PubMed Health⌕ Search

Biomedical subjects

J Conze

Publications and source records attributed to J Conze.

At least 19 recordsLinked to original sources

[Management of recurrent inguinal hernia after previous mesh repair: a challenge].

INTRODUCTION: Since the use of prosthetic mesh for the surgical repair of inguinal hernias has become increasingly popular, mesh material introduced during a previous operation is being detected in a growing number of patients undergoing surgery for recurrent hernia. This applies to at least 10% of recurrences. Needed is a therapeutic algorithm for the surgical management of recurrent hernias after previous mesh repair. MATERIAL AND METHODS: A total of 672 recurrent hernia repairs performed in hospitals in the German cities Aachen and Koblenz were analysed in order to review clinical practice. In 92 patients (13.7%) who underwent surgery for recurrent hernia, mesh had been used in the previous hernia repairs. Attention was focused on the location of the recurrence in relation to the site of mesh implantation and on the advantages and disadvantages of the various surgical procedures for repairing recurrent hernias. Re-examination was performed with a mean follow-up of 3 years. RESULTS: Surgeons mostly decided during operation which procedure to use. A transinguinal approach was preferred for patients presenting with recurrent hernia and pain, and mesh material introduced during a previous operation was then explanted. In the case of multiple recurrences, a minimal direct suture repair was used for small defects or a preperitoneal approach for inserting a new, large mesh. The majority of recurrences were medial or suprapubic, especially those occurring after a Lichtenstein repair. After re-examining 87 of 92 patients, nine recurrences (10.3%) were found. Mesh-free suturing methods were affected most frequently. Moderate complaints were reported by 39.1%, and 4.6% suffered from medical chronic pain. CONCLUSION: The surgical management of recurrent hernias after previous mesh repair is a particular challenge for surgeons. We introduce a therapeutic algorithm for recurrent hernia surgery after previous mesh implantation based on analysis of clinical practice.

Adult↗

Incisional intercostal hernia after a nephrectomy.

The aim of the present case report is to present the diagnostic and therapeutic challenge of intercostal incisional hernia. We report on a female patient with leftsided intercostal incisional hernia between the eleventh and twelfth rib due to preceding lumbar incision for tumor nephrectomy. Because of its infrequence, diagnosis was established late although simple clinical examination and ultrasound investigation displayed the hernia. At laparotomy, a 5x5 cm(2) fascial defect with a colonic sliding hernia was found. Hernia repair using permanent mesh reinforcement in the retromuscular position is described. Abdominal incisional hernia in the intercostal region is rare and therefore easily overlooked. As with other incisional hernias, the hernia repair using mesh implantation in the retromuscular region is technically feasible and represents the treatment of choice.

Hernia, Ventral↗

Intraabdominal adhesion formation of polypropylene mesh. Influence of coverage of omentum and polyglactin.

BACKGROUND: Adhesions after intraabdominal surgical procedures are related to high morbidity and mortality. Biomaterials, particularly those made of polypropylene, in the intraabdominal position have to be considered as pathophysiological cofactor in a multifactorial process of adhesion formation. To investigate the adhesive potential induced by the biomaterial, an animal model was performed. In addition, the influence of coverage by omentum or a polyglactin barrier was investigated. METHODS: In, 18 Chinchilla rabbits the biomaterial was placed laparoscopically using the intraperitoneal onlay mesh technique. Using this model, a polypropylene-polyglactin mesh compound (PPMC) was used with three different implantation techniques: group 1, PPMC implantation without coverage (PPMC): group 2, PPMC implantation with additional omentum coverage (PPMC-O): and group 3, PPMC implantation with coverage of an absorbable polyglactin mesh (PPMC-V). The degree of adhesion formation was measured 90 days after implantation by computer-assisted planimetry. Morphometric examination followed the explantation analyzing the amount of foreign body response. RESULTS: We found a significant reduction of adhesion formation for the PPMC and PPMC-O groups compared to the PPMC-V group, in which dense adhesions were found. Morphometric investigations of the perifilamental granulomas of the pure (PPMC) group revealed a typical foreign body reaction with a mild to moderate fibrosis around all mesh fibers. However, tissue specimens of the PPMC-O and PPMC-V groups indicated a similar inflammatory reaction but significantly increased connective tissue formation around the polymer fibers compared to the pure PPMC group. CONCLUSION: The intraabdominal placement of a pure PPMC shows a neoperitonealization and perifilamental collagenous ingrowth with almost no adhesions. Coverage with omentum (PPMC-O) or polyglactin mesh (PPMC-V) resulted in a significant increase in inflammation and perifilamentary connective tissue formation.

Animals↗

Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair.

BACKGROUND: Polymer mesh has been used to repair incisional hernias with lower recurrence rates than suture repair. A new generation of mesh has been developed with reduced polypropylene mass and increased pore size. The aim of this study was to compare standard mesh with new lightweight mesh in patients undergoing incisional hernia repair. METHODS: Patients were randomized to receive lightweight composite mesh, or standard polyester or polypropylene mesh. Outcomes were evaluated at 21 days, 4, 12 and 24 months from patient responses to the Short Form 36 (SF-36) and daily activity questionnaires. Complications and recurrence rates were recorded. RESULTS: A total of 165 patients were included in an intention-to-treat analysis (83 lightweight mesh, 82 standard mesh). Postoperative complication rates were similar. The overall hernia recurrence rate was 17 per cent with the lightweight mesh versus 7 per cent with the standard mesh (P = 0.052). There were no differences in SF-36 physical function scores or daily activities between 21 days and 24 months after surgery. CONCLUSION: The use of the lightweight composite mesh for incisional hernia repair had similar outcomes to polypropylene or polyester mesh with the exception of a non-significant trend towards increased hernia recurrence. The latter may be related to technical factors with regard to the specific placement and fixation requirements of lightweight composite mesh.

Activities of Daily Living↗

[Incisional hernia].

With a long-term incidence of 10-20%, incisional hernias remain one of the most common surgical complications. Beside technical causes, wound-healing problems are increasingly being discussed. Conventional suture repair shows disappointing results and should be used only in selected cases. By the implantation of mesh prostheses, notable improvement could be achieved, with recurrence rates of <10%. Its main principle is retromuscular mesh reinforcement of the entire scar. Particularly in the neighbourhood of osseous structures, only retromuscular placement allows sufficient subduction of the mesh by healthy tissue of at least 5 cm in all directions. Preparation must take into account the special anatomic features of the abdominal wall, especially in the area of the Linea alba and Linea semilunaris.

Abdominal Wall↗

Technical consideration for subxiphoidal incisional hernia repair.

BACKGROUND: The main principle of incisional hernia repair with mesh augmentation is a wide overlap of at least 5 cm in all directions. This is complicated when cartilaginous or osseous structures border the fascial defect, most notably at the xiphoid after sternotomy or in large proximal incisional hernias. METHOD: We performed an anatomic investigation of this "problematic" area with its different structures and layers that form the retroxiphoidal space. RESULTS AND CONCLUSION: The posterior lamina of the rectus sheath inserts on the posterior side of the xiphoid. This lamina inhibits a sufficient mesh placement. By sharp dissection dorsal the xiphoid process, the posterior lamina of the rectus sheath can be detached. This way the retroxiphoidal space can be opened. Further development of this space can be made by blunt dissection. In some cases, with retroxiphoidal scar formation after sternotomy, a sharp dissection might be necessary. This enables a combined retromuscular-retroxiphoid mesh augmentation repair with a sufficient underlay of at least 5 cm, according to the principles of sublay technique.

Cadaver↗

Pitfalls in retromuscular mesh repair for incisional hernia: the importance of the "fatty triangle".

Open retromuscular mesh repair has become a standard procedure in incisional hernia repair. This technique led to a significant decrease of recurrences. Recurrences after this technique typically occur at the upper mesh border and are a result of the technical complexity of reaching the postulated underlay of 5 cm in the region of the linea alba. We performed an anatomical study in human corpses to investigate the abdominal wall with its different structures, with emphasis on the overlap of the mesh under the linea alba. The overlap can be achieved by incision of the posterior lamina of the rectus sheath, on both sides close to the linea alba. The incision opens the preperitoneal space and appears in the shape of a "fatty triangle". The anterior lamina of the rectus sheath above the hernia defect remains intact and facilitates a sufficient thrust bearing for a retromuscular mesh implantation. Knowledge of the anatomy and preparation of the "fatty triangle" enables a mesh positioning according to the principles of retromuscular mesh repair.

Abdominal Muscles↗

The Pfannenstiel or so called "bikini cut": still effective more than 100 years after first description.

The original Pfannenstiel incision is discussed including the technique, history, current indications, advantages, and disadvantages. Excellent cosmetic results, principles of less traumatic surgery, and a rare incisional hernia complication rate of about 0-2%, as well as long-time use characterise this access path to the pelvic organs first described by the German gynaecologist in 1900. Complications of nerve damage, however, should be recognised, especially when extending the incision too far laterally.

Female↗

[Foreign body-induced disruption of the gastrointestinal tract-anatomy of the ileocoecal opening].

INTRODUCTION: Over 75% of ingested foreign bodies pass the gastrointestinal tract without any complications. Blunt foreign bodies may lead to a disruption of the intestinal passage, mainly in the area of the ileocoecal opening. The size of the reported foreign bodies varies considerably. The aim of this study was the anatomic investigation to clarify the possible causes of obstruction and its influence on the diameter of the ileocoecal opening. MATERIAL AND METHOD: We investigate anatomically and describe the ileocoecal opening on the basis of 27 specimens. RESULTS: We found not a flap mechanism but a valve mechanism in the ileocoecal junction. The median diameter of the formalin-fixated specimens was 10.9 mm respectively 21.8 mm according to an assumed correction factor of 2. The cause for intestinal obstruction most probably is the ingestion of blunt, angular foreign bodies in the ostium ileale. CONCLUSION: The intraindividual differences as well as the considerable size of foreign bodies that pass the ileoceocal opening support the hypothesis, that the complications described are more a consequence of an ingestion of blunt, cornered foreign bodies in the ostium ileale independent ofn the size of the ileocoecal opening itself.

Cecum↗

Polypropylene in the intra-abdominal position: influence of pore size and surface area.

BACKGROUND: Polypropylene is a material widely used in surgery. Because of its association with formation of enterocutaneous fistulae and adhesions, direct contact between mesh and intestine is avoided. The following study was designed to investigate the adhesive potential of different polypropylene meshes when placed in direct contact with intestine. MATERIAL AND METHODS: In an established experimental model, a total of 45 chinchilla rabbits underwent laparoscopic placement of meshes with different pore size (Group I: monofilament PP 0.6 mm, Group II: monofilament PP 2.5 mm, Group III: multifilament PP 4.0 mm) with the Intra-Peritoneal-Onlay-Mesh Technique (IPOM). The degree of adhesion formation was measured after 7, 21, and 90 days, evaluated by an adhesion score, quantified by computer-assisted planimetry, followed by histological and morphometric investigation of the perifilamental granuloma formation. RESULTS: The heavyweight, small porous polypropylene meshes (PP 0.6) showed significantly stronger adhesion formation at all intervals of investigation compared with the lightweight meshes with a pore size >2.5 mm. Between the two different lightweight mesh variations, there was no significant difference. Granuloma formation was lowest in large-pore-size monofilament meshes (PP 2.5). CONCLUSION: The IPOM rabbit model is suitable for investigation of biomaterials in the intra-abdominal position. Our results show that the adhesive potential is significantly influenced by the pore size. However, the extent of the foreign-body reaction seems also to be influenced by the filament structure, respectively, the surface area, favoring monofilament material.

Abdominal Cavity↗

Venocutaneous fistula.

This is the first description of venocutaneous fistula, a late complication of elective laparoscopic cholecystectomy that arose 18 months after the initial operation. Postoperatively, the patient twice developed an abscess in the abdominal wall at the former site of the umbilical trocar. The first abscess occurred on the 6th postoperative day; the second, after 14 months. After an additional 4 months, a fistula opening appeared just below the umbilicus. Fistulography revealed a connection with the venous system of the omentum majus. During subsequent resection of the fistula, a pigment gallstone was retrieved from the base of the fistula.

Abdominal Abscess↗

[Partial intestinal obstruction after swallowing a self-expanding sponge for weight reduction].

HISTORY AND ADMISSION FINDINGS: A 21-year-old woman presented with predominantly right-sided cramp-like abdominal pain which had started the previous day. The abdomen was soft on palpation, the peristaltic sounds increased. Body temperature was normal. INVESTIGATIONS: Routine laboratory tests were unremarkable, including white cell count (4.5 G/l). and C-reactive protein. TREATMENT AND COURSE: She was admitted to hospital for observation. Because the symptoms persisted she underwent a right lower laparotomy because acute appendicitis was suspected. Intraperitoneal examination of the intestines revealed a soft, sponge-like foreign body just above the ileocecal valve. The overlying ileum was incised and a sponge removed. Postoperatively the patient reported having taken 4 capsules of CM3, a weight-reducing preparation, about 14 days ago. These capsules dissolve in the stomach and each releases a small sponge which expands and mechanically induces a feeling of satiation. The further course was unremarkable and she was discharged on the 8th postoperative day. CONCLUSION: When producing weight-reducing preparations that act according to physico-mechanical principles, anatomical circumstances should be considered, and they should only be taken under medical supervision.

Abdominal Pain↗

Impact of polymer pore size on the interface scar formation in a rat model.

BACKGROUND: The surgical therapy of hernias is increasingly based on reinforcement with alloplastic material, in particular surgical meshes. The biological response to these foreign bodies largely depends on the selected material and its structure. In comparison to the physiological scar process following a simple abdominal wall incision, the chronic inflammation at the interface to the polymers lead to specific morphological alterations. MATERIALS AND METHODS: In the present study two meshes with different pore sizes were implanted into rats: a heavy-weight and small-pore-sized mesh (hw-mesh) made of nonabsorbable polypropylene monofilaments and a low-weight large-pore-sized mesh consisting of polypropylene and of absorbable polyglactin multifilaments (lw-mesh). A suture repair of a laparotomy served as control. After 7, 14, 21, and 90 days the mesh area was analyzed with regard to tissue and cellular response. RESULTS: Over the whole observation period morphometric analysis indicated an improved integration of the lw-mesh with reduction of both inflammation and fibrosis, whereas the hw-mesh induced an intense chronic inflammation concomitant with an intensified bridging scar reaction. On the cellular level these findings correspond to an elevated cell turnover, characterized by increased rates of apoptotic and proliferating cells. In contrast, the tissue reaction to the lw-mesh achieved levels almost similar to those of the physiological scaring process in the control group. CONCLUSION: In conclusion, the present data confirm the development of a chronic inflammatory foreign body reaction at the interface to both hw-meshes and lw-meshes; however, the use of lw-meshes showed superior tissue integration. With regard to the quite similar polymer surface the pore size appears to be of major importance in tissue reaction and for the biocompatibility of mesh structures.

Animals↗

[Leiomyosarcoma of the hernial sac in inguinal hernia].

Malignant tumors associated with hernial sacs are rare entities. A review of literature offers only small groups of patients. The high incidence of inguinal hernia repair operations demands recognition of this morbidity. It should be suspected in cases of tight tissue in the hernial sac in differentiation to the unreduced inguinal and femoral hernia. Therapy of choice must be a resection in toto (R0), incomplete resection causes inguinal spreading or recurrence of the tumor. The exact evaluation of the surroundings should follow. There is no other standardized therapy besides operation. A case of leiomyosarcoma in inguinal hernia will present the entity of neoplastic disease in hernial sac.

Abdominal Neoplasms↗

Uptake of cis-4-[18 F]fluoro-L-proline in scar formation: a marker of collagen synthesis?

Excessive scar formation is accompanied by abnormal collagen synthesis. The feasibility of monitoring collagen synthesis in vivo with no-carrier-added cis-4[18F]fluoro-L-proline (cis-FPro) was evaluated in an animal model with scar formation induced by implanted meshes. The abdominal wall of rats was replaced by alloplastic meshes. At days 3, 7, 14, 21 and 90 after implantation, the uptake of cis-FPro at 4 h post-injection was determined for resected samples of the mesh and normal tissues. The highest uptake was found in the kidneys (1.73+/-0.47%ID/g) followed by the liver (0.59+/-0.19%ID/g). The meshes showed the maximum uptake at day 3 (0.20+/-0.07%ID/g) with a decrease to 0.10+/-0.03%ID/g at day 90 (P<0.001). After 3 days no connective tissue was shown by histopathological morphometric analysis. The maximum partial volume (PV%) of connective tissue was 43+/-14 PV% 90 days after implantation. The maximum levels of granulocytes and inflammatory infiltrate were found at day 3 with minimal levels at day 90, paralleling the course of cis-FPro uptake. In conclusion, the uptake of cis-FPro at 4 h post-injection is not related to the content of connective tissue. Cis-FPro radiolabelled with 18F appears not to be a suitable radiopharmaceutical for in vivo monitoring of collagen synthesis in scar formation.

Abdominal Wall↗

Inguinal tensile strength and pain level after Shouldice repair.

BACKGROUND: Tension of the abdominal wall in the inguinal region induced by Shouldice repair of an inguinal hernia is said to be responsible for elevated postoperative pain levels. PATIENTS AND METHODS: In 20 patients we recorded the inguinal tensile strength during closure of the hernial gap using a wound retractor equipped with strain gauges. Postoperative pain levels were scaled using a visual analogous score, and correlated with the tensile strength of the inguinal abdominal wall together with peak flow and forced expiratory volume in 1 s (FEV1) 8, 24, and 48 h after the time of operation. RESULTS: Shouldice repair caused an average increase in inguinal tensile strength of 2.9 +/- 0.58 N (mean +/- SEM). The pain level expressed by active patients was twice the value obtained from resting patients (41.55 +/- 6.3% vs 20.81 +/- 7.1% 8 h after operation), but decreased slightly later on. Peak flow during forced expiration was depressed to about 80% of the control values, whereas the 1-s volume during forced expiration decreased only to 95% of the control value. We excluded any correlation between the recorded individual inguinal tensile strength or the changes in distance between the lateral edge of the rectus sheath and the base of the inguinal ligament and the postoperative pain level. CONCLUSION: We failed to see any evidence for the hypothesis that higher inguinal tensile strength induced by Shouldice repair leads to an elevated level of postoperative pain. If there is any effect, it may be masked by other factors with a stronger influence.

Abdominal Muscles↗

[Intraoperative measurement of suture forces in Shouldice repair of primary inguinal hernias].

A special instrument was developed in order to quantify intraoperatively the traction forces which are employed during Shouldice repair of a primary inguinal hernia while adapting the lateral edge of the rectus sheath and the iliopubic tract. Further investigations were performed under the Valsalva manoeuvre and simultaneous measurement of the intra-abdominal pressure. In 25 patients an average increase in traction forces of 3.62 +/- 0.60 N was registered when the hernial gap was decreased to 0.3 cm. By applying the Valsalva manoeuvre with an average increase of 32 mm Hg in intra-abdominal pressure, traction was increased by a further 1.67 +/- 0.20 N on average. Hernia repair, tensing of the abdominal muscles and increasing the intra-abdominal pressure, however, have a small effect on the traction forces affecting the edges of the hernial gap. It may therefore be concluded that these factors, frequently believed causal for early hernia recurrence, are actually less influential as the force vector stressing the repair zone points in a different direction.

Adult↗