Enantioseparation of aminoglutethimide with cyclodextrins in capillary electrophoresis and studies of selector-selectand interactions using NMR spectroscopy and electrospray ionization mass spectrometry.

The enantiomers of aminoglutethimide [2-(p-aminophenyl)-2-ethylglutarimide, AGT] can be resolved in CE using all of three most commonly used native cyclodextrins (CD): alpha-, beta-, and gamma-CDs. The migration order of the enantiomers was opposite using beta-CD compared to alpha- and gamma-CDs as chiral selectors. In order to examine some underlying mechanisms of the chiral recognition the interaction of AGT with the chiral selectors was studied with one- and two-dimensional NMR spectroscopy and electrospray ionization mass spectrometry (ESI-MS). The Job's and Scott's plots constructed based on the complexation-induced chemical shifts (CICS) observed in NMR spectra provided some preliminary information on the stoichiometry of the intermolecular complexes but did not seem to be absolutely reliable perhaps because the self-association of the analyte molecules and the formation of multiple type selectand-selector complexes. Therefore, an attempt was made to characterize the complexes using ESI-MS. This technique provided information on the stoichiometry and relative affinity constants of selector-selectand complexes. The information on the structure of complexes in the solution was obtained using one-dimensional rotating frame nuclear Overhauser enhancement (1D-ROESY) NMR spectroscopic studies. Significant differences were observed between the structures of the AGT complexes with beta- and gamma-CD.

Aminoglutethimide↗

Elimination of adsorption effects in the analysis of water-soluble vitamins in pharmaceutical formulations by capillary electrophoresis.

A tendency to an increase in migration times was observed when different water-soluble vitamins were analysed repeatedly in pharmaceutical preparations by capillary electrophoresis. In order to better understand the origin of this effect, the influence of the vitamins and the excipients, such as cellulose derivatives, was investigated. These studies indicated that the increase in analyte migration times was most probably due to the adsorption of different kinds of constituents to the capillary wall. Different rinsing procedures were tested in order to eliminate these unfavourable effects. A rinse of the capillary with a 25 mM sodium dodecyl sulfate (SDS) solution in the running buffer between successive runs was found to be particularly effective when the analysis was performed by free solution capillary zone electrophoresis (CZE). When the vitamins were determined by micellar electrokinetic chromatography (MEKC) using SDS as surfactant, a short capillary rinse with the running buffer was sufficient to obtain reproducible migration times. The CZE and MEKC methods developed were validated and compared. Both methods could be applied to the determination of water-soluble vitamins in different multivitamin formulations.

Chemistry, Pharmaceutical↗

Enantiomeric separation of N-protected amino acids by non-aqueous capillary electrophoresis using quinine or tert-butyl carbamoylated quinine as chiral additive.

A capillary electrophoretic (CE) method for the enantioseparation of N-protected chiral amino acids was developed using quinine and tert-butyl carbamoylated quinine as chiral selectors added to nonaqueous electrolyte solutions (NACE). A series of various N-derivatized amino acids were tested as chiral selectands, and in order to optimize the CE enantioseparation of these compounds, different parameters were investigated: the nature of the organic solvent, the combination of different solvents, the nature and the concentration of the background electrolyte, the selector concentration, the capillary temperature, and the applied voltage. The influence of these factors on the separation of the analyte enantiomers and the electroosmotic flow was studied. Generally, with tert-butyl carbamoylated quinine as chiral selector, better enantioseparations were achieved than with unmodified quinine. Optimum experimental conditions were found with a buffer made of 12. 5 mM ammonia, 100 mM octanoic acid, and 10 mM tert-butyl carbamoylated quinine in an ethanol-methanol mixture (60:40 v/v). Under these conditions, DNB-Leu enantiomers could be separated with a selectivity factor (alpha) of 1.572 and a resolution (Rs) of 64.3; a plate number (N) of 127,000 and an asymmetry factor (As) of 0.93 were obtained for the first migrating enantiomer.

Amino Acids↗

Separation of nonsteroidal anti-inflammatory drugs by capillary electrophoresis using nonaqueous electrolytes.

The aim of the present work was to investigate the separation of nonsteroidal anti-inflammatory drugs (NSAIDs: niflumic acid, flufenamic acid, piroxicam, alclofenac, tiaprofenic acid, flurbiprofen, suprofen, ketoprofen, naproxen, indomethacin, carprofen, indoprofen, sulindac) in capillary electrophoresis (CE) using completely nonaqueous systems. The influence of different parameters such as nature and proportion of organic solvent (methanol, acetonitrile, 2-propanol), apparent pH (ranging from 7 to 9) and temperature (ranging from 25 to 40 degrees C) on selectivity and migration times were studied systematically in an uncoated fused-silica capillary. A nonaqueous electrolyte made of 50 mM ammonium acetate - 13.75 mM ammonia in methanol proved to resolve 11 NSAIDs at 25 degrees C and 13 NSAIDs at 36 degrees C, both within 13 min and without a modifier besides the methanol itself. The same buffer containing 30% acetonitrile provides a satisfactory separation for 13 NSAIDs within 14 min at 25 degrees C.

Anti-Inflammatory Agents, Non-Steroidal↗

Designed combination of chiral selectors for adjustment of enantioseparation selectivity in capillary electrophoresis.

In this study an attempt has been made to explain the reasons for changing the enantioseparation selectivity in some dual cyclodextrin (CD) systems compared to the use of single chiral selectors in capillary electrophoresis (CE). An explanation for selectivity changes is proposed based on the effect of the chiral selector on the mobility of the analyte. In order to support the proposed mechanism, several dual systems were designed on the basis of the known recognition pattern of enantiomers for individual CDs. In most cases the separation selectivity could be adjusted in a designed way. There was no experimental evidence for simultaneous binding of a given chiral analyte with both chiral selectors or of chiral recognition of an analyte complex with one CD by another CD.

Electrophoresis, Capillary↗

Automated sample preparation techniques for the determination of drug enantiomers in biological fluids using liquid chromatography with chiral stationary phases.

The determination of drug enantiomers has become of prime importance in the field of pharmaceutical and biomedical analysis. Liquid chromatography (LC) is one of the most frequently used techniques for achieving the separation and quantitation of the enantiomers of drug compounds. In the bioanalytical field, the integrated systems present an interesting alternative to time-consuming sample preparation techniques such as liquid-liquid extraction. Solid phase extraction (SPE) on disposable cartridges, dialysis or column switching are sample preparation techniques that can be fully automated and applied to enantioselective analysis in biological fluids. The selection of the most appropriate LC mode and chiral stationary phase for enantioseparations in bioanalysis is discussed and some aspects of these automated sample preparation procedures are compared, such as selectivity, detectability, elution of the analytes from the extraction sorbent, sample volume and analyte stability.

Buffers↗

Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column.

A fully automated liquid chromatographic (LC) method for the simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma has been developed. The method is based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher ADS) for sample clean-up coupled to LC analysis on a cellulose tris(4-methylbenzoate) based chiral stationary phase (Chiralcel OJ-R). A 100-microliter plasma sample was injected directly on the precolumn packed with LiChrospher RP-18 ADS using a mixture of pH 5.0 phosphate buffer-methanol (97:3, v/v) as washing liquid. The analytes were then eluted in the back-flush mode with the LC mobile phase. The enantiomeric separation of methylphenobarbital was achieved on Chiralcel OJ-R). The retention times were modelled using a D-optimal design with ten experimental points in order to optimise the LC mobile phase for the separation of phenobarbital from the enantiomers of mephobarbital. The factors selected were the acetonitrile content, the pH and the sodium perchlorate concentration in the mobile phase. A Derringer's desirability function was used to find an optimal and robust solution within the experimental domain. The mobile phase selected consisted of a mixture of pH 7.0 phosphate buffer-acetonitrile (60:40, v/v). The elution profiles of phenobarbital, methylphenobarbital and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were then determined. Finally, the method developed was validated.

Chromatography, Liquid↗

Simultaneous determination of pirlindole enantiomers and dehydropirlindole by chiral liquid chromatography.

Liquid chromatography was employed for the determination of pirlindole enantiomers and its oxidation product dehydropirlindole (DHP). The direct separation of pirlindole enantiomers and DHP was achieved on a cellulose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase (Chiralcel OD-R). Acetonitrile was used as the organic modifier and sodium perchlorate was used as an ionic additive in the mobile phase. The influence of acetonitrile and sodium perchlorate concentrations on enantioselectivity and achiral selectivity towards DHP was investigated in order to find suitable conditions for the determination of low amounts of each analyte. The mobile phase selected consisted of a mixture of acetonitrile and phosphate buffer (pH 5.0) containing sodium perchlorate (0.05 M) (35:65, v/v) and the UV detector was set at 220 nm. The method developed was validated and was found to be linear in the 0.1-5 microg ml(-1) range (r2 = 0.999 for the three compounds). Repeatability and the intermediate precision for the three analytes at a concentration of 0.1 microg ml(-1) were about 3 and 4%, respectively. This concentration corresponds to the quantification of 0.1% for the minor enantiomer. Actual determinations of enantiomeric purity for single enantiomers of pirlindole were performed.

Acetonitriles↗

Method development strategies for the enantioseparation of drugs by capillary electrophoresis using cyclodextrins as chiral additives.

General strategies for the development of capillary electrophoretic methods for the enantiomeric separation of basic, acidic or neutral drugs were developed. For all kinds of compounds, the use of a buffer made of 100 mM phosphoric acid adjusted to pH 3 with triethanolamine and containing anionic and/or uncharged cyclodextrin (CD) derivatives as chiral selectors was recommended. Two different optimization schemes depending on the acidic or basic character of the analytes, were elaborated. For most basic compounds present in cationic form at pH 3, enantiomeric separation could be achieved in the normal polarity mode. Different beta-cyclodextrin derivatives were first tested at a given concentration. Five derivatives were found to be particularly useful for enantioseparations in capillary electrophoresis (CE): the anionic carboxymethyl-beta-CD (CMCD) and sulfobutyl-beta-CD (SBCD) and the neutral dimethyl-beta-CD (DMCD), trimethyl-beta-CD (TMCD) and hydroxypropyl-beta-CD (HPCD). After selection of the most suitable CD, its concentration was optimized with respect to chiral resolution. If necessary, a further improvement in resolution could often be obtained for the enantiomers of cationic solutes by increasing the buffer pH from 3 to 5 using CMCD as chiral additive. Another possible alternative for enhancement in chiral resolution was the addition of metharlol or cyclohexanol to the buffer. For acidic drugs, essentially present in uncharged form at pH 3, and for neutral solutes, anionic CD derivatives such as SBCD or CMCD were first tested at a given concentration in the reversed polarity mode. Dual systems, based on the simultaneous addition of a charged CD (SBCD or CMCD) and a neutral CD (TMCD or DMCD), could then be investigated for resolution improvement. After optimization of the CD concentrations, the use of dual systems with CMCD at pH 5 could also be tested if necessary, especially for very weak acidic and neutral drugs. By applying these optimization strategies, 48 of the 50 drugs examined as model compounds could be fully enantioseparated by CE in short analysis times (usually less than 10 min).

Cyclodextrins↗

Enantiomeric separation of pirlindole by liquid chromatography using different types of chiral stationary phases.

The enantioseparation of pirlindole by liquid chromatography (LC) was investigated using three different chiral stationary phases (CSPs) containing either cellulose tris-(3,5-dimethylphenylcarbamate) (Chiralcel OD-R), ovomucoid (OVM) or beta-cyclodextrin (beta-CD). The effects of the mobile phase pH on retention, enantioselectivity and resolution were studied. Methanol and acetonitrile were tested as organic modifiers while the influence of the addition to the mobile phase of sodium alkanesulfonates or sodium perchlorate was also investigated. Sodium perchlorate was only used on the Chiralcel OD-R column while sodium alkanesulfonates were tested as mobile phase additives on the three kinds of CSPs. The enantioseparation of pirlindole could be obtained on all CSPs tested, the best results with respect to chiral resolution being achieved on the Chiralcel OD-R and the OVM columns. The use of sodium octanesulfonate (NaOS) was found to improve the enantioseparation of pirlindole on the OVM column while enantioselectivity was considerably enhanced by addition of sodium perchlorate on the Chiralcel OD-R column.

Carbamates↗

Stereoselective determination of S-naproxen in tablets by capillary electrophoresis.

A capillary electrophoresis (CE) method was developed for the stereoselective determination of the non-steroidal anti-inflammatory drug (NSAID), S-naproxen, in tablets. Several beta-cyclodextrin derivatives (CDs) were tested as chiral selectors, including sulfobutyl-beta-CD (SBCD), carboxymethyl-beta-CD (CMCD), dimethyl-beta-CD (DMCD) and trimethyl-beta-CD (TMCD), in a phosphoric acid/triethanolamine pH 3 buffer. Under these conditions, the analyte was mainly present in an uncharged form and therefore, the use a neutral CD (DMCD or TMCD) alone could not lead to enantiomeric separation. On the contrary, by addition of a charged CD (SBCD or CMCD) to the running buffer, giving the analyte enantiomers an adequate mobility, chiral resolution could be achieved, although the resolution values obtained in this case were not quite satisfactory (Rs < 1.5). Dual systems, based on the use of mixtures of charged and neutral CDs, were then investigated. The SBCD/TMCD system was found to be particularly well suited to the enantioseparation of naproxen and after optimisation of the concentrations of both CDs, a resolution value of 5.4 could be obtained. The method was validated for the determination of R-naproxen (enantiomeric impurity) in the 0.1-2% range, using the racemic mixture of the analyte. A second validation was performed in the 50-150% range for the quantitation of S-naproxen. In both cases, good results with respect to linearity, precision and accuracy were obtained.

Electrophoresis, Capillary↗

Automated determination of tramadol enantiomers in human plasma using solid-phase extraction in combination with chiral liquid chromatography.

A sensitive and automated method for the separation and individual determination of tramadol enantiomers in plasma has been developed using solid-phase extraction (SPE) on disposable extraction cartridges (DECs) in combination with chiral liquid chromatography (LC). The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with ethyl silica (50 mg) was first conditioned with methanol and phosphate buffer, pH 7.4. A 1.0-ml volume of plasma was then applied on the DEC. The washing step was performed with the same buffer. The analytes were eluted with 0.15 ml of methanol, and 0.35 ml of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) were added to the extract before injection into the LC system. The enantiomeric separation of tramadol was achieved using a Chiralcel OD-R column containing cellulose tris-(3,5-dimethylphenylcarbamate) as chiral stationary phase. The mobile phase was a mixture of phosphate buffer, pH 6.0, containing sodium perchlorate (0.2 M) and acetonitrile (75:25). The mobile-phase pH and the NaClO4 concentration were optimized with respect to enantiomeric resolution. The method developed was validated. Recoveries for both enantiomers of tramadol were about 100%. The method was found to be linear in the 2.5-150 ng/ml concentration range [r2=0.999 for (+)- and (-)-tramadol]. The repeatability and intermediate precision at a concentration of 50 ng/ml were 6.5 and 8.7% for (+)-tramadol and 6.1 and 7.6% for (-)-tramadol, respectively.

Analgesics, Opioid↗

Enantioseparation of nonsteroidal anti-inflammatory drugs by capillary electrophoresis using mixtures of anionic and uncharged beta-cyclodextrins as chiral additives.

Nine nonsteroidal anti-inflammatory drugs (NSAIDs) were enantioseparated by capillary electrophoresis using an anionic cyclodextrin derivative (sulfobutyl ether beta-cyclodextrin or carboxymethyl-beta-cyclodextrin) in combination with a neutral cyclodextrin as chiral additives to a pH 3 phosphoric acid-triethanolamine buffer. In the presence of a negatively charged cyclodextrin, the analytes were given an appropriate mobility but relatively low enantioselectivities were generally obtained when such a cyclodextrin was the only selector added to the buffer. The addition of an uncharged cyclodextrin, such as the native beta-cyclodextrin or one of its derivatives (dimethyl-, trimethyl- and hydroxypropyl-beta-cyclodextrin), to this kind of buffer containing an anionic cyclodextrin, was found to give rise to considerable improvement in chiral resolution for all compounds studied. Resolution and analysis time were optimized by varying the nature and concentration of the two cyclodextrins. The best compromise was usually achieved by the simultaneous addition of sulfobutyl ether beta-cyclodextrin and trimethyl-beta-cyclodextrin. Under optimum conditions, the enantiomers of all NSAIDs examined could be completely separated (most often with resolution values higher than 5) in short analysis times (generally lower than 15 min).

Anions↗

Enantioselective determination of oxprenolol in human plasma using dialysis coupled on-line to reversed-phase chiral liquid chromatography.

A fully automated method for the determination of the enantiomers of oxprenolol in human plasma was developed, involving dialysis through a cellulose acetate membrane, clean-up and enrichment of the dialysate on a short precolumn and subsequent chiral liquid chromatographic (LC) analysis. All sample handling operations were executed automatically by a sample processor equipped with a robotic arm (ASTED system). The trace enrichment column (TEC) was packed with octadecylsilica. After conditioning of the TEC with the LC mobile phase and pH 3.0 acetate buffer. After the enrichment step, the analyte was transferred by the LC mobile phase to the analytical column by means of a switching valve. The influence of different parameters of the dialysis process on the recovery of oxprenolol was first investigated using achiral LC conditions. The volume as well as the aspirating and dispensing flow rates of the acceptor solution were the main parameters studied. Oxprenolol was separated on a C18 stationary phase used for the enantioseparation of oxprenolol was a Chiralcel OD-R column which contained cellulose tris (3,5-dimethylphenylcarbamate) coated on silica as chiral selector. The corresponding mobile phase consisted of a mixture of pH 6.0 phosphate buffer containing NaClO4 at 0.45 M concentration and acetonitrile (70:30 v/v). UV detection was performed at 273 nm. The method developed was validated. Recoveries for each enantiomer of oxprenolol were about 80%. The method was found to be linear in the 50-2500 ng ml-1 concentration range (r2 = 0.999 for both enantiomers) and good results with respect to intra- and inter-day reproducibility as well as accuracy were obtained.

Adrenergic beta-Antagonists↗

Determination of six water-soluble vitamins in a pharmaceutical formulation by capillary electrophoresis.

A method was developed for the quantitative analysis of six water-soluble vitamins (thiamine, nicotinamide, riboflavine, pyridoxine, ascorbic acid and pantothenic acid) in a pharmaceutical formulation, using free solution capillary zone electrophoresis (CZE) in uncoated fused silica capillaries and UV detection. The influence of different parameters, such as the nature of the buffer anionic component and buffer concentration on the CZE separation of vitamins was investigated using four vitamins of the B group as model compounds. A good compromise between resolution, analysis time and analyte stability was obtained by use of a 50 mM borax buffer of pH 8.5. This CZE method was found to be very useful for the separation of more complex samples, a mixture of ten water-soluble vitamins being completely resolved in about 10 min. However, cyanocobalamine could not be separated from nicotinamide in this CZE system, the two compounds being in uncharged form at the pH used. These two compounds could easily be resolved by micellar electrokinetic chromatography (MEKC), the anionic surfactant dodecylsulfate being added to the running buffer at 25 mM concentration. In the pharmaceutical formulation, some excipients were found to be adsorbed to the capillary surface, giving rise to a progressive decrease of the electroosmotic flow and consequently to a simultaneous increase of analyte migration times. A capillary wash with sodium hydroxide had to be made between successive runs in order to minimize these effects. Good results with respect to linearity, precision and accuracy were obtained in the concentration range studied for the six vitamins, using nicotinic acid as internal standard.

Ascorbic Acid↗

Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection.

A fully automated method for the simultaneous determination of verapamil and its main metabolite norverapamil in human plasma is described. This method is based on on-line sample preparation using dialysis followed by clean-up and enrichment of the dialysate on a precolumn and subsequent HPLC analysis with fluorometric detection. All sample handling operations were performed automatically by a sample processor equipped with a robotic arm (ASTED system). The plasma samples were dialysed on a cellulose acetate membrane (cut-off: 15 kD) and the dialysate was purified and enriched on a short pre-column filled with cyanopropyl silica. Before starting dialysis, this trace enrichment column (TEC) was first conditioned with the HPLC mobile phase and then with pH 3.0 acetate buffer. 370 microliters of plasma sample spiked with the internal standard (gallopamil) were dialysed in the static-pulsed mode. The solution at the donor side was pH 3.0 acetate buffer containing Triton X-100 while the acceptor solution was made of the same acetate buffer. When dialysis was discontinued, the analytes were desorbed from the TEC by the HPLC mobile phase and transferred to the C18 analytical column by means of a switching valve. This mobile phase consisted of a mixture of acetonitrile, pH 3.0 acetate buffer and 2-aminoheptane. The influence of different parameters of the dialysis process on the recovery of verapamil and norverapamil has been studied. The effect of the volume, the aspirating and dispensing flow-rates of the dialysis solution has been investigated. The recoveries of verapamil and norverapamil in plasma were close to 75% and the limits of quantification were 5 ng/ml for both analytes. The method was found to be linear in the concentration range from 5 to 500 ng/ml (r2: 0.9996 for both analytes). The intra-day and inter-day reproducibilities at a concentration of 100 ng/ml were 2.3% and 5.6% for verapamil and 1.7% and 5.1% for norverapamil, respectively.

Calcium Channel Blockers↗

Resolution improvement by use of carboxymethyl-beta-cyclodextrin as chiral additive for the enantiomeric separation of basic drugs by capillary electrophoresis.

Three beta-cyclodextrin derivatives--carboxymethyl-, dimethyl- and hydroxypropyl-beta-cyclodextrin--were tested as chiral selectors for the enantioseparation of seven basic drugs in free solution capillary electrophoresis, using buffers made of 100 mM phosphoric acid adjusted to pH 3.0 with triethanolamine in fused silica capillaries thermostatted at 15 degrees C. The best results with respect to chiral resolution were obtained with carboxymethyl-beta-cyclodextrin (CMCD): the enantiomers of all compounds examined were completely resolved with this beta-cyclodextrin derivative. The influence of the CMCD concentration on the migration times, the apparent electrophoretic mobility difference and the resolution of the drug enantiomers was investigated thoroughly. Particularly impressive resolution values, up to 23.7, were obtained for several compounds in these capillary electrophoretic systems, using CMCD in the 5-15 mM concentration range.

Anesthetics, Local↗

Quantitative analysis of non-steroidal anti-inflammatory drugs by capillary zone electrophoresis.

The potential utility of capillary zone electrophoresis (CZE) for the separation and quantitative determination of some non-steroidal anti-inflammatory drugs (NSAIDs) was investigated. The influence of different parameters on migration times, peak symmetry, efficiency and resolution was studied; these parameters included the nature and concentration of the anionic and cationic components of the separation buffer. A buffer consisting of 75 mM glycine adjusted to pH 9.1 with triethanolamine was found to provide a very efficient and stable electrophoretic system for the CZE analysis of NSAIDs, giving RSD values of about 0.1 and 0.5% for the within-day reproducibility of migration times and peak areas, respectively at a concentration of 25 micrograms ml-1 (n = 5). Response was linear from 2-100 micrograms ml-1 for both sulindac and tiaprofenic acid, for which the LOQ values were 2.8 and 1.9 micrograms ml-1, respectively, using UV detection at 280 nm. Accuracy for each drug was 102-103%.

Anti-Inflammatory Agents, Non-Steroidal↗