PubMed HealthSearch

Biomedical subjects

J D Friedman

Publications and source records attributed to J D Friedman.

8 recordsLinked to original sources

Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation.

Prone 201Tl myocardial perfusion SPECT has been shown to improve left ventricular inferior wall counts compared to supine imaging, thus minimizing diaphragmatic attenuation. Prone SPECT quantitative normal limits were developed and prospectively applied to 36 patients who had coronary angiography. The prone imaging table used had a cut-out under cardiac area which increased the average myocardial counts by 10.7% compared to prone SPECT through the standard table. Overall specificity and sensitivity were 80% and 93%, respectively. For the right, left circumflex and left anterior descending coronary arteries, the specificities were 94%, 71%, and 94%; and sensitivities were 88%, 89% and 78%, respectively. The normalcy rate in 55 normal patients was 89%. Incidence and the severity of patients motion in 200 prone SPECT studies were compared to 200 supine SPECT studies. Mild and severe motion occurred in 12% and 4% of the supine studies and in only 3.5% and none of the prone studies, respectively. When compared to supine SPECT, prone SPECT had higher (p less than 0.01) regional counts/pixel in the inferior wall and septum, but required an average increase of 2.9 +/- 1.0 cm in camera to chest wall distance and resulted in a reduction of total myocardial counts. Prone SPECT provides an alternative approach for patients who cannot tolerate supine imaging. It should be considered when inferior wall defects on supine imaging pose a diagnostic dilemma and when motion on supine imaging necessitates repeat acquisition.

Aged

Frequency of late reversibility in stress-redistribution thallium-201 SPECT using an early reinjection protocol.

To assess the efficacy of an early thallium-201 reinjection protocol for reducing the need for late redistribution imaging, the frequency of thallium-201 late reversibility was prospectively assessed in 62 patients who had stress-redistribution thallium-201 studies by single-photon emission computerized tomography (SPECT), and who received 1 mCi of thallium-201 reinjection immediately following stress tomographic acquisition. These patients also demonstrated greater than or equal to 2 segments with nonreversible defects at 4-hour imaging and underwent late (18-to 72-hour) redistribution imaging. When the criterion of late reversibility was defined as greater than or equal to 1 segment with a 4-hour nonreversible defect demonstrating late reversibility, late reversibility was present in 36 (58%) of the 62 patients and in 88 (24%) of 368 SPECT segments. When the criterion of greater than or equal to 2 segments was used, late reversibility was found in 21 (34%) of the 62 patients and in 73 (20%) of the 368 segments. Of the 21 patients who had greater than or equal to 2 late reversible segments, 12 (57%) exhibited late reversibility in greater than or equal to 3 segments. The frequency of detected reversible defects increased from 32% by 4-hour imaging to 48% by combined 4-hour and late imaging (p less than 0.0001). The patients who demonstrated late reversibility could not be distinguished from those who had only late nonreversible defects by analysis of the clinical, exercise, and electrocardiographic (ECG) variables.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

A new approach to the assessment of tomographic thallium-201 scintigraphy in patients with left bundle branch block.

To determine whether a new approach to interpretation could improve the accuracy of thallium-201 single photon emission computed tomography (SPECT) for detection of left anterior descending coronary artery disease in patients with left bundle branch block, 69 patients were evaluated. Forty-four had angiographically proved coronary artery disease; the remaining 25 were considered to have a "low" (mean 13.5 +/- 6.4%, range 3.4% to 24.9%) likelihood of disease before thallium-201 scintigraphy. The conventional scintigraphic criterion for detection of left anterior descending artery disease (septal, anterior or apical defects) was compared with a new criterion that required the apex to be abnormal to indicate left anterior descending disease. The normalcy rates in the low likelihood patient group were significantly improved by using the new approach, from 16% to 80% (p less than 0.0001) by visual analysis and from 24% to 64% (p = 0.003) by quantitative SPECT polar map analysis. The sensitivity for left anterior descending disease was similar for the conventional and the new method by visual (100% vs. 94%) and quantitative (100% vs. 83%) analyses. In contrast, the specificity was significantly improved by using the new approach, from 14% to 79% (p = 0.0006) by visual analysis and 14% to 64% (p = 0.007) by quantitative analysis. In conclusion, septal and anterior thallium-201 SPECT defects are common in patients with left bundle branch block without coronary artery disease, resulting in low specificity for left anterior descending artery disease. The normalcy rates and accuracy for detection of left anterior descending coronary artery disease were significantly better when an apical defect was used as the criterion for disease.

Aged

Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease.

The clinical diagnostic accuracy of 2-day stress/rest quantitative Technetium-99m (Tc-99m) methoxy-isobutyl-isonitrile (Tc-sestamibi) single photon emission computerized tomography (SPECT) was assessed in a validation population of 61 patients from two different sites using two different camera/computer systems. The study population was made up of 53 catheterized patients, 29 from Cedars-Sinai Medical Center (CSMC) and 24 from the University of Texas Southwestern Medical Center (UTSMC), and eight UTSMC patients with a less than 5% pre-test likelihood of coronary artery disease. Interpretation employed gender-specific normal limits developed in an additional 15 men and 8 women at CSMC with less than a 5% likelihood of significant coronary artery disease. The results from CSMC compared with those from UTSMC were not different from each other. The overall sensitivity for detection of patients with coronary artery disease (greater than or equal to 50% stenosis) was 94% (CSMC: 92%, UTSMC: 95%). Overall specificity in the five patients with normal coronary arteriograms was 80% (CSMC: 67%, UTSMC: 100%). The normalcy rate in patients with a low likelihood of coronary artery disease was 88%. Vessel sensitivity was 85% (CSMC: 84%, UTSMC: 85%), while vessel specificity was 71% (CSMC: 72%, UTSMC: 69%). There was also no significant difference in the sensitivities and specificities between male and female populations. In addition, the agreement with coronary angiography for assessment of disease extent (normal coronary arteriogram, single or multivessel disease) was 75% (kappa = 0.6 +/- 0.1). This study demonstrated that Tc-sestamibi SPECT by quantitative analysis is accurate for the detection and localization of coronary artery disease. Furthermore, the CSMC quantitative method was shown to provide similar diagnostic accuracy when applied to data acquired at a different site using a different camera/computer system.

Adult

The frequency of late reversibility in SPECT thallium-201 stress-redistribution studies.

The frequency of thallium-201 late reversibility was prospectively assessed in 118 patients who had stress-redistribution thallium-201 studies by single photon emission computed tomography (SPECT). These patients demonstrated two or more segments with nonreversible defects at 4 h imaging and underwent late (18 to 72 h) redistribution imaging. When the criterion of late reversibility was defined as greater than or equal to 1 segment with 4 h nonreversible defects demonstrating late reversibility, it was present in 62 (53%) of the 118 patients and 164 (22%) of 762 segments. When the criterion of greater than or equal to 2 segments was used, late reversibility was found in 41 (35%) of 118 patients and 143 (19%) of 762 segments. The frequency of detected reversible defects increased from 27% at 4 h imaging to 43% at combined 4 h and late imaging (p less than 0.0001) and was significantly increased in all myocardial regions. In comparing the efficacy of initial and late imaging alone versus performing initial, 4 h and late imaging for the identification of reversible defects, 421 (94%) of 449 segments classified as reversible by the latter protocol were also correctly identified by the early and late imaging only approach, with the remaining 6% (28 segments) comprising those segments demonstrating the reversible pattern at 4 h and the nonreversible pattern at late imaging. No major differences were noted with respect to clinical, stress electrocardiographic and scintigraphic variables between the 118 patients undergoing late imaging and 98 additional randomly selected patients with two or more nonreversible defects at 4 h, who did not have late imaging.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Comparison of myocardial washout rate of thallium-201 between rest, dipyridamole with and without aminophylline, and exercise states in normal subjects.

The myocardial washout rate of thallium-201 was studied in 85 subjects with a less than 5% likelihood of coronary artery disease undergoing rest (group I, n = 12), dipyridamole (group II, n = 24) and exercise (group III, n = 49) stress thallium-201 scintigraphy. Subjects receiving dipyridamole were subdivided into group IIA (n = 11), who received an aminophylline injection 10 minutes after dipyridamole infusion, and group IIB (n = 13), who did not. The mean and highest washout rate values in each of 3 segments in the anterior, 45 degrees and 85 degrees left anterior oblique views were calculated. In group II the mean washout rate of thallium-201 was similar in all segments of each view and the overall mean washout rate did not differ between the 3 views studied. There was a good correlation between the mean and highest washout rate values in individual subjects (r = 0.98, p less than 0.001). The mean +/- standard deviation myocardial 4-hour washout rate of thallium-201 (anterior view) was 10 +/- 6% in group I compared with 40 +/- 14% in group IIA (p less than 0.05 vs group I), 31 +/- 13% in group IIB (p less than 0.05 vs group I) and 54 +/- 11% in group III (p less than 0.05 each vs group IIA and group IIB, respectively). There was a wide variation in mean washout rate values in group II (range 12 to 58%), and this variation was not altered by aminophylline administration.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Experience with colonic volvulus.

Fifty-eight cases of colonic volvulus were reviewed including 30 cases of sigmoid volvulus, 27 cases of cecal volvulus, and 1 of transverse colon volvulus. Decompression procedures were attempted in 31 instances of sigmoid volvulus in 27 patients and were successful 25 times (81 percent). Seven patients with sigmoid volvulus did not undergo surgery and of those, two died of unrelated causes, one was lost to follow-up, one was well, and three had recurrent volvulus. Twenty-four operations were performed on 23 patients and there were three deaths (13 percent mortality). There was one recurrence in two patients who underwent simple detorsion. Chronic large-bowel motility disturbances were a persistent problem in 9 of 20 (45 percent) surgical survivors. Among 27 instances of cecal volvulus, one was reduced by contrast enema and ten endoscopic attempts at decompression were unsuccessful. Twenty-six operations were done and there were four operative deaths (15 percent mortality). There were no recurrences. Large-bowel motility disorders were noted in follow-up in 3 of 22 patients (14 percent). Overall there were 10 deaths in 58 patients for a 17 percent mortality rate. These data support the importance of endoscopic decompression for sigmoid volvulus but not for cecal volvulus. Definitive treatment of both forms of volvulus should include assessment of colonic motility.

Adult

Quantitative analysis of stress thallium-201 myocardial scintigrams: a multicenter trial.

Previously we validated a method for quantification of 201TI myocardial stress distribution and washout in which the patient's stress and washout circumferential profiles are compared with observed normal limits. The present study reports the results of a multicenter trial in which this method, utilizing normal limits from our institution, was employed to evaluate the presence, location, and extent of coronary artery disease (CAD). The normal limits utilized were generated from 49 patients having a low likelihood of CAD. The study population included 157 patients from four centers in the United States and Canada as well as a comparative prospective population from Cedars-Sinai Medical Center (CSMC) of 51 patients with CAD, 30 patients with normal coronary arteriograms, and 30 additional low-likelihood normals. The results in the combined centers regarding overall detection of CAD revealed a sensitivity of 84% and a frequency of test normality in the patients with low likelihood of CAD of 88%, compared to a sensitivity of 82% and true normalcy rate of 83% obtained in the prospective CSMC population. The sensitivity for detecting disease increased according to the extent of angiographic CAD in both the multicenter sites and the prospective CSMC group. Regarding localization of disease, similar sensitivities and specificities for detecting disease in individual coronary arteries were found in the multicenter sites and the prospective CSMC population. The results indicate that our method for quantifying 201TI stress-redistribution scintigrams utilizing standard normal limits can be applied at other institutions using a variety of scintillation cameras with similar accuracy to that currently obtained at our institution.

Adult