PubMed Health⌕ Search

Biomedical subjects

J Cowie

Publications and source records attributed to J Cowie.

16 recordsLinked to original sources

Specific proliferative T cell responses and antibodies elicited by vaccination with simian immunodeficiency virus Nef do not confer protection against virus challenge.

The efficacy of immunizing with a combination of simian immunodeficiency virus (SIV) Nef vaccines was evaluated. Four vaccinates received three intradermal immunizations with recombinant vaccinia virus that expressed SIV Nef, followed by three intramuscular immunizations with rDNA also expressing SIV Nef. Finally, the four vaccinates received two subcutaneous boosts with recombinant SIV Nef protein. This immunization protocol elicited anti-Nef antibodies in all of the vaccinates as well as specific proliferative responses. However, specific cytotoxic T cell responses were not detected before virus challenge. All vaccinates were challenged intravenously with 10 MID(50) of SIVmacJ5 along with four controls. All eight subjects became infected after SIV challenge and there were no group-specific differences in virus load as measured by virus titration and vRNA analysis. The results of this study support indirectly the report from Gallimore and colleagues (Nat Med 1995;1:1667) suggesting that CD8(+) T lymphocyte responses are required for Nef-based vaccines to restrict SIV infection. If Nef-based vaccines are to be beneficial in controlling infection with immunodeficiency viruses, then it will be necessary to develop more effective immunization protocols that elicit potent CD8(+) cell responses reproducibly.

Animals↗

Computerized strain-gauge plethysmography - An alternative method for the detection of lower limb deep venous thrombosis?

AIM: To test the ability of computerized strain-gauge plethysmography to act as a screening test for lower limb deep venous thrombosis (DVT). MATERIALS AND METHODS: Over an 8-month period, all patients referred to our Medical Assessment Unit with suspected lower limb DVT were considered for inclusion in the study. Each patient underwent both plethysmography and ascending venography within 24 h, and the presence or absence of thrombus in the popliteal, superficial femoral or iliac veins was noted. The results of the two tests were then used to determine the accuracy of computerized strain-gauge plethysmography in detecting above knee DVT. RESULTS: The screening tests and venograms of 239 patients referred with clinically suspected lower limb DVT were compared. The false negative rate of plethysmography was 15.4%, which is significantly different from the 4.8% claimed by the manufacturers of this device (P = 0.00003). CONCLUSIONS: In a population of acute admissions with suspected lower limb DVT, computerized strain-gauge plethysmography is not suitable for use as a screening test due to an unacceptably high proportion of false negative screens.

Diagnosis, Computer-Assisted↗

Wrong ideas.

Explore the source record for details and available documents.

Acquired Immunodeficiency Syndrome↗

The use of ion exchange to remove aluminum from water used in hemodialysis.

Since the established techniques for removing aluminum from the water used in dialysis (reverse osmosis and deionization) are relatively complex and expensive, it was decided to investigate a number of simple ion-exchange techniques. In 48 of 217 tap water samples obtained from 61 home hemodialysis patients in southeast Scotland, the aluminum content exceeded 2 mumol/L (54 micrograms/L)--a level that has been associated with dialysis dementia and fracturing osteodystrophy. Dialysate prepared from this water after softening had approximately half this aluminum content, but in 17 instances the concentration still exceeded 2 mumol/L. In vitro studies showed that the anion-exchange resin IRA 400 (Rohm-Haas, Philadelphia) in the chloride phase was very effective at removing aluminum. A commercial water softener was modified by the addition of this resin, and installed in the home dialysis training unit at the Princess Alexandra Hospital in Brisbane. Over a 12-month period in which the tap water aluminum content averaged over 10 mumol/L (270 micrograms/L), the product water had an aluminum content consistently under 2 mumol/L, being under 1 mumol/L (27 micrograms/L) on 19 out of 20 occasions. The modified softener was regenerated with a saturated sodium chloride solution at 2-week intervals, using the manufacturer's protocol for the unmodified softener. Provided that dialysate and plasma aluminum levels are monitored on a regular basis, it is felt that this simple technique of aluminum removal may be appropriate for many home hemodialysis situations.

Aluminum↗