PubMed Health⌕ Search

Biomedical subjects

J D Andrade

Publications and source records attributed to J D Andrade.

At least 19 recordsLinked to original sources

Phytic acid as an efficient low-molecular-mass displacer for anion-exchange displacement chromatography of proteins.

Phytic acid, inositol-hexaphosphoric acid, molecular mass 650, a low-molecular-mass compound, has been identified as a nearly ideal displacer in anion-exchange displacement chromatography for the concentration and purification of model protein mixture. The concentration of low-molecular-mass displacer is a very important parameter for successful separation by displacement chromatography. Displacer concentration influences the formation of the isotachic train and the yield and recovery of the displacement chromatographic process. There is an optimum displacer concentration in which the yield and recovery are highest.

Anion Exchange Resins↗

Bioluminescence as a classroom tool for scientist volunteers.

There is a great need for practicing scientists to volunteer their time and expertise in the K-12th grade science classroom. We have found that bioluminescence is a fun and exciting way to teach basic science concepts and is an excellent tool for the volunteering scientist. We have had very positive reactions from both teachers and students. The excitement of the students when they first see bioluminescence is contagious. Bioluminescent dinoflagellates are one of the easiest ways to introduce students to this fascinating topic. Many activities and experiments can be done using the bioluminescent dinoflagellates and many students and teachers could benefit from your knowledge and expertise. See you in the classroom.

Luminescent Measurements↗

Specific immobilization of in vivo biotinylated bacterial luciferase and FMN:NAD(P)H oxidoreductase.

Bacterial bioluminescence, catalyzed by FMN:NAD(P)H oxidoreductase and luciferase, has been used as an analytical tool for quantitating the substrates of NAD(P)H-dependent enzymes. The development of inexpensive and sensitive biosensors based on bacterial bioluminescence would benefit from a method to immobilize the oxidoreductase and luciferase with high specific activity. Toward this end, oxidoreductase and luciferase were fused with a segment of biotin carboxy carrier protein and produced in Escherichia coli. The in vivo biotinylated luciferase and oxidoreductase were immobilized on avidin-conjugated agarose beads with little loss of activity. Coimmobilized enzymes had eight times higher bioluminescence activity than the free enzymes at low enzyme concentration and high NADH concentration. In addition, the immobilized enzymes were more stable than the free enzymes. This immobilization method is also useful to control enzyme orientation, which could increase the efficiency of sequentially operating enzymes like the oxidoreductase-luciferase system.

Acetyl-CoA Carboxylase↗

Thin-layer ion-exchange chromatography of proteins.

Thin-layer chromatography (TLC) is one of the simplest and most convenient techniques to separate small molecules. Of a variety of TLC separation modes, only size-exclusion was successfully used to separate proteins. In this paper, adsorption-TLC was used to separate proteins. The net charges were calculated for four model proteins, albumin, transferrin, lactoferrin and lysozyme, under different pH values. The suitable pH values for separation were determined according to the results from such calculations. Then, the adsorption isotherms of the four proteins were measured to deduce the ionic strength for appropriate elution conditions. Optimal conditions, 0.01 M bicine and pH 8.50, and a three-step elution process (1st step 0.01 M NaCl, 2nd 0.025 M NaCl, and 3rd 0.10 M NaCl), were obtained. Finally, the four model proteins were successfully separated under these elution condition.

Adsorption↗

Specific immobilization of firefly luciferase through a biotin carboxyl carrier protein domain.

Firefly luciferase (Photinus pyralis) was fused with a histidine tag and a biotin carboxyl carrier protein (BCCP) domain at its amino terminus. Highly purified recombinant luciferase was obtained by a one-step purification protocol, utilizing immobilized metal affinity chromatography. The novel BCCP-luciferase had properties, stability, and activity similar to those of native luciferase. The biotin molecule on the BCCP domain allowed specific immobilization of BCCP-luciferase on avidin-coated surfaces via the biotin-avidin interaction.

Acetyl-CoA Carboxylase↗

Minimizing interferences in the quantitative multielement analysis of trace elements in biological fluids by inductively coupled plasma mass spectrometry.

The determination of trace and ultratrace elements in biological fluids, including urine and serum, by inductively coupled plasma mass spectrometry (ICP-MS) is discussed. Nonspectral interferences and their corrections by external calibration and calibrator addition are discussed in detail. External calibration with internal calibration and dilution is mostly sufficient to correct for encountered biological matrix effects. For some elements, such as Cs and Zn, the use of calibrator addition provides more accurate results. The importance of spectral interferences and their elimination by isotope selection was also studied. Two examples, Cu and Zn, demonstrate the prime importance of selecting an isotope with minimal polyatomic interferences for analysis. By using 65Cu and 68Zn, accurate results for urine and serum can be obtained without excessive pretreatment of samples. Two reference materials, Bio-Rad Lyphochek urine and Kaulson Contox sera, were analyzed. Accuracy was evaluated by comparison with target values, and precision was estimated by the CV within 95% confidence.

Calibration↗

Photoaffinity labeling of antibodies for applications in homogeneous fluoroimmunoassays.

A homogeneous noncompetitive immunoassay based on photoaffinity labeling techniques is described. Using this method, a fluorophore (reporter) can be specifically attached to an antibody in the vicinity of its antigen-combining sites. Upon antigen binding, changes in the fluorescence spectrum of the reporter molecule are often observed. Two fluorophores, pyrene and dansyl, were evaluated for this purpose. Also, this technology is ideal for fluorescence energy-transfer immunoassays that require labeling of the antibody with either a donor or acceptor fluorophore. In such cases, a fluorescent dye can be specifically attached near the antigen-combining site, where it can participate in high-efficiency energy transfer with its complementary fluorophore attached to the antigen.

Affinity Labels↗

Protein adsorption on low temperature isotropic carbon: V. How is it related to its blood compatibility?

Based on our research on blood protein interactions with low temperature isotropic carbon (LTIC) and data from the literature, we propose that the carbon surface has strong interactions with adsorbed proteins. In this paper we focus on how a relatively blood-compatible material interacts with plasma proteins. We present our results on the structure and properties of the LTIC surface utilizing SEM, STM, XPS, and contact angle measurements. We briefly review protein adsorption on LTIC using DSC, impedance, radioisotopes, and two-dimensional gel electrophoresis. LTIC is characterized by a microporous, oxidized, hydrophobic, and domain mosaic structure. Surface polishing smoothens the roughness and removes the porosity, while largely destroying the ordered atomic texture, making the surface more random and more amorphous. The LTIC surface denatures all adsorbed proteins studied. The rate of protein adsorption is high and the surface concentration is large. The LTIC surface adsorbs all proteins without preference. The surface also tenaciously retains proteins such that they cannot be displaced by buffer or exchanged by proteins in solution. We conclude that LTIC accomplishes its blood compatibility through a passivating film of strongly adsorbed bland proteins, which do not interact with platelets nor participate in blood coagulation. We also suggest mechanisms for the production of such a film by the LTIC surface.

Adsorption↗

Protein adsorption on low-temperature isotropic carbon: I. Protein conformational change probed by differential scanning calorimetry.

This is the first of a set of articles on protein adsorption on low-temperature isotropic carbon (LTIC), a reputed blood compatible material. Surface-induced conformational changes of albumin, fibrinogen, and some small proteins were measured by differential scanning calorimetry (DSC) on LTIC powders and colloidal silica. The LTIC surface significantly alters the DSC response (denaturation?) in proteins studied in different buffer solutions. We use the term "denaturation" to refer to altered protein behavior in the adsorbed state. Hydrophobic interactions between LTIC and the proteins are thought to be the major driving force. The presence of air at the water-carbon interface seems to prevent the surface denaturation of fibrinogen. The silica surface greatly denatures albumin but only slightly denatures fibrinogen. Because LTIC is considered to be a nonthrombogenic material, but silica is considered to be a thrombogenic one, whether a surface denatures adsorbed proteins cannot be the sole criterion for its blood compatibility. The latter largely depends on what protein the surface denatures, and in what sequences.

Adsorption↗

Protein adsorption on low temperature isotropic carbon. III. Isotherms, competitivity, desorption and exchange of human albumin and fibrinogen.

In this paper we consider the adsorption of albumin and fibrinogen on low temperature isotropic carbon (LTIC). A subsequent paper considers the adsorption of other plasma proteins [Feng L, Andrade JD, Colloids and Surfaces (in press)]. Carbon fragments and silica plates were used as adsorbents. Adsorption was carried out by incubating the adsorbents in solutions of 125I-labelled and unlabelled proteins (single component system), or with buffer-diluted human plasma (multicomponent system). Adsorbed proteins then underwent displacement by buffer, by single protein solutions or by dilute plasma. Results show that the LTIC substrate adsorbs a large amount of proteins before saturation, which may be due to multilayer adsorption. LTIC also irreversibly holds adsorbed proteins against the exchange agents used; little adsorbed proteins can be displaced, even after a very short adsorption time. There is no preferential adsorption for either albumin or fibrinogen on LTIC from their binary solutions, suggesting that both proteins have high affinities for the surface. Such strong interactions between LTIC and proteins are not attributed to electrostatic interactions. On the other hand, protein adsorption on the silica surface is selective and reversible, with a much higher affinity for fibrinogen than albumin and an even higher affinity for some other plasma proteins. The paper also discusses the effect of sequential protein addition to a solution on the surface concentration and suppression of adsorption of both proteins in the presence of other plasma proteins. A very important conclusion is that the LTIC surface is very active towards proteins adsorption.

Adsorption↗

Surface atomic and domain structures of biomedical carbons observed by scanning tunneling microscopy (STM).

STM has been used to study the surface domain and atomic structures of three biomedical carbons: glassy carbon (GC), low-temperature isotropic carbon (LTI), and ultra-low-temperature isotropic carbon (ULTI). The images show atomic lattices on both GC and LTI, but not on ULTI. The lattices contain many defects; lattices in GC are more ordered than those in LTI. The images also show patchlike carbon crystallites with sizes of 3-15 nm for GC, 2-8 nm for LTI, and 1-3 nm for ULTI. The crystallites from surface domains that may differ in surface properties due to different orientations of the crystallites. Mechanical polishing makes the LTI surface more amorphous and more homogeneous. Based on the STM observations, we evaluate several hypotheses on the blood compatibility of biomedical carbons.

Biocompatible Materials↗

Needs, problems, and opportunities in biomaterials and biocompatibility.

There are four topics related to biomaterials and biocompatibility which I feel are key problems, are often unrecognized, and are therefore rich opportunities for work in the near future: (i) the covalent instability of proteins, (ii) the concept of statistical specificity and statistical heterogeneity, (iii) the issue of solid surface dynamics and surface relaxation, and (iv) the growing concern with the costs of health care and of medical research. Each is briefly discussed in this paper.

Biocompatible Materials↗

Interaction of plasma proteins with heparinized gel particles studied by high-resolution two-dimensional gel electrophoresis.

In order to further the understanding of protein-surface interactions in the coagulation system, we have chosen to study plasma protein adsorption onto heparin-immobilized surfaces. Heparin-binding proteins are abundant in plasma: a search of amino acid sequences revealed that many plasma proteins have possible heparin binding sites. Plasma protein adsorption to the heparinized surfaces is monitored by a novel technique in which the solution depletion of proteins is analytically determined using quantitative two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). This method enables simultaneous, quantitative detection of the majority of plasma proteins before, during, and after their adsorption onto high surface area adsorbents. Using computerized densitometry of silver-stained 2-D PAGE gels, the amount of each protein can be determined from the integrated optical density of each protein "spot." Kinetics of adsorption and adsorption isotherms of four important heparin binding proteins, antithrombin III (ATIII), complement factor C3 (C3), apolipoprotein AI (Apo-AI) and apolipoprotein AIV (Apo-AIV) are reported in this paper. From the adsorption isotherms, the apparent binding constants of each protein-immobilized heparin complex, Ka, were calculated. The surface binding constants were of the same order of magnitude as the respective solution binding constants in the literature. The surface binding constants followed the same order as the respective solution binding constants: Ka (ATIII) greater than Ka (Apo-AIV) greater than Ka (C3) greater than Ka (Apo-AI), indicating that protein binding to the immobilized heparin used is not essentially different from solution binding.

Adsorption↗

Vroman effects, techniques, and philosophies.

Leo Vroman's work on blood-materials interaction over the years has motivated and influenced much of our work in this field. Here we show how most of our studies on proteins at interfaces can be traced to Vroman's ideas presented in Blood over 25 years ago. Specifically, we briefly discuss simple proteins at simple interfaces, complex interfaces, complex proteins at interfaces, multi-parameter phenomena, and scientific communication and education.

Biocompatible Materials↗

Surface properties of copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates and their application as protein-resistant coatings.

New polymeric surfactants, copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates, were synthesized and characterized by gel permeation chromatography. They were studied as possible means to produce polyethylene oxide-rich surfaces by a simple coating treatment on common hydrophobic medical materials. They were further studied as cleaners for the removal of proteins preadsorbed on hydrophobic surfaces. The surface properties of the copolymers such as the adsorption properties of the copolymer on a hydrophobic surface, low density polyethylene, the protein-resistant character of the prepared polyethylene oxide surfaces and the effectiveness of the copolymers for removal of proteins pre-adsorbed on the surface, were investigated by X-ray photoelectron spectroscopy and by using 125I-labelled copolymers and 125I-labelled proteins. The surface properties of the synthesized copolymers were compared with those of commercially available polyethylene oxide containing block copolymer surfactants.

Adsorption↗

Spatially resolved detection of antibody-antigen reaction on solid/liquid interface using total internal reflection excited antigen fluorescence and charge-coupled device detection.

Spatially-resolved detection of antibody-antigen reactions at the solid/liquid interface was investigated by total internal reflection excited fluorescence from large area flat surfaces. Anti-HSA immunoglobulin G (IgG) antibody was immobilized at four spatially distinct spots. Binding of fluorescein-labeled human serum albumin (HSA) from the solution to immobilized antibody was detected by a cooled charge-coupled device (CCD) as a charge in the fluorescence intensity. A two-dimensional representation of the fluorescence was obtained during the binding reaction time of 25 mins. The contributions from bound and free antigen to the total signal were evaluated. The influence of the scattered excitation light and the normalization of fluorescence signal with respect to the two-dimensional incident light intensity distribution are discussed.

Antigen-Antibody Reactions↗

The influence of adsorption of native and modified antibodies on their activity.

Immobilization of biomolecules to solid phase materials has been widely used in many areas (e.g., purification, analytical chemistry, and catalysis). The interfacial properties of immobilized antibodies on pretreated silica and hydrogel surfaces were explored by comparing native and modified antibodies with respect to their surface activity. The antibody was modified by exposing it to a low pH solution prior to immobilization. Both physical adsorption and covalent immobilization methods were studied. It was found that the surface activity of the modified antibody is higher than that of the native antibody on two silica surfaces. The results of this study demonstrate that the adsorption properties of the antibodies play an important role in their covalent immobilization on certain types of solid supports.

Adsorption↗

Protein-resistant surfaces prepared by PEO-containing block copolymer surfactants.

Polyethylene oxide(PEO)-containing nonionic polymeric surfactants were studied as a possible means to produce PEO-rich surfaces by a simple coating treatment of a common hydrophobic medical material--polyethylene. Surface tension and adsorption properties of PEO/polypropylene oxide(PPO) and PEO/polybutylene oxide(PBO) block copolymer surfactants on a hydrophobic surface (low density polyethylene, LDPE) were investigated, using the Wilhelmy plate surface tension technique and x-ray photoelectron spectroscopy(XPS). The protein resistance of the surfactant-treated surfaces was evaluated by XPS and 125I-labeled proteins. The data presented indicate that adsorption of the surfactants on LDPE is dependent on the molecular geometry of the surfactants. Adsorption of human albumin was significantly decreased on the surfactant-treated LDPE surfaces, as compared with the untreated surface. Surfactants suitable for the preparation of PEO-rich surfaces and possible mechanisms for their protein resistance are discussed.

Adsorption↗