PubMed HealthSearch

Biomedical subjects

J D Marco

Publications and source records attributed to J D Marco.

18 recordsLinked to original sources

Pathologic bronchial vasculature in a case of massive hemoptysis due to chronic bronchitis.

The cause of bleeding in a patient with recurrent massive hemoptysis was not apparent after bronchoscopy and gross examination of the lobectomy specimen. Histologic submission of all major bronchi uncovered dilated, tortuous bronchial arteries just below the bronchial mucosa with sites of both current and healing arterial rupture. This bronchial arterial abnormality is common to several chronic pulmonary diseases, but is rarely diagnosed as a cause of massive hemoptysis. Careful pathologic examination of major bronchi in the setting of hemoptysis of unknown causation is recommended.

Aged

Determinants of homologous blood usage utilizing autologous platelet-rich plasma in cardiac operations.

The present study evaluated (1) the influence of the collection of autologous platelet-rich plasma intraoperatively in addition to intraoperative autotransfusion on homologous blood usage and bleeding in cardiac operations; (2) the influence of age, sex, body surface area, type of operation, and reoperations on homologous blood usage and bleeding in cardiac operations utilizing intraoperative autotransfusion and autologous platelet-rich plasma collected intraoperatively; and (3) the influence of the preoperative administration of aspirin, Persantine (dipyridamole), heparin sodium, thrombolytic agents, Coumadin (crystalline warfarin sodium), and nonsteroid, antiinflammatory drugs on homologous blood usage and bleeding in cardiac operations utilizing intraoperative autotransfusion and autologous platelet-rich plasma collected intraoperatively. The results demonstrated a decrease in homologous blood use and bleeding when autologous platelet-rich plasma is collected in addition to the use of intraoperative autotransfusion. All of the patient and procedural variables influenced homologous blood usage and bleeding to some extent. Only the thrombolytic agents affected blood usage by increasing homologous plasma usage. All other drugs evaluated did not influence blood utilization or the amount of bleeding intraoperatively or postoperatively.

Anti-Inflammatory Agents, Non-Steroidal

Autologous platelet-rich plasma in cardiac surgery: effect on intraoperative and postoperative transfusion requirements.

The Southern Arizona Red Cross Blood program, in conjunction with participating hospitals and cardiac surgeons, evaluated the effect of a program to harvest autologous platelet-rich plasma (PRP) from patients immediately prior to undergoing cardiopulmonary bypass surgery. The PRP was transfused back to the patient after heparin neutralization was achieved at the completion of cardiopulmonary bypass. The effect of this autologous PRP product on homologous plasma and platelet usage was examined. The study demonstrates a significant decrease in homologous plasma and platelet usage when autologous PRP is used in cardiac surgery.

Blood Transfusion

Intraoperative autotransfusion in cardiac operations. Effect on intraoperative and postoperative transfusion requirements.

The Southern Arizona Regional Red Cross Blood Program, in cooperation with two cardiac surgery groups, examined the effect of intraoperative autotransfusion on red cell, plasma, and platelet usage during and after cardiac operations. The study evaluated whether intraoperative autotransfusion influenced intraoperative or postoperative blood usage and whether regular use was more effective than selective use. The study demonstrated that intraoperative autotransfusion reduces intraoperative and postoperative blood use and that regular use of intraoperative autotransfusion is more effective than selective use.

Blood Transfusion

Afterload reduction with hydralazine following valve replacement.

Impedance reduction with hydralazine was evaluated in 23 patients 1 to 3 hours after aortic or mitral valve replacement. Patients were randomly assigned to Group 1 (0.25 mg/kg) or Group 2 (0.5 mg/kg) and responses at 20, 60, and 120 minutes compared with control (paired t test) and mean values for each group compared (t test). In Group 1 significant responses were the fall in mean arterial pressure (78.3 +/- 3.0 to 66.7 +/- 2.2 mm Hg) and systemic vascular resistance (2,808 +/- 264 to 1,823 +/- 164 dynes-sec/cm5); the increase in cardiac index (2.07 +/- 0.13 to 2.71 +/- 0.21 L/min/m2), stroke volume index (26.9 +/- 2.3 to 34.0 +/- 3.3 ml/beat), and heart rate (80.8 +/- 5.8 to 84.2 +/- 6.6 beats/min). Central venous pressure did not change and left atrial pressure decreased at 120 minutes. Group 2 responses were similar except for higher central venous pressure at 20 minutes, higher left atrial pressures at control, 20, and 60 minutes, and lower left ventricular stroke work at control, 20, and 60 minutes. By selectively dilating the arterial system, hydralazine reduces mean arterial pressure and systemic vascular resistance and increases cardiac output with suble filling pressures.

Aortic Valve

Pulmonary and left atrial hemodynamics in mital stenosis.

A laboratory model has been utilized to evaluate left atrial and pulmoanry hemodynamics while comparing atria of three different compliances, five valve orifices, four pulmonary complicances, two venous pressures, and a predetermined pulmonary vascular resistance. The data demonstrate significant relationships between these variables and cardiac output, pulmonary artery pressure, and left atrial pressure and between the variables themselves. The complexity of these interrelationships is consistent with the lack of simple linear relations between current clinical measurements and emphasizes the need for measurements of compliance if the hemodynamic consequences of mitral stenosis are to be better understood.

Blood Pressure

Topical cardiac hypothermia and phrenic nerve injury.

The relationship between ice-chip cardioplegia and impaired left diaphragmatic function was evaluated in dogs. Direct or indirect contact of the phrenic nerve with crushed ice for 30 or 60 minutes resulted in phrenic paralysis for 6 to 28 days, with responsiveness returning from 7 to 62 days later. Microscopical examination of injured nerves revealed injury to the myelin sheath and preservation of axons. Paralysis of the left diaphragm after topical cardiac hypothermia may be secondary to cold injury of the phrenic nerve, which is reversible.

Animals

Coronary venous arterialization: acute hemodynamic, metabolic, and chronic anatomical observations.

Nine dogs that had anastomosis of the internal mammary artery (IMA) to the left anterior descending coronary vein (LADV) were studied acutely on right-heart bypass. Occlusion of the left anterior descending coronary artery (LADA) and LADV without venous arterialization resulted in a significant decline in stroke work, total coronary flow, and myocardial oxygen uptake; with reactive hyperemia an increase in lactate and pyruvate consumption resulted. Occlusion of the LADA and LADV with VA did not change these variables greatly, except for a marked increase in total coronary flow with reactive hyperemia. Chronic venous arterialization in 14 dogs was associated with a 14% mortality, while 10 controls had a 40% mortality. Dogs were killed at six weeks, and prior angiography in 9 showed patency of the IMA to the heart without filling of cardiac veins. All dogs had infarcts in the distribution of the LADA; these infarcts were smaller in dogs with venous arterialization. The anastomoses were obliterated by mature or maturing fibrous tissue, with alteration of the vein so that it was frequently not discernible, while the IMA was well preserved. Distal veins had foci of intimal proliferation, subintimal fibrosis, and medial hypertrophy. Although venous arterialzaiton provides protection for the acutely ischemic myocardium, this effect does not persist, perhaps because of anastomotic occlusion due to fibrous proliferation.

Animals

Aortic venting. Comparison of vent effectiveness.

Three commercially available aortic vents have been evaluated as to effectiveness in removing small volumes of air introduced into a mock circulatory circuit. Without aspiration, Vent 2 was the most effective and removed 58 per cent of 0.1 ml., 90 per cent of 0.5 ml., and 74 per cent of 1.0 ml. boluses at a cardiac output of 2 L. At a cardiac output of 4 L., Vent 2 removed 42, 76, and 49 per cent, respectively. With aspiration (Vent 2 not designed for aspiration) and a 2 L. cardiac output, Vents 1 and 3 removed 84 to 98 per cent of 0.1 ml., 68 to 92 per cent of 0.5 ml., and 74 to 86 per cent of 1.0 ml. boluses. With aspiration and a 4 L. cardiac output, Vent 3 was significantly more effective than Vent 1 and removed 92 to 94 per cent of 0.1 ml., 82 to 86 per cent of 0.5 ml., and 77 to 80 per cent of 1.0 ml. boluses. One liter of canine blood was aspirated through Vents 1 and 3 and a flow rate of 250 ml. per minute. For Vent 1, serum hemoglobin levels increased from 40 to 249 mg. per 100 ml. and for Vent 3 from 49 to 212 mg. per 100 ml. There are significant differences in the ability of commercially available aortic vents to remove small air bubbles trapped in the heart after initial direct cardiac venting. Vents having the capability of aspiration are more effective and result in acceptable hemolysis.

Aorta

Left ventricular aneurysmectomy.

Comparison of preoperative and postoperative studies in 81 patients undergoing left ventricular aneurysmectomy failed to show consistent hemodynamic trends. The most reliable prognostic indicator for survival (84% early, 71% late) was the function of the basilar ventricular segments. In 62 of the 81 patients, there was concomitant aortocoronary bypass grafting. Eighty-eight percent of the surviving patients are essentially free of symptoms. These findings support the continued surgical treatment of ventricular aneurysm in symptomatic patients, and suggest nonoperative treatment for patients who are asymptomatic.

Coronary Artery Bypass

Intraaortic balloon assistance.

Intraaortic balloon (IAB) assistance in 64 patients over 2 1/2 years has resulted in a survival rate of 11% (1 patient) when used alone but 47% when utilized in patients treated surgically (long-term survival, 38% [21 patients]). Patients undergoing coronary artery bypass grafting or aortic valve replacement have a long-term survival of 50% (8 and 9 patients, respectively). The required duration of IAB support has a bearing on the clinical result. Complications have been minimal. Though it was originally developed to assist in the nonoperative management of complications of ischemic heart disease, IAB assistance offers significant promise as an adjuvant to operative therapy for both ischemic and valvular heart disease.

Aortic Valve

In favor of the Y-graft for aortocoronary bypass.

The technique of multiple coronary artery bypass grafting has included separate conduits, snake grafts, and Y-grafts. Against the Y-graft have been reports of lesser patency and several theoretical objections. The theory is discussed and a laboratory model presented which demonstrates a flow difference of 2 ml/5 sec or less between Y-grafts and single grafts. In conjunction with this, 171 patients having aortocoronary bypass were analyzed and showed a combined one-year graft patency of 77% with no significant difference between single grafts and Y-grafts. It is concluded that the technical simplicity of Y-grafts is advantageous and that, if the operation is performed within the guidelines set forth, revascularization with Y-grafts is an acceptable method.

Animals

A servocontrolled atrial-aortic assist device: experimental findings and clinical experience.

A servocontrol system was developed to regulate a single roller pump left atrial-aortic (La-A) assist device. Responsiveness of the servomechanism to blood volume changes, myocardial damage, and mitral regurgitation was evaluated in 5 sheep and 6 dogs. Myocardial damage was induced by occlusion of coronary arteries. and the hemodynamic effects of La-A assistance were evaluated. While La-A assistance reduced left atrial pressures to low levels, the left ventricular end-diastolic pressure remained elevated in the severely damaged heart. LaA-assistance was used in 3 patients. Two were weaned from cardiopulmonary bypass after failure of intraaortic balloon counterpulsation, and 1 is a long-term survivor. The third was supported for 48 hours after attempt repair of complex congenital heart disease. The servocontrol device added to the safety of prolonged La-A assistance. This mode of assistance should be considered when intraaortic balloon counterpulsation has failed.

Adolescent

Operative flow measurements and coronary bypass graft patency.

Early (one week) and late (one year) postoperative angiography was performed in 142 patients having 310 grafts (117 right coronary artery [RCA], 134 left anterior descending [LAD], and 59 circumflex coronary artery [CCA]) to assess the factors responsible for failure of aorta-coronary artery saphenous vein grafts. Early catheterization revealed an 85.5 per cent patency rate with similar rates for each artery (RCA 88 per cent, LAD 85 per cent, and CCA 81 per cent). At one year 238 grafts remained patent, for a cumulative patency rate of 76.8 per cent with a similar distribution for each vessel (RCA 75 per cent, LAD 78 per cent, and CCA 76 per cent). Intraoperative flow measurements were correlated with early and late patency. Grafts with a basal flow less than 20 ml. per minute have a 42 per cent early closure rate and a 21 per cent late closure rate (cumulative 63 per cent). A basal flow of less than 40 ml. per minute was associated with a 25 per cent early failure and an 11 per cent late failure rate (cumulative 36 per cent). Basal flow at levels greater than 40 ml. per minute was not associated with an increased probability of graft closure. Absence of reactive hyperemia (30 second graft occlusion) was associated with a 19 per cent probability of early closure and a 31 per cent probability of cumulative thrombosis. A papaverine-induced flow increase (15 mg. given into the graft) of less than 100 per cent over basal flow gave a 20 per cent probability of early failure and 30 per cent probability of cumulative closure. Thus intraoperative basal flow measurements are of predictive value in determining the fate of aorta-coronary artery vein bypass grafts, and vasodilatory maneuvers provide little additional information.

Coronary Artery Bypass

Implantable pacemakers in children.

Permanent pacemakers were implanted in 12 children, ages 2 weeks to 6 years. The cause of the arrhythmia was congenital in three, postoperative in six, viral in one, and unknown in two. One operative death occurred on the second postoperative day. Two late deaths occurred five and 10-1/2 years postoperatively. The late deaths were in patients with good cardiac capture in whom the block followed repair of tetralogy of Fallot. Ventricular arrhythmias were believed to be the cause of death. Reoperation was required 37 times: for pacemaker exhaustion, 17; electrode problems, 15; wound problems, four; and arrhythmia, one. Nine of 12 patients are alive nine months to ten years eight months postoperatively. The remaining three survived for eight to ten years. Frequent reoperation and dilligent correction of defective pacing is rewarded with long, active lives in children requiring implantable pacemakers.

Adolescent

The Blalock-Taussig shunt in the first six months of life.

Because of increasing interest in the application of the Blalock-Taussig shunt in smaller infants, we reviewed the course of 18 infants aged 6 months or less who underwent this procedure. The mortality rate in 4 infants under 2 weeks of age was 50 per cent and that in those 2 weeks to 6 months of age, 28 per cent. The patency rate was 70 per cent. Because of late problems with the Waterston shunt and a comparable mortality rate, the Blalock-Taussig procedure is recommended for all infants, except perhaps those under 2 weeks of age.

Female