PubMed Health⌕ Search

Biomedical subjects

J Crommen

Publications and source records attributed to J Crommen.

At least 19 recordsLinked to original sources

Robustness testing of a chiral NACE method for R-timolol determination in S-timolol maleate and uncertainty assessment from quantitative data.

A robustness test of a capillary electrophoresis method for the chiral separation of timolol in nonaqueous acidified media was performed. A two-level Plackett-Burman design was applied in which one qualitative and six quantitative factors were examined. Resolution, migration times and relative migration times to pyridoxine (selected as internal standard) were examined as qualitative responses to evaluate electrophoretic performance. A quantitative response, the content of R-timolol in S-timolol maleate sample, was also considered. Even though some significant factor effects were observed on the qualitative responses, it was still possible to quantify the R-timolol in the S-timolol maleate samples properly. The quantitative response was not significantly affected by the selected factors, demonstrating the robustness of the procedure. However, the use of different HDMS-beta-CD batches seemed to affect both types of responses necessitating to introduce a warning in the procedure. Since the experiments of the Plackett-Burman design can be assimilated to laboratories in an interlaboratory study, uncertainty can be evaluated using the robustness test data. The robustness test was set-up in such a way that the required variances could be estimated.

Adrenergic beta-Antagonists↗

Performances of a multidimensional on-line SPE-LC-ECD method for the determination of three major catecholamines in native human urine: validation, risk and uncertainty assessments.

A novel, multidimensional on-line SPE-LC method with electrochemical detection is described for the fully automated and direct analysis of the catecholamines norepinephrine, epinephrine and dopamine in urine. The integrated extractive clean-up of the raw biofluid is based on a SPE-column packed with restricted access material (RAM) which is modified with the affinity ligand nitrophenylboronic acid. The method was fully validated according to a recent approach based on an accuracy profile. The acceptance limits were set at +/-15% of the nominal concentration values. The method was found accurate over a concentration range from 15 to 500 microg/l for norepinephrine, from 5 to 500 microg/l for epinephrine and from 50 to 500 microg/l for dopamine. The relative risk for the use of the validated method in routine analysis was also assessed based on this validation strategy. It was found that at most 3.5% of future sample measurements will fall outside the acceptance limits. This demonstrates the high reliability of the analytical method described. Moreover, the measurements uncertainties were deduced from the validation experiments without any additional effort.

Catecholamines↗

The transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid in Lidoses: use of total error as decision criterion.

Two new statistical approaches to assess the validity of the transfer of a LC-UV method for the determination of fenofibrate and fenofibric acid were investigated and compared to the conventional approaches generally used in this domain. These new approaches, namely the Tolerance Interval and the Risk approaches, are based on the simultaneous evaluation of the systematic (or trueness) and random (or precision) errors of the transfer into a single criterion called total error (or accuracy). The results of the transfer showed that only the total error based approaches fulfilled the objective of an analytical method transfer, i.e. to give guarantees that each future measurement made by the receiving laboratory will be close enough to the true value of the analyte in the sample. Furthermore the Risk approach was the most powerful one and allowed the estimation of the risk to have future measurements out of specification in the receiving laboratory, therefore being a risk management tool.

Chromatography, Liquid↗

[Comparison of three approaches for uncertainty estimation].

Three different approaches for the estimation of uncertainty measurements using the same analytical method were compared, namely validation, robustness and inter-laboratory studies. The uncertainty obtained with the robustness study! predicted well the uncertainty of the inter-laboratory study. On the other hand, the uncertainty estimation obtained with the validation study is lower than those obtained with the two other approaches but is still acceptable as long as the analytical method will be used in a single laboratory.

Chromatography, Liquid↗

Automated method for the determination of a new matrix metalloproteinase inhibitor in ovine plasma and serum by coupling of restricted access material for on-line sample clean-up to liquid chromatography.

A fully automated liquid chromatographic method was developed for the determination of Ro 28-2653, a new synthetic inhibitor of matrix metalloproteinases (MMPs), in ovine serum and plasma. The method was based on the coupling of a pre-column packed with restricted access material, namely LiChrospher RP-8 ADS (alkyl diol silica), for sample clean-up to an analytical column containing octyl silica stationary phase. One hundred microl of biological sample, to which 2-propanol was automatically added, were injected onto the ADS pre-column, which was then washed with a washing liquid consisting of a mixture of 25 mM phosphate buffer (pH 7.0) and acetonitrile (90:10; v/v) for 10 min. By rotation of the switching valve, the analyte was then eluted in the back-flush mode with the LC mobile phase composed of a mixture of acetonitrile and 25 mM phosphate buffer (pH 7.0) (57:43; v/v). The UV detection was performed at 395 nm. The main parameters likely to influence the sample preparation technique were investigated. The method was then validated over a concentration range from 17.5 to 1950 ng/ml, the first concentration level corresponding to the lower limit of quantitation. At this concentration level, the mean bias and the R.S.D. value for intermediate precision were -2.4% and 4.2%, respectively.

Animals↗

Integrated on-line sample clean-up using cation exchange restricted access sorbent for the LC determination of atropine in human plasma coupled to UV detection.

A new, simple and fully automated liquid chromatographic (LC) method with UV detection has been developed for the direct determination of atropine in plasma. Sample clean-up was based on the use of cation exchange restricted access material (RAM) in a pre-column, coupled to LC by means of a column switching system. After direct injection of a 200 microl-volume of plasma sample, the biological matrix was washed out for 10 min using a washing liquid composed of 2 mM lithium perchlorate adjusted to pH 3.0 and methanol (97:3; v/v). By rotation of the switching valve, atropine was then eluted in the back-flush mode for 2 min and transferred to the analytical column packed with octadecyl silica by the LC mobile phase constituted of a mixture of acetonitrile and potassium phosphate buffer (pH 3.0; 50 mM) containing 2 mM sodium heptanesulfonate (16:84; v/v). The UV detection was performed at 220 nm. The method was validated according to a new approach based on accuracy profile over a concentration range from 25 ng/ml, corresponding to the limit of quantitation, to 1000 ng/ml. The method was then applied for the determination of atropine in plasma after intravenous administration to hospitalised patients.

Atropine↗

Development and validation of a fully automated LC method for the determination of cloxacillin in human plasma using anion exchange restricted access material for sample clean-up.

In the framework of a preliminary investigation on the plasma profile of cloxacillin after oral administration, a simple and rapid LC method was developed for the direct determination of this compound in human plasma. The on-line sample clean-up was carried out using a weak anion exchanger (diethylaminoethyl groups) as restricted access material (RAM). The effects of the washing liquid pH, the ionic strength and the addition of organic modifier to the washing liquid were studied in order to obtain an efficient sample clean-up and a high recovery of cloxacillin. The separation was achieved on octadecylsilica stationary phase using a mobile phase consisting in a mixture of phosphate buffer (pH 4.0; 25 mM) and acetonitrile (72:28, v/v). The UV detection was performed at 215 nm. The most appropriate regression model of the response function as well as the limit of quantitation (LOQ) were first selected during the pre-validation step. These criteria were then assessed during the formal validation step. The LOQ was 50 ng/ml. The method was also validated with respect to analyte recovery, precision, trueness, accuracy and linearity. Finally, it was successfully applied for the analysis of the first plasma samples obtained from patients having taken an oral dose of 500 mg cloxacillin.

Anion Exchange Resins↗

[Low dose intravitreal triamcinolone acetonide in the treatment of neovasular glaucoma].

PURPOSE: To report the effect of an intravitreal injection of 4 mg of crystalline triamcinolone acetonide (Kenacort) as symptomatic treatment of neovascular glaucoma. MATERIAL AND METHODS: This clinical study is based on clinical and experimental investigations that examined the tolerability and the angiostatic effect of triamcinolone acetonide. The study includes prospectively 8 eyes of 8 patients with neovascular glaucoma secondary to ischemic central retinal vein occlusion (n=8). All patients received an intravitreal injection of 4 mg of crystalline triamcinolone acetonide (0.1 cc) as the only procedure or in combination with transscleral cyclodiode as glaucoma treatment. Their mean age was 74.5 +/- 14.4 years. Mean intraocular pressure (IOP) was 38.9 +/- 9.3 mmHg. Mean follow-up was 6 months. RESULTS: 4 of 8 patients were treated by crystalline triamcinolone acetonide as the only procedure (n=3). Twenty seven days after intravitreal kenacort injection, the others four patients have been treated by transscleral cyclodiode (n=4) as glaucoma treatment. After injection, including the first postoperative day, patients report a subjective reduction of ocular pain. Furthermore no intra- or extraocular inflammatory reactions were observed during the follow-up. Intraocular pressure was significantly reduced to 18 +/- 6.2 mm Hg at the end of the follow-up period. When considering only the four patients in which the intraocular cortisone injection was the only procedure performed, mean intraocular pressure decreased from 41.75 +/- 7.05 mm Hg to 20.5 +/- 6.6 mm Hg. Iris neovascularisation was significantly decreased from grade IV to grade I in all patients at the end of the follow-up CONCLUSION: Intravitreal injection of 4 mg triamcinolone acetonide contributes to a better management of the neovascular glaucoma.

Aged↗

Fully automated method for the liquid chromatographic-tandem mass spectrometric determination of cyproterone acetate in human plasma using restricted access material for on-line sample clean-up.

A new automated method for the quantitative analysis of cyproterone acetate (CPA) in human plasma has been developed using on-line solid phase extraction (SPE) prior to the LC-MS/MS determination. The method was based on the use of a pre-column packed with internal-surface reversed-phase material (LiChrospher RP-4 ADS, 25 mm x 2 mm) for sample clean-up coupled to LC separation on an octadecyl silica stationary phase by means of a column switching system. A 30 microl plasma sample volume was injected directly onto the pre-column using a mixture of water, acetonitrile and formic acid (90:10:0.1 (v/v/v)) adjusted to pH 4.0 with diluted ammonia as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase consisting of water, methanol and formic acid (10:90:0.1 (v/v/v)). The dispensing flow rates of the washing liquid and the LC mobile phase were 300 microl min(-1). Medroxyprogesterone acetate (MPA) was used as internal standard. The MS ionization of the analytes was achieved using electrospray (ESI) in the positive ion mode. The pseudomolecular ionic species of CPA and MPA (417.4 and 387.5) were selected to generate daughter ions at 357.4 and 327.5, respectively. Finally, the developed method was validated according to a new approach using accuracy profiles as a decision tool. Very good results with respect to accuracy, detectability, repeatability, intermediate precision and selectivity were obtained. The LOQ of cyproterone acetate was 300 pg ml(-1).

Automation↗

Evaluation of a novel anion-exchange restricted-access sorbent for on-line sample clean-up prior to the determination of acidic compounds in plasma by liquid chromatography.

A new kind of silica-based restricted-access material (RAM) with anionic properties has been tested in pre-columns for on-line solid-phase extraction of acidic compounds from directly injected plasma samples prior to their determination by reversed-phase liquid chromatography (LC), using the column-switching technique. The outer surface of the porous RAM particles contains hydrophilic diol groups while diethylaminoethyl (DEAE) groups are bound to the internal surface which gives the sorbent the properties of a weak anion exchanger towards low-molecular-mass compounds. Due to an appropriate pore diameter (about 6 nm), macromolecules, such as proteins, are physically excluded from the pores and flushed directly out during the sample clean-up process, while small compounds have access to the inner surface and can be retained mainly by electrostatic interactions. The retention capability of this novel packing material has been tested for some hydrophilic acidic compounds such as aspartic acid, glutamic acid, ascorbic acid and acetylcysteine as well as for some more hydrophobic drugs such as naproxen, ibuprofen and diclofenac, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The efficiency of the sorbent to clean-up complex matrices was also tested using human plasma and urine samples. A generic washing liquid composition was then selected in order to obtain efficient and selective sample clean-up as well as a high recovery of the acidic analytes.

Acids↗

Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

Androgen Antagonists↗

Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

Anti-Bacterial Agents↗

An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progress and limitations.

The Société Française des Sciences et Techniques Pharmaceutiques (SFSTP) published in 1997 a guide on the validation of chromatographic bio-analytical methods, which introduces new concepts in three different areas: stages of the validation, test of acceptability of a method and design of experiments to perform. In 'stages of validation', the SFSTP guide requires two phases to validate a method. The first phase, called 'prevalidation', is intended to (1) identify the model to use for the calibration curve; (2) evaluate the limits of quantitation; and (3) provide good estimates of the precision and bias of the method before designing the 'validation' phase per se. In the 'test of acceptability', the use of the interval hypotheses is envisaged by the SFSTP guide, not on the parameters of bias and precision, but on individual results by mixing mean bias and intermediate precision in a single test. The SFSTP guide also avoids the use of Satterthwaite's df for testing the acceptability. The reasons for those choices are discussed extensively. In 'design of experiments', much effort has been devoted to improving the quality of results by optimally designing and sizing the experiments to perform in validation. The rationale for using near D-optimal designs for the calibration curve is demonstrated and sample sizes are proposed to correctly size the validation experiments.

Chromatography↗

Fully automated LC method for the determination of sotalol in human plasma using restricted access material with cation exchange properties for sample clean-up.

A simple and rapid fully automated bio-analytical method for the liquid chromatographic (LC) determination of sotalol in human plasma has been described. The method is based on the use of a new kind of porous silica restricted access material (RAM) with cation exchange properties for sample clean-up. 100 microl of plasma samples were directly injected into the precolumn coupled on-line to a reversed-phase column (RP-Select B) by means of column switching system. The plasma matrix was washed out for 10 min using a washing liquid composed of 2 mM lithium perchlorate and methanol (97:3; v/v). By rotation of the switching valve, the analytes were then eluted in back-flush mode for 2 min and transferred to the analytical column by the LC mobile phase constituted of a mixture of methanol and 50 mM potassium phosphate buffer (pH 7.0) containing 1 mM 1-octanesulphonic acid sodium salt (20:80; v/v). The flow-rate was 1.0 ml/min and sotalol was detected using fluorescence detection at 235 and 300 nm as excitation and emission wavelengths, respectively. The method was then validated using a new approach based on accuracy profile over a concentration range from 5 to 500 ng/ml. The limit of quantitation (LOQ) was 5 ng/ml and the total analysis time was 19 min.

Cation Exchange Resins↗

Enantiomer separation of N-protected amino acids by non-aqueous capillary electrophoresis and high-performance liquid chromatography with tert.-butyl carbamoylated quinine in either the background electrolyte or the stationary phase.

A non-aqueous CE method was developed for evaluating the chiral discrimination potential of cinchona alkaloids and different kinds of carbamoylated derivatives of quinine and quinidine type chiral selectors towards acidic analytes, in particular a series of various Bz (benzoyl), DNB (3,5-dinitrobenzoyl) and DNZ (3,5-dinitrobenzyloxycarbonyl) amino acid derivatives. In this study, the enantioselectivity values obtained in non-aqueous CE with tert.-butyl carbamoylated quinine as chiral additive have been compared with the values found for the same series of selectands in HPLC using the same selector immobilized onto silica as chiral stationary phase. Similarly to the background electrolyte used in CE an ethanol-methanol mixture (60:40, v/v) containing 100 mM octanoic acid and 12.5 mM ammonia has been selected as HPLC mobile phase. Under these conditions, a good correlation (r = 0.954) between the enantioselectivities observed with the two techniques has been obtained. Thus the non-aqueous CE method can be applied as a screening tool for the rapid evaluation of the chiral discrimination potential of a large set of newly developed chiral selectors derived from quinine and related alkaloids.

Amino Acids↗

Oral bioavailability in sheep of albendazole from a suspension and from a solution containing hydroxypropyl-beta-cyclodextrin.

Albendazole (ABZ) is a benzimidazole derivative with a broad spectrum of activity against human and animal helminthe parasites. ABZ has a very poor aqueous solubility. This study shows that hydroxypropyl-beta-cyclodextrin (HP-beta-CD) is able to form inclusion complexes with ABZ and that is able to increase its aqueous solubility. A synergistic effect exists between HP-beta-CD and citric acid. The combination of HP-beta-CD (200 mM) and citric acid (50 mM) allows dissolution of more than 1.5 mg of ABZ per ml. The aim of this study is the in vivo evaluation in sheep of a solution of the inclusion complex of ABZ with HP-beta-CD in comparison with a suspension of the same drug. A significant (P<0.05) increase in the relative bioavailability is obtained with the solution containing the ABZ-HP-beta-CD complex as measured by ABZSO plasma levels. The area under the curve (AUC(0--> proportional, variant )) of the solution is 37% higher than that obtained with the suspension. Likewise the peak plasma concentration (C(max)) is twice that of the solution while the time to reach C(max) (T(max)) is reduced.

2-Hydroxypropyl-beta-cyclodextrin↗

Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography.

A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.

Automation↗

Separation, identification and quantitation of ceramides in human cancer cells by liquid chromatography-electrospray ionization tandem mass spectrometry.

Ceramides are important intracellular second messengers that play a role in the regulation of cell growth, differentiation and programmed cell death. Qualitative and quantitative analysis of these second messengers requires sensitive and specific analytical methods to detect endogenous levels of individual ceramide species and to differentiate between them. Nine synthetic ceramides were separated by liquid chromatography coupled to tandem mass spectrometry on a C18 bonded silica column. The lipids were eluted in gradient elution mode using a mixture of water, acetonitrile and 2-propanol as mobile phase. They were detected by reaction monitoring performed on positive ion electrospray generated ions. Collision-induced fragmentations conducted on ceramides produced a well characteristic product ion at m/z 264, making multiple reaction monitoring (MRM) well suited for various ceramides quantitative measurements. After optimization of the extraction step, the proposed methodology was able to identify and quantify different ceramide species issued from human cancer cells. The method could be validated for C16, C18 and C20 ceramides, quantified at the nanogram level. The validation exhibits good results with respect to linearity, accuracy and precision.

Ceramides↗