PubMed Health⌕ Search

Biomedical subjects

J Chris Buckland-Wright

Publications and source records attributed to J Chris Buckland-Wright.

4 recordsLinked to original sources

Risedronate decreases biochemical markers of cartilage degradation but does not decrease symptoms or slow radiographic progression in patients with medial compartment osteoarthritis of the knee: results of the two-year multinational knee osteoarthritis structural arthritis study.

OBJECTIVE: Bisphosphonates have slowed the progression of osteoarthritis (OA) in animal models and have decreased pain in states of high bone turnover. The Knee OA Structural Arthritis (KOSTAR) study, which is the largest study to date investigating a potential structure-modifying OA drug, tested the efficacy of risedronate in providing symptom relief and slowing disease progression in patients with knee OA. METHODS: The study group comprised 2,483 patients with medial compartment knee OA and 2-4 mm of joint space width (JSW), as determined using fluoroscopically positioned, semiflexed-view radiography. Patients were enrolled in 2 parallel 2-year studies in North America and the European Union. These studies evaluated the efficacy of risedronate at dosages of 5 mg/day, 15 mg/day, 35 mg/week (in Europe), and 50 mg/week (in North America) compared with placebo in reducing signs and symptoms, as measured by the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index and patient global assessment (PGA) scores, and in slowing radiographic progression. RESULTS: A reduction of approximately 20% in signs and symptoms, as measured by WOMAC subscales and PGA scores, was observed in all groups, with no treatment effect of risedronate demonstrated. Risedronate did not significantly reduce radiographic progression as measured by decreased JSW or using a dichotomous definition of progression (joint space loss of >or=0.6 mm). Thirteen percent of patients receiving placebo demonstrated significant disease progression over 2 years. A dose-dependent reduction in the level of C-terminal crosslinking telopeptide of type II collagen, a cartilage degradation marker associated with progressive OA, was seen in patients who received risedronate. No increase in the number of adverse events was demonstrated for risedronate compared with placebo. CONCLUSION: Although risedronate (compared with placebo) did not improve signs or symptoms of OA, nor did it alter progression of OA, a reduction in the level of a marker of cartilage degradation was observed. A sustained clinically relevant improvement in signs and symptoms was observed in all treatment and placebo groups.

Adult↗

Relationships between tibial rim alignment and joint space width measurement reproducibility in non-fluoroscopic radiographs of osteoarthritic knees.

RATIONALE: Superimposition of the rims of the medial tibial plateau to within 1mm is an aim of fluoroscopic knee positioning protocols for osteoarthritic (OA) knee radiography and has also been proposed as a measure of quality for non-fluoroscopic methods. OBJECTIVE: To evaluate the effect of tibial rim alignment (TRA) on reproducibility of joint space width (JSW) measurement, both were measured from radiographs taken with each tibial plateau at a range of angles determined by different non-fluoroscopic views. METHODS: TRA and JSW measurements were taken from both knees of 100 OA patients each radiographed in fully extended, schuss/tunnel, and MTP views. Degree of TRA was compared with JSW reproducibility using correlation, and between groups defined both by the 1mm threshold and by TRA-defined quartiles. RESULTS: JSW reproducibility was dependent on the degree of TRA in the fully extended and schuss/tunnel flexed knee views, although the use of the specific TRA threshold of 1mm was not supported. In the MTP view, JSW measurement was found to be highly reproducible across the full range of TRA values. CONCLUSION: These results contradict claims that TRA to within 1mm is essential for useful measurement of JSW. It is an arbitrary threshold, of use in quality control (QC) for protocols which explicitly require such alignment, and the choice of QC criteria for other protocols should be evaluated on a view-by-view basis. The results confirm previous studies showing the MTP view to afford highly reproducible JSW measurement.

Aged↗

Reproducibility of the semiflexed (metatarsophalangeal) radiographic knee position and automated measurements of medial tibiofemoral joint space width in a multicenter clinical trial of knee osteoarthritis.

OBJECTIVE: To determine the baseline and longitudinal consistency in reproducibility of the semiflexed metatarsophalangeal (MTP) position in repeat examinations of patients with knee osteoarthritis (OA) recruited for a multicenter clinical trial that terminated within one year (mean duration 0.81 yr), based on precise measurements both of minimum medial tibiofemoral compartment joint space width (JSW) and of tibial inter-rim distance. METHODS: Two technologists from 8 and one technologist from 14 clinical radiology units had received previous training in performing nonfluoroscopic semiflexed MTP knee examinations and in quality control criteria for film acceptance. Patients (N = 402; F = 269) were recruited from 58 rheumatology sites and referred to 22 centers, or "x-ray hubs," across North America. At baseline and at study exit, both knees were x-rayed twice on the same day. All films had quality control, and accepted films were digitized at the Central Radiographic Facility and transmitted to the Central Analysis Facility for computerized measurement of minimum medial compartment JSW and tibial inter-rim distance. JSW loss was calculated in the placebo group for the study period. RESULTS: The median SD of the difference in JSW between same-day test/retest film pairs was 0.9 mm for 767 baseline film pairs (knees with JSW > 0 mm), and 0.08 mm for 631 exit film pairs. JSW reproducibility was unaffected by subject's sex, age, and degree of JSW loss. Among all x-ray hubs, JSW reproducibility was excellent in 14 (SD < 0.1 mm), good in 6 (0.1 < SD < 0.2 mm), and moderate in 2 hubs (0.2 < SD < 0.3 mm). No statistical difference was found in technologists' ability either in positioning OA knees or in their test/retest reproducibility in repositioning joints at baseline and at study exit. JSW did not alter significantly during the study period. CONCLUSION: The protocol for the semiflexed MTP knee position provides a highly reproducible method for anatomically repositioning the knee and for measuring JSW, necessary for OA clinical trials. It is a simple method that can be employed readily at clinical radiology units, as shown by the similarity in JSW precision between x-ray hubs. The results from this large dataset show that throughout the study precise measurements of JSW were obtained from same-day repeat radiographs, findings that together with previous single-center studies confirm the reliability of this method for clinical trial use.

Arthrography↗

X-ray technologists' reproducibility from automated measurements of the medial tibiofemoral joint space width in knee osteoarthritis for a multicenter, multinational clinical trial.

OBJECTIVE: To determine the reproducibility of x-ray technologists, 26 in North America (NA), 24 in Europe (EU), in reliably repositioning patient's osteoarthritic (OA) knees, from computerized measurements of minimum joint space width (JSW) and reproducibility in joint repositioning, during their training for the clinical trial. METHODS: Technologists from 12 NA and 12 EU clinical radiology units received identical training, at one site on each continent, in performing the fluoroscopically assisted semiflexed knee examination and in quality control criteria (QCC) for film acceptance. Subjects recruited were 129 in NA and 70 in EU, with both knees radiographed for some subjects. Each technologist radiographed 5 OA knees and repeated the process on the same knees 2 to 7 days later. Minimum medial JSW was measured at a single center on digitized images with computer software that corrected for radiographic magnification. Technologists' reproducibility in joint repositioning and JSW measurement was determined from the difference between test and retest. RESULTS: In all, only 3/50 technologists failed qualification criteria with a repeat-film JSW difference > 0.50 mm. The mean, standard deviation (SD) of the difference in JSW between test/retest for 146 NA film-pairs of -0.020 (0.16) mm was not statistically different from that in 120 EU film-pairs: -0.001 (0.18) mm. In NA and EU 45% of examinations achieved high quality, i.e., JSW difference between repeat films < 0.1 mm, and 92% achieved excellent to good quality with a difference between repeat films < 0.3 mm. NA and EU technologists' reproducibility was unaffected by subject's sex, age, and degree of JSW loss. Reproducibility in joint reposition for all technologists was excellent. CONCLUSION: Between-continent precision of JSW measurements from all accepted pairs of semiflexed views was excellent to very good and similar to the high technical quality achieved in the authors' original report. The value of training incorporating both test/retest radiographs and film QCC is essential for the high technical quality required for multinational clinical trials.

Adult↗