PubMed Health⌕ Search

Biomedical subjects

J C Van Loon

Publications and source records attributed to J C Van Loon.

8 recordsLinked to original sources

Overview of analytical methods for elemental speciation.

This paper describes a selection of the major developments in the field of analytical methodology for elemental speciation over the period from January 1986 to December 1990. Methods for a number of elements will be highlighted. Judging by the number and diversity of published reports, there has been increasing interest and activity in the development of new and modified analytical methods. Further, it is very encouraging to observe the number of papers concerned with the accuracy and precision of such analytical methods, and with comparisons between two or more methods. Among electrochemical methods of analysis, anodic stripping voltammetry has provided an important basis for measurements of concentrations of labile metals in aqueous media. The fastest growing area of method development is the coupling of separation methods, usually chromatography, with a single- or multi-element detector. Most importantly, inductively coupled plasma mass spectrometry has recently been described as a very sensitive, multi-element detector. The success of a 'coupled' method is greatly dependent on a suitable interface. Several papers have been published recently describing useful interfaces. Chemical extraction procedures continue to occupy an important place. Applications of analytical elemental speciation methods have included environmental, biological, clinical and geological samples. A number of methods for elements most frequently studied will be discussed.

Animals↗

Release of metal ions from dental implant materials in vivo: determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue.

Little is known of the release of trace elements in vivo from dental implant materials. Conflicting data have been reported in the literature as to the levels of trace elements released and their potential consequences, mainly because of sampling and analytical methodological errors. In this study methods for average concentration levels of Al, Cr, Co, Mo, Ni, Ti, and V in organs were developed using rabbit tissue from an in vivo implantation study. At least 50% of the brain, liver, lung, kidney, and spleen were taken minimizing contamination. The tissue was homogenized by cryogenic milling at LN2 temperature and then freeze-dried. Samples were digested in nitric acid and hydrogen peroxide using microwave energy. Standard reference materials were utilized for quality control. One liver sample was analyzed 10 times to assess the method precision. Absorbance values in blanks, standards, and test samples were measured using a Varian GTA 95 graphite furnace and 875 spectrophotometer. Very satisfactory method precision and quality control were recorded. Low or very low levels of the trace elements were found in the various organs.

Alloys↗

Determination of chromium, cobalt and molybdenum in synovial fluid by GFAAS.

An artificial knee joint made of a cobalt alloy (Cr 27-38%, Mo 5-7%, others 9%, Co balance) failed in an orthopaedic patient with severe tissue reaction. Samples of synovial fluid and blood were analyzed for cobalt, chromium and molybdenum concentration using graphite furnace atomic absorption spectrophotometry (GFAAS). NIST SRM 909 Human Serum containing 91.3 micrograms/L chromium was used as the Cr Standard. To obtain reliable values for cobalt and molybdenum, three different independent analytical methods were employed to analyze each sample: 1) dilution of the samples with Triton TX-100 solution, followed by GFAAS; 2) microwave decomposition of the samples, followed by GFAAS; 3) classic nitric-perchloric acid decomposition of the samples, followed by GFAAS. The two decomposition methods were used to control the accuracy of the dilution method. The results showed that the non-decomposition method gave comparable results to the decomposition techniques for analysis of synovial fluid and blood. The data revealed that the patient had elevated levels of Co, Cr and Mo in both synovial fluid and blood with the values being 2-3 orders of magnitude higher in the synovial fluid from the affected knee.

Chromium↗