PubMed HealthSearch

Biomedical subjects

J D Madison

Publications and source records attributed to J D Madison.

4 recordsLinked to original sources

Seismocardiographic changes associated with obstruction of coronary blood flow during balloon angioplasty.

Seismocardiography, a new noninvasive technique, detects low-frequency cardiac vibrations on the chest wall during ventricular contraction and during both early and late ventricular filling. To evaluate the ability of seismocardiography to detect ischemia caused by decreased coronary blood flow, 35 patients were studied during coronary angioplasty. Seismocardiograms and electrocardiograms were recorded twice at baseline, with the catheter across the lesion before first inflation (n = 15), every 30 seconds during the first inflation, 1 and 2 minutes after the first inflation and greater than or equal to 5 minutes after the final inflation. For comparison, sequential seismocardiograms were also obtained from 15 healthy volunteers. Electrocardiograms were blindly scored for ST change from baseline (0 = none, 1 = 0.5 mm ST depression, 2 = greater than or equal to 1.0 mm ST depression, 3 = ST elevation). Seismocardiograms were blindly scored for change from baseline (0 = none, 1 = mild, 2 = moderate, 3 = marked) for both the systolic and diastolic waves. The average maximal systolic seismocardiographic score was 2.5 +/- 0.8 for patients who had undergone angioplasty and 1.0 +/- 0.9 for volunteers (p less than 0.001). The average maximal diastolic seismocardiographic score was 2.3 +/- 0.8 for angioplasty patients and 0.7 +/- 0.9 for volunteers (p less than 0.001). The percentage of angioplasty patients with electrocardiographic, systolic and diastolic seismocardiographic scores greater than or equal to 2 was, respectively: 0, 11 and 14% at second baseline; 23, 67 and 53% with catheter across the lesion; 44, 75 and 59% after 30 seconds of inflation; 42, 71 and 61% after 60 seconds of inflation; 23, 74 and 61% after 1 minute of deflation; and 0, 71 and 47% 5 minutes after final inflation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Monorail Piccolino catheter: a new rapid exchange/ultralow profile coronary angioplasty system.

The Monorail Piccolino coronary angioplasty balloon catheter (MBC) was evaluated on 118 patients at two centers. Technical success was achieved in 110 patients (93%). Time for catheter exchange and total fluoroscopy time were significantly lower for the Monorail catheter than with standard equipment (exchange time 97 vs. 170 seconds P less than .05 and fluoroscopy time 17 vs. 88 seconds P less than .001). The advantages of rapid exchange and the ability of utilize 2 Monorail balloon catheters through one 9F guiding catheter for simultaneous inflations allowed for maximal flexibility in treating patients with bifurcation lesions. The double wire approach utilizing one Monorail balloon catheter with a 7F guiding catheter was also technically successful. The Monorail Piccolino balloon catheter has unique features that allow for greater ease of operator use, rapid catheter exchange, and optimal angiographic visualization. It is felt that this catheter design provides distinct advantages over standard angioplasty equipment.

Angiography