PubMed Health⌕ Search

Biomedical subjects

J Cristóvão

Publications and source records attributed to J Cristóvão.

6 recordsLinked to original sources

Biventricular pacing--early experience.

INTRODUCTION: Biventricular pacing has been studied for the treatment of chronic heart failure (CHF). This technique seems to be able to improve symptoms and exercise tolerance, in patients with advanced CHF and prolonged QRS duration. OBJECTIVE: To present our experience with biventricular pacing in the management of severe CHF. METHODS: Between June 2000 and March 2001, 8 patients with dilated cardiomyopathy and left bundle branch block (LBBB) were selected for transvenous biventricular pacing system implantation. Mean age: 54.12 +/- 16.8 years; 5 males. The etiology was: idiopathic in 6 cases; operated congenital heart disease in 1, and ischemic in the other. Despite tailored treatment of CHF (with all patients taking diuretics and angiotensin-converting enzyme inhibitors), 7 patients remained in NYHA class III and 1 in IV. The quality of life score (assessed by the "Minnesota living with heart failure questionnaire") was 62.25 +/- 11.29. Seven patients had sinus rhythm and only one chronic atrial fibrillation; mean PQ duration--220 +/- 76.37 ms; mean QRS duration--168.75 +/- 20.31 ms. RESULTS: Implant failure, due to coronary sinus dissection and to excessive fluoroscopy time, with no coronary sinus catheterization, occurred in 2 cases (success rate: 75%). Implant data: mean implant procedure duration: 122.5 +/- 47.82 min; mean fluoroscopy time: 35.66 +/- 22.06 min; QRS duration, after implant: 133.33 +/- 15.05 ms. Left ventricular lead final position: anterolateral in 2 patients and lateral in 4. Pacing thresholds: biventricular--1.36 +/- 0.6 V; right ventricle--0.28 +/- 0.04 V; right atrium--0.32 +/- 0.08 V. Pacing impedance (left ventricle): 1013.33 +/- 147.87 omega. Follow-up (1st and 3rd month): one patient died, suddenly, 15 days after the procedure. In the others, an improvement in the quality of life index and functional class was found. These results were independent of echocardiography data. There were no significant differences in the pacing threshold and impedance during the follow-up. CONCLUSIONS: Patients with advanced CHF and widened QRS benefited from biventricular stimulation, in which improvement on the clinical status was evident.

Adolescent↗

Repolarization abnormalities after catheter ablation of differently located overt accessory pathways.

PURPOSE: Electrical repolarization abnormalities are usually seen after radiofrequency catheter ablation in overt accessory atrio-ventricular pathways. These abnormalities have been recognised as "cardiac memory". The aim of this study was to assess the relationships between electrical repolarization abnormalities and the location of the accessory atrioventricular pathway in the atrio-ventricular junction. We also assessed the relationship between electrical repolarization abnormalities and the degree of ventricular preexcitation. MATERIAL AND METHODS: Our group consisted of 45 patients with overt and persistent preexcitation who were successfully submitted to radiofrequency catheter ablation. Mean age was 38.9 +/- 14.9 years (14 to 64), 28 of whom (62.2%) were male and 17 (37.8%) female. The location of accessory pathways the was left lateral in 14 patients, right posteroseptal in 14 patients, right mesoseptal in eight patients, right anteroseptal in four patients and other locations in the remaining four. Surface electrocardiograms were performed immediately following ablation, 24 hours later and three or more months after the procedure. RESULTS: T wave abnormalities (flattened, inverted or peaked) were detected on the first day in 51% of patients, being more frequent after right accessory pathway ablation (86.9% versus 13.1% in left accessory pathways). These electrocardiographic changes were particularly frequent in patients with right mesoseptal (5/8, 62.5%) and posteroseptal (13/14, 93.3%) pathways, of which 62.5% and 71.5%, respectively, showed marked preexcitation before ablation. These findings were significantly different from those observed in patients with left lateral pathways--only 35.7% showed marked preexcitation and only two of fourteen patients (14.3%) presented T wave abnormalities after ablation. After the third month, most of the patients that had undergone successful ablation presented completed electrocardiographic normalization. CONCLUSIONS: Patients undergoing radiofrequency catheter ablation for right accessory pathways show more frequently repolarization abnormalities than those submitted to ablation of the left lateral accessory pathways. The occurrence of these changes after preexcitation resolution may depend on the degree of previous preexcitation.

Adolescent↗

Permanent pacing in patients with congenital atrio-ventricular block--experience of 33 cases.

OBJECTIVES: The authors review permanent pacing in patients with congenital atrioventricular block (CAVB) and present their experience in permanent pacing in this pathology. STUDY POPULATION AND METHODS: In a population of 4,355 patients submitted to implantation of permanent pacing between January 1980 and January 1998, 33 (0.75%) had CAVB. The mean age of the patient population with CAVB was 16.7 years (aged from eleven days to 35 years); 33% were below 10 years of age; 16 patients were male. The majority of the patients had symptoms of brain hypoperfusion; two patients had concomitant malignant ventricular tachyarrythmias (one of these with Torsade de Pointes due to congenital long QT syndrome). Transvenous (endocardial) pacing was used in 32 patients (two with previous epicardial pacing and exit block) and epicardial pacing in one. The mode of stimulation used was VVI in three patients, DDD in eight patients, VVIR in 14 patients, DDDR in four patients and VDD in four. Smaller pulse generators were used in children of lower weight. In recent years single lead VDD systems have been preferred whenever technically possible. Vascular access was the left cephalic vein in 17 patients; the left subclavian vein in 14 patients and the right jugular vein in one patient. During a mean follow-up of 6.9 years, two patients with ventricular stimulation systems developed "Pacemaker Syndrome" and required a change of mode of stimulation. Lead fracture and posterior cutaneous necroses were observed in two other patients, who were accordingly submitted to surgical revision. It was deemed necessary, one year later, to increase the lead loop in a child with a permanent pacemaker implanted at eleven days of age. No other complications occurred with the other patients; replacement of the pulse generators was performed in an elective manner. CONCLUSIONS: CAVB is a rare indication for the implantation of a permanent pacemaker. In children, in the majority of cases, endocardial stimulation is possible in spite of the obvious technical difficulties due to low weight. Sequential, more physiological, stimulation systems should be preferred. However, VVIR stimulation systems of smaller dimensions can be the first choice of mode of stimulation in smaller children, mainly due to anatomical and technical limitations.

Adolescent↗

[Effect of programming different AV intervals on mitral insufficiency in patients with DDD pacemaker].

OBJECTIVE: To study the effect of programming three different atrioventricular intervals (AVI) on mitral insufficiency (MI) in patients with permanent pacemaker due to complete atrioventricular block. METHODS: We included 9 patients (mean age 62 +/- 11 years; 6 men), with permanent DDD pacemaker, isolated MI and normal ventricular function. We evaluated MI (in a quantitative way) and cardiac output (CO) through echocardiographic examination with three different AVI (100, 150 and 200 ms). RESULTS: We observed a reduction in the severity of MI with the reduction of the AVI (best results obtained with AVI of 100 ms). We also observed an increase in the CO in 4 patients (those with MI of greater degree) with AVI of 100 ms. CONCLUSIONS: We observed a correlation of longer AVI with greater degree of MI; our results point to the possibility of increasing the CO of patients with greater degrees of MI with shortening of the AVI (probably due to a partial recovery of the regurgitant volume).

Aged↗

[Non-invasive evaluation of left ventricular function (systolic time interval) in patients using double-chamber pacemakers programmed on DDD and VVI].

OBJECTIVE: To evaluate changes on left ventricular function as assessed by systolic time intervals (STI), by programming "physiological" pacemakers either on VVI or DDD mode. STUDY DESIGN: Comparison of STI values--electromechanical systole (QS2); left ventricular ejection time (LVET); pre-ejection period (PEP); PEP/LVET--in patients submitted to double chamber pacing programmed in DDD or VVI mode. SETTING: Cardiac Pacing Center in a Department of Cardiology at a University Hospital. PATIENTS: We have studied 12 patients (3 men, 9 women), mean age 56.16 years (range 25-76 years) treated with double chamber pacing. INTERVENTIONS: Initial measurements of STI in DDD or one week in VVI mode, and again after one week in DDD mode. RESULTS: Significant changes were found after the first week in VVI pacing, versus baseline determination in DDD pacing, for LVET, PEP, and PEP/LVET (p less than 0.05). At the end of the second week (DDD pacing), there were also statistically significant differences for QS2 (P less than 0.05), LVET (P less than 0.01) and PEP/LVET (P less than 0.05) values when compared with the ones obtained in VVI pacing, at the end of the preceding week. No significant changes were found between the initial and the final STI determinations (both in DDD pacing). CONCLUSION: We concluded for a better performance of the left ventricle at rest when "physiological" pacing is compared with VVI pacing.

Adult↗