenzyme, is able to hydrolyse 4-methylumbellipheryl-2-acetamido-2-deoxy-beta-D-glucopyranoside-6 -sulphate, which would suggest that it has alpha subunits in its molecule. These results do not confirm the hypothesis of other authors about the existence of a unique fetal Hex isoenzyme in neonatal urine which eluted before the application of the NaCl gradient, similarly to the Hex B.

Adult↗

Assay of beta-N-acetylhexosaminidase isoenzymes in urine by means of determination of their activation energy without removing endogenous low-molecular-mass components.

The determination of the activation energy of beta-N-acetylhexosaminidase (Hex, EC 3.2.1.52), using 3,3'-dichlorophenylsulfonphthaleinyl-N-acetyl-beta-D-glucosaminide as substrate, allows its isoenzyme composition to be evaluated in different biological specimens. However, in the analysis of urine samples, it is necessary first to remove the endogenous low-molecular-mass components, as these provoke an over-estimation of the activation energy of the Hex and, consequently, of the relative proportion of Hex B isoenzyme. The study of this interference has allowed urea to be characterised as the only urinary metabolite that is responsible, and to establish a mathematical expression for the correction, in relation to the endogenous urea concentration, of the activation energy of the Hex obtained experimentally in samples of native urine. The results thus obtained for the isoenzyme composition of urinary Hex are similar to those found using an electrophoretic separation procedure.

Enzyme Activation↗

Assay of beta-N-acetylhexosaminidase isoenzymes in different biological specimens by means of determination of their activation energies.

The activation energy (Ea) of beta-N-acetylhexosaminidase (Hex, EC 3.2.1.52) was determined with 3,3'-dichlorophenylsulfonphthaleinyl-N-acetyl-beta-D-glucosaminide as substrate, with a much higher value being found for the Hex B isoenzyme (Ea = 75.1 kJ/mol) than for the Hex A isoenzyme (Ea = 41.8 kJ/mol). This fact allowed for the development of a fast and reliable thermodynamic method to determine the isoenzyme composition of Hex in different biological specimens (serum/plasma, saliva, cerebrospinal fluid, seminal plasma, urine, and leukocyte lysates). The results in serum given by the proposed method may be superimposed upon those obtained by the heat inactivation assay of O'Brien et al. (N Engl J Med 1970;273:15-20), and the catalytic activity calculated for Hex A offers a good correlation with that obtained by using the specific substrate 4-methylumbelliferyl-N-acetyl-beta-D-glucosaminide-6 sulfate (n = 25, r = 0.953).

Acetylglucosamine↗

Assay of serum/plasma beta-N-acetylhexosaminidase isoenzymes by heat inactivation using a continuous spectrophotometric method adapted to a centrifugal analyzer.

Activity of serum/plasma beta-N-acetylhexosaminidase (EC 3.2.1.52) was determined by means of a continuous spectrophotometric method using 3,3'-dichlorophenylsulphonphthaleinyl-N-acetyl-beta-D-glucosaminid e as substrate, with very satisfactory results. Incubation of an undiluted aliquot (1 ml) of samples at 52 degrees C for 8 hours with an adjusted pH 5.5-6.0 provoked only the inactivation of isoenzyme A, thus allowing the evaluation of beta-N-acetylhexosaminidase isoenzyme composition. In 25 serum samples from control subjects and pregnant women, a good correlation between the percentage of isoenzyme B obtained by this procedure and the fluorimetric assay of O'Brien et al. (New Engl J Med 1970; 273:15-20) was found (r = 0.983, S(yx) = 1.51), with no statistically significant difference between the means (43.2 vs 42.8%). In 84 healthy adult subjects, an average value of 30.3% for the proportion of isoenzyme B was obtained, with an interval of 25.4-35.0%, in agreement with results reported by other authors.

Adult↗

[Interconversion of the results for erythrocyte zinc protoporphyrin expressed in different units].

As stated in a recent document of the National Committee for Clinical Laboratory Standards (NCCLS Document C42-P, April 1995), expression of the results of erythrocyte zinc protoporphyrin (ZPP) in different units is a main source of confusion which may hamper the wide use of this test. The possible inter-conversion of the ZPP values expressed as microgram/g Hb, microgram/dL blood and microgram/dL red cells was assessed. It was found that in all cases, despite a good correlation between these values (r > or = 0.939), the error of the estimation was higher than allowed by the American College of Pathologists criteria. Such findings show that ZPP values expressed in different units cannot be inter-converted as a function of the corresponding regression equation. Similarly, the use of hematofluorometers with an analogic-digital converter to express results as microgram ZPP/ dL blood might pose an additional source of error.

Algorithms↗