PubMed Health⌕ Search

Biomedical subjects

J C Wall

Publications and source records attributed to J C Wall.

At least 19 recordsLinked to original sources

Use of a multimemory stopwatch to measure the temporal gait parameters.

Before a measurement technique is used clinically, it must be shown to be both valid and reliable. The purpose of this paper was to investigate a novel technique for measuring the temporal phases of the gait cycle using a stopwatch and slow motion video. Two healthy, young adult subjects walked at a range of self-selected walking speeds on a resistive grid walkway. The subjects were videotaped while traversing the walkway. Using video played back at slow motion and a multimemory stopwatch, two student physical therapists independently analyzed the videotapes on five separate occasions. Regression analysis was used to compare the data obtained by each of the raters with those obtained from the walkway. Measurements by both raters correlated highly with those obtained from the walkway. The results indicated a slight bias between the walkway data and the stopwatch technique, but the confidence intervals suggest that the relative timing of key events differed by less than 1%. This study shows that it is possible to get valid and reliable measures of the relative durations of the temporal gait parameters using slow motion video and a multimemory stopwatch.

Adult↗

Deficiencies in standing weight shifts by ambulant hemiplegic subjects.

OBJECTIVE: To compare weight shifts of hemiplegic subjects with controls in parallel and diagonal stance. DESIGN: Case-control study. SETTING: All subjects were functionally independent in the general community. Hemiplegic subjects had qualified for and had received rehabilitation. PARTICIPANTS: Independently ambulant hemiplegic subjects, who exhibited an asymmetrical gait pattern, were compared with age-and sex-matched controls recruited from the same community. INTERVENTIONS: Subjects maintained a series of weight shift postures, each for a duration of 10sec, while standing on a transduced platform with feet both parallel and placed diagonally, the latter position designed to mimic the double support phases of the gait cycle. MAIN OUTCOME MEASURES: Locations of center of pressure (CP) were measured in relation to each subject's center of base of support and, ranges of weight shift in each direction were calculated. RESULTS: With feet parallel, the hemiplegic sample was deficient in shifting weight towards the hemiplegic leg and posteriorly (p<.05). The diagonal tests revealed deficiencies in shifting weight posterolaterally over both lower limbs (p<.05) but particularly over the affected leg. The ranges over which weight could be significantly below the values for the normal sample in both cardinal plane and diagonal directions (P<.05). CONCLUSIONS: Even functionally ambulant hemiplegic subjects demonstrate marked limitations in the capacity to shift weight and possess a reduced range of weight shift. The diagonal tests emphasized deficiencies in shifting weight posteriorly over both limbs and toward the affected side, specific rehabilitation of which may improve gait.

Adult↗

A comparison of the range of walking speeds between normal and hemiplegic subjects.

It is known that people who have suffered stroke walk slower than normal. However, their ability to deviate from a preferred speed of walking has not been reported. This study investigated the range of walking speeds of 20 hemiplegic subjects and compared the results with those of 20 normal age- and gender-matched controls. All subjects traversed a computerized grid walkway which measured selected temporal and spatial gait parameters. Subjects walked at five self-selected speeds: "normal"; "slower than normal"; "slowest"; "faster than normal"; and "fastest". Comparisons were made between velocity, range of velocity, stride time and stride length. The hemiplegic group walked significantly slower at all speeds, were less capable of adapting the speed of their gait, possessed a markedly reduced range of walking speed, and walked more cautiously than the controls. These deficiencies are likely to limit the stroke person's ability to respond to environmental demands.

Adult↗

Combining new technologies for effective collection development: a bibliometric study using CD-ROM and a database management program.

Librarians have used bibliometrics for many years to assess collections and to provide data for making selection and deselection decisions. With the advent of new technology--specifically, CD-ROM databases and reprint file database management programs--new cost-effective procedures can be developed. This paper describes a recent multidisciplinary study conducted by two library faculty members and one allied health faculty member to test a bibliometric method that used the MEDLINE and CINAHL databases on CD-ROM and the Papyrus database management program to produce a new collection development methodology.

Bibliometrics↗

The kinematics of idiopathic gait disorder. A comparison with healthy young and elderly females.

In this study the kinematic gait parameters of healthy young and elderly subjects were compared with those of a group of patients with idiopathic gait disorder of the elderly (IGDE), a condition characterized by dysfunctional walking for which no underlying cause can be determined. The velocity and the temporal/distance gait kinematics were measured for self-selected fast, medium and slow speeds of walking. The elderly walk with a more cautious gait pattern than younger adults. This pattern is characterized by a slow walking speed and a reduced single support phase, with shorter but more frequent strides, and is even more marked in persons with IGDE. The slower the walking speed the more cautious this pattern becomes. The patients with IGDE not only walk far slower than a group of healthy age matched individuals but the range of speeds, from self-selected slow to fast, is much reduced and does not overlap that of the healthy elderly. With objective gait measurements this group might be better identified.

Adult↗

Measurement of the temporal and spatial parameters of gait using a microcomputer based system.

This paper describes a system for measuring the temporal and spatial parameters of gait. The basis of the system is a resistive grid walkway which is controlled by a microcomputer which also collects, processes and stores the data from the walkway. The data obtained from the system, including the temporal and spatial parameters of gait such as step and stride lengths, the durations of swing and support phases of the gait cycle and walking speed, are presented in both numerical and graphical forms. Accuracy to within 1 cm has been verified by analysing videotapes of foot placement during a walk. Special emphasis has been placed on making the system software user-friendly. The presentation of date uses several types of display, from a simple graphical summary of the walk statistics to a more complete report showing all the data from each stride. In the year during which the walkway system has been operational, it has been found easy to use by both subjects and operators, and it produces very useful data.

Biomedical Engineering↗

Gait asymmetries in residual hemiplegia.

Temporal gait asymmetries in 25 patients with residual stroke were measured from a walkway which allowed data collection on-line with a microcomputer. An asymmetry ratio has been introduced to reflect the degree of asymmetry in each of the support phases of the gait cycle. Subjects in this study demonstrated residual deficits in walking, and although there was a general pattern of asymmetry, walking patterns varied even though the group had been selected according to criteria which tended to make for relative functional homogeneity. Both the extent and patterns of temporal gait asymmetries with respect to phases of the gait cycle were found to vary. The basic rehabilitative implication of these findings is that it is not possible to design a single gait reeducation program for all residual stroke patients; the exercises prescribed must address the unique deficiencies of each patient.

Aged↗

Two-dimensional isoelectric focussing/sodium dodecyl sulphate polyacrylamide gel electrophoretic mapping and some molecular characteristics of the proteins of the adult guinea-pig small intestinal microvillus membrane.

The adult guinea-pig small intestinal microvillus membrane was purified approximately 25-fold by both cation-precipitation and differential centrifugation methods. Comparison by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) revealed no substantial differences in polypeptide composition between the two preparations. One-dimensional SDS-PAGE and two-dimensional isoelectric focussing (IEF)/SDS-PAGE, together with Coomassie-blue, silver and lectin-staining, showed three major high molecular weight polypeptides, Mr 108 000, 116 000 and 127 000, as well as a 47 kDa protein (actin), as major constituents of the membrane. The proteins of Mr 108 000 and 116 000 were strongly concanavalin A reactive. A detailed two-dimensional IEF/SDS-PAGE map of the membrane was constructed. Sodium carbonate treatment showed the two concanavalin A-reactive glycoproteins, Mr 108 000 and 116 000, comprising the sucrase-isomaltase complex, to be loosely-associated 'extrinsic' microvillus membrane proteins. Two proteins, Mr 127 000 and 135 000, were tightly-associated 'intrinsic' microvillus proteins. Despite regional differences in specific activity of some small intestinal microvillar enzymes, most noticeably enterokinase (EC 3.4.21.9) and dipeptidyl peptidase IV (EC 3.4.14.x), no substantial regional differences were seen in microvillus membrane polypeptide composition. In contrast, a substantial increase in the major high molecular weight proteins of Mr 108 000 and 116 000 accompanied a 10-fold rise in sucrase-isomaltase activity, and loss of a major protein of Mr 131 000 accompanied the complete loss of lactase activity from the membrane during postnatal development.

Age Factors↗

A microcomputer-based system for measuring temporal asymmetry in amputee gait.

This paper reports the development of a microcomputer-based system for measuring the temporal factors of amputee gait. The system has been designed for possible use in a standard clinical environment. It consists of a simple walkway, two photoelectric beam relays, a control unit and an APPLE II Plus microcomputer. Preliminary clinical assessment of the system has been conducted. The gait characteristics of eight amputees during their ambulation training were investigated with the use of the new system. A comparison of the results from different groups of subjects, selected primarily on level of amputation, is presented.

Aged↗

Pliocene hominid gait: new interpretations based on available footprint data from Laetoli.

Normative trends in the gait patterns of modern man can be used to reconstruct crucial characteristics of the bipedal behaviour of Pliocene hominids from their fossilized footprints. In this reconstruction the interrelated parameters of velocity, stride-length, and cadence are determined from imprints made in damp volcanic ash some 3.7 million years ago. When early hominid footprint data is fitted to regression equations of high predictability for the interrelationship of these locomotor parameters in modern man, a pattern of gait emerges that contradicts previous reconstructions.

Adult↗

Age-related changes in the orientation and particle size of the mineral phase in human femoral cortical bone.

It has previously been observed that after the third decade of life the tensile strength of bone decreases faster than its density [1], indicating that some microstructural change occurs in bone with advancing age. In order to try to elucidate this observation, the orientation and particle size of the mineral phase of bone have been studied with respect to age. Samples were taken from femora varying in age from 13 to 97 years. The results show that the degree of preferred orientation does not vary with age after the first decade of life. However, the percentage of small particles increased up to the fourth decade of life and thereafter decreased, a pattern of change similar to that observed for bone strength. It would seem to indicate that an increase in mineral particle size is a factor that contributes to the loss of bone strength and that an increased percentage of bone strength and that an increased percentage of large particles in the later years of life could, along with osteoporosis, help to explain the increased fragility in the bones of the elderly.

Adolescent↗

Gait analysis in the assessment of functional performance before and after total hip replacement.

A method which measures the temporal and distance factors has been employed to monitor the gait of patients one week prior to total hip replacement and six and twelve months after operation. Variables have been selected which reflect gait symmetry and others which slow the speed of walking and how this is achieved. The method of presentation of results is discussed with particular attention to the use of these results in monitoring the progress of the patient. As a group these patients showed the greatest improvement of six months after operation with little added improvement shown at twelve months.

Female↗