Ventilation in public housing: implications for indoor nitrogen dioxide concentrations.

UNLABELLED: Although elevated nitrogen dioxide (NO2) exposures may exacerbate asthma, few studies have examined indoor NO2 levels in low-income, urban neighborhoods, where asthma prevalence is high. As part of the Healthy Public Housing Initiative, NO2 was measured in 77 homes within three Boston public housing developments, using Palmes tubes placed in the kitchen, living room, and outdoors. Air exchange rates (AERs) were assessed using a perfluorocarbon tracer technique. Overall NO2 levels were [mean (ppb)+/-s.d.]: kitchen (43+/-20, n=100), living room (36+/-17, n=102), outdoor (19+/-6, n=91). Indoor NO2 levels were significantly higher in the heating season (living room: 43 ppb vs. 26 ppb, kitchen: 50 ppb vs. 33 ppb), while AERs were significantly lower in the heating season (medians 0.49/h vs. 0.85/h). Significant univariate predictors of indoor concentrations include: outdoor NO2 levels, AERs, and occupancy. AERs and outdoor NO2 remained significant in multivariate models (P<0.05). A dummy variable for supplemental heating with gas stove was not significant (P=0.14), but had a large, positive coefficient. Indoor NO2 levels in this cohort are higher than those generally reported in residential US settings, associated in part with increased gas stove usage and decreased AERs during the heating season. PRACTICAL IMPLICATIONS: Indoor air quality is mainly a function of outdoor concentrations, indoor sources, ventilation, and residential behavior. Indoor exposures to nitrogen dioxide and other combustion pollutants may be elevated within low-income housing developments due to the presence of multiple sources, poor ventilation, small apartment size, and behavioral responses to apartment conditions (e.g. supplemental heating with gas stove). This information may be used by housing authorities and other landlords to decrease potential environmental stressors, through interventions such as source substitution and improved ventilation, particularly for sensitive sub-populations such as asthmatics.

Air Pollution, Indoor↗

Ozone exposures during trans-continental and trans-Pacific flights.

UNLABELLED: Ozone concentrations were passively monitored in passenger cabins of commercial airliners flying domestic, Pacific, and south-east Asian routes. One-hundred and six flight segments were monitored for either the full duration and/or approximately 3 h during the middle portion of the flight for a total of 145 time-integrated measurements. Over all samples the mean (+/-SD) concentration was 80 p.p.b. (30.1). Twenty percent of the measurements exceeded 100 p.p.b., the FAA-recommended level. Eleven percent of the measurements exceeded 120 p.p.b., the US EPA's short-term National Ambient Air Quality Standard for ozone. Ozone concentrations measured on Pacific flights were substantially higher during mid-flight than over the full flight (95 p.p.b. vs. 56 p.p.b). Ozone concentrations on the northern Pacific routes were higher than concentrations for other Pacific flights. Season comparison showed that ozone levels were higher during the winter and spring than for the summer and fall. Our study shows that even in aircraft with catalytic ozone converters, passengers and flight crew may be exposed to elevated ozone levels on domestic and international flights. Given the frequency of ozone excess, it is recommended that (1) ozone converters should be required equipment on all commercial passenger aircraft for mid and high latitude routes (2) improved maintenance procedures should be required for catalytic converters (e.g., more frequent servicing/replacement), and (3) ozone should be routinely monitored on all mid and high latitude flights. PRACTICAL IMPLICATIONS: The authors have demonstrated elevated ozone concentrations in passenger cabins. They give several practical recommendations to help solve the problem.

Air Pollution, Indoor↗

Particulate matter and lung function growth in children: a 3-yr follow-up study in Austrian schoolchildren.

The effects of particulate matter <10 microm in diameter (PM10) and other air pollutants on lung function were assessed in 975 schoolchildren, from eight communities in Lower Austria between 1994-1997. In each community, air pollution data were collected. Spirometry was performed twice a year. PM10 concentration (mean concentration between two subsequent lung-function measures in spring and autumn (summer interval) or between autumn and spring (winter interval)) showed a mean value of 17.36 microg x m(-3) in the summer interval and 21.03 microg m(-3) in the winter interval. A slower increase in the forced expiratory volume in one second (FEV1) and midexpiratory flow between 25 and 75% of the forced vital capacity (MEF25-75) with age in children exposed to higher summer PM10 was observed in the 3-yr study period. After adjusting for potential confounders (sex, atopy, passive smoking, initial height, height difference, site, initial lung function) an increase of summer PM10 by 10 microg x m(-3) was associated with a decrease in FEV1 growth of 84 mL x yr(-1) and 329 mL x s(-1) x yr(-1) for MEF25-75. Nitrogen dioxide and ozone also showed a negative effect on lung-function growth, confirming previous work. The authors concluded that long-term exposure to particulate matter <10 microm in diameter had a significant negative effect on lung-function proxy for the development of large (forced expiratory volume in one second) and small (midexpiratory flow between 25 and 75% of the forced vital capacity) airways, respectively, with strong evidence for a further effect of ozone and nitrogen dioxide on the development of forced vital capacity and forced expiratory volume in one second.

Air Pollutants↗

Identification of selected hormonally active agents and animal mammary carcinogens in commercial and residential air and dust samples.

In order to characterize typical indoor exposures to chemicals of interest for research on breast cancer and other hormonally mediated health outcomes, methods were developed to analyze air and dust for target compounds that have been identified as animal mammary carcinogens or hormonally active agents and that are used in commercial or consumer products or building materials. These methods were applied to a small number of residential and commercial environments to begin to characterize the extent of exposure to these classes of compounds. Phenolic compounds, including nonylphenol, octylphenol, bisphenol A, and the methoxychlor metabolite 2,2-bis(p-hydroxyphenyl)-1,1,1-trichloroethane (HPTE), were extracted, derivatized, and analyzed by gas chromatography/mass spectrometry (GC/MS)-selective ion monitoring (SIM). Selected phthalates, pesticides, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls (PCBs) were extracted and analyzed by GC/MS-SIM. Residential and workplace samples showed detectable levels of twelve pesticides in dust and seven in air samples. Phthalates were abundant in dust (0.3-524 micrograms/g) and air (0.005-2.8 micrograms/m3). Nonylphenol and its mono- and di-ethoxylates were prevalent in dust (0.82-14 micrograms/g) along with estrogenic phenols such as bisphenol A and o-phenyl phenol. In this 7-sample pilot study, 33 of 86 target compounds were detected in dust, and 24 of 57 target compounds were detected in air. In a single sample from one home, 27 of the target compounds were detected in dust and 15 in air, providing an indication of chemical mixtures to which humans are typically exposed.

Air Pollution, Indoor↗

Fine particulate matter and polycyclic aromatic hydrocarbon concentration patterns in Roxbury, Massachusetts: a community-based GIS analysis.

Given an elevated prevalence of respiratory disease and density of pollution sources, residents of Roxbury, Massachusetts, have been interested in better understanding their exposures to air pollution. To determine whether local transportation sources contribute significantly to exposures, we conducted a community-based pilot investigation to measure concentrations of fine particulate matter (particulate matter < 2.5 microm; PM(2.5)) and particle-bound polycyclic aromatic hydrocarbons (PAHs) in Roxbury in the summer of 1999. Community members carried portable monitors on the streets in a 1-mile radius around a large bus terminal to create a geographic information system (GIS) map of concentrations and gathered data on site characteristics that could predict ambient concentrations. Both PM(2.5) and PAH concentrations were greater during morning rush hours and on weekdays. In linear mixed-effects regressions controlling for temporal autocorrelation, PAH concentrations were significantly higher with closer proximity to the bus terminal (p < 0.05), and both pollutants were elevated, but not statistically significantly so, on bus routes. Regressions on a subset of measurements for which detailed site characteristics were gathered showed higher concentrations of both pollutants on roads reported to have heavy bus traffic. Although a more comprehensive monitoring protocol would be needed to develop robust predictive functions for air pollution, our study demonstrates that pollution patterns in an urban area can be characterized with limited monitoring equipment and that university-community partnerships can yield relevant exposure information.

Cities↗

Characteristics of sorption losses of polychlorinated biphenyl congeners onto glass surfaces.

Sorption losses to glass surfaces of five polychlorinated biphenyl (PCB) congeners in aqueous solutions were investigated. Adsorption/desorption experiments were conducted under conditions that simulated actual sample handling procedures for environmental samples. It was found that the adsorption loss is related to the degree of chlorination. PCB congener 180 lost the most onto glass surfaces, followed by congeners 138, 101/28, and 52, in decreasing order. More PCB adsorption occurred onto glass under conditions of agitation and higher temperature (22 degrees C) during the five-day experimental period. The salinity effect ("salting out effect") was also observed in this work. The efficiency of desorption (rinsing three times with solvent) was found to be ineffective in extracting adsorbed PCBs. It was necessary to use mechanical shaking for extraction. Storage of samples up to five days resulted in sorption losses as much as 30%, 17%, 30%, 40%, and 55% of PCB 28, 52, 101, 138, and 180, respectively. Sorption losses need to be considered when conducting water sampling or toxicological studies to avoid underestimation of the actual PCB concentrations and their toxic effects.

Adsorption↗

Coating effects on the glass adsorption of polychlorinated biphenyl (PCB) congeners.

The effects of coating materials on polychlorinated biphenyl (PCB) adsorption in aqueous solution were assessed in an attempt to minimize PCB sorption loss during sampling processes. A coating material, which enhances PCB adsorption and allows adsorbed PCBs to be readily extracted by solvents, can act as a sampling concentrator to reduce PCB losses from both adsorption and evaporation. Several coating materials were evaluated, including paraffin oil, silicone oil, dimethyldichlorosilane (Sylon-CT), Prosil 28 and polydimethylsiloxane (PDS) with viscosity 0.65, 50 (PDS 50), and 500 (PDS 500) cSt. PDS and silicone oil enhanced adsorption for all five congeners examined (IUPAC No. 28, 52, 101, 138, and 180). Sylon-CT, paraffin oil and Prosil 28 had inconsistent effects on adsorption of different congeners. Desorption of adsorbed PCBs onto all coating types was assessed. The recovery efficiency of extracting PCBs with solvents was enhanced greatly with all coatings as opposed to non-coated surfaces, with the exception of paraffin oil. Coating with silicon oil, PDS 50, and 500 resulted in virtually 100% recovery of adsorbed PCBs. It was also found that Teflon containers were poor substitutes for glass containers and failed to minimize PCB losses. Among the materials studied, the best coating that could be used as a sampling concentrator was PDS 500.

Adsorption↗

Estimating the mortality impacts of particulate matter: what can be learned from between-study variability?

Epidemiologic studies of the link between particulate matter (PM) concentrations and mortality rates have yielded a range of estimates, leading to disagreement about the magnitude of the relationship and the strength of the causal connection. Previous meta-analyses of this literature have provided pooled effect estimates, but have not addressed between-study variability that may be associated with analytical models, pollution patterns, and exposed populations. To determine whether study-specific factors can explain some of the variability in the time-series studies on mortality from particulate matter [less than/equal to] 10 microm in aerodynamic diameter (PM(10)), we applied an empirical Bayes meta-analysis. We estimate that mortality rates increase on average by 0.7% per 10 microg/m(3) increase in PM(10) concentrations, with greater effects at sites with higher ratios of particulate matter [less than/equal to] 2.5 microm in aerodynamic diameter (PM(2.5))/PM(10). This finding did not change with the inclusion of a number of potential confounders and effect modifiers, although there is some evidence that PM effects are influenced by climate, housing characteristics, demographics, and the presence of sulfur dioxide and ozone. Although further analysis would be needed to determine which factors causally influence the relationship between PM(10) and mortality, these findings can help guide future epidemiologic investigations and policy decisions.

Air Pollution↗

The Harvard Southern California Chronic Ozone Exposure Study: assessing ozone exposure of grade-school-age children in two Southern California communities.

The Harvard Southern California Chronic Ozone Exposure Study measured personal exposure to, and indoor and outdoor ozone concentrations of, approximately 200 elementary school children 6-12 years of age for 12 months (June 1995-May 1996). We selected two Southern California communities, Upland and several towns located in the San Bernardino mountains, because certain characteristics of those communities were believed to affect personal exposures. On 6 consecutive days during each study month, participant homes were monitored for indoor and outdoor ozone concentrations, and participating children wore a small passive ozone sampler to measure personal exposure. During each sampling period, the children recorded time-location-activity information in a diary. Ambient ozone concentration data were obtained from air quality monitoring stations in the study areas. We present ozone concentration data for the ozone season (June-September 1995 and May 1996) and the nonozone season (October 1995-April 1996). During the ozone season, outdoor and indoor concentrations and personal exposure averaged 48.2, 11.8, and 18.8 ppb in Upland and 60.1, 21.4, and 25.4 ppb in the mountain towns, respectively. During the nonozone season, outdoor and indoor concentrations and personal exposure averaged 21.1, 3.2, and 6.2 ppb in Upland, and 35.7, 2.8, and 5.7 ppb in the mountain towns, respectively. Personal exposure differed by community and sex, but not by age group.

Age Distribution↗

Use of health information systems in the Russian federation in the assessment of environmental health effects.

The Russian Federation has made an intensive effort to compile and use information on the environment and human health. In 1996-1997, we evaluated the information that was collected and analyzed on the local (raion), regional (oblast), and federal levels with reference to its usefulness in the assessment of environmental health effects. The Russian Federation maintains standardized nationwide institutions that routinely collect health data in polyclinics and hospitals and then report to the national offices. The allocations of the workforce and the broad range of surveyed health outcomes are extensive, but a lack of systematic control of information quality limits the ability to take full advantage of these efforts. On the other hand, the hierarchical system of data collection has advantages over more decentralized or commercial health systems. A major weakness in the current reporting is the aggregation and transformation of data. Although this may not disturb the generation of health statistics, it seriously limits the use of regional and federal level data in the assessment of health effects of environmental exposures. In spite of limitations, some revised approaches to the analysis of existing data may be both feasible and fruitful. Combining information from routine data and newly collected data is likely to be the most effective way to assess the relationship between environmental exposures and diseases. Although there is a strong and justifiable desire to rapidly translate information of environmental health effects into policy alternatives, at present, it seems more useful to emphasize data quality, completeness, and plans for the use of data.

Data Collection↗

Criteria air pollutants and toxic air pollutants.

This review presents a brief overview of the health effects and exposures of two criteria pollutants--ozone and particulate matter--and two toxic air pollutants--benzene and formaldehyde. These pollutants were selected from the six criteria pollutants and from the 189 toxic air pollutants on the basis of their prevalence in the United States, their physicochemical behavior, and the magnitude of their potential health threat. The health effects data included in this review primarily include results from epidemiologic studies; however, some findings from animal studies are also discussed when no other information is available. Health effects findings for each pollutant are related in this review to corresponding information about outdoor, indoor, and personal exposures and pollutant sources.

Air Pollutants↗

Particle concentrations in urban microenvironments.

Although ambient particulate matter has been associated with a range of health outcomes, the health risks for individuals depend in part on their daily activities. Information about particle mass concentrations and size distributions in indoor and outdoor microenvironments can help identify high-risk individuals and the significant contributors to personal exposure. To address these issues in an urban setting, we measured particle count concentrations in four size ranges and particulate matter (3/4) 10 microm (PM(10)) concentrations outdoors and in seven indoor microenvironments in Boston, Massachusetts. Particle counts and PM(10) concentrations were continuously measured with two light-scattering devices. Because of the autocorrelation between sequential measurements, we used linear mixed effects models with an AR-1 autoregressive correlation structure to evaluate whether differences between microenvironments were statistically significant. In general, larger particles were elevated in the vicinity of significant human activity, and smaller particles were elevated in the vicinity of combustion sources, with indoor PM(10) concentrations significantly higher than the outdoors on buses and trolleys. Statistical models demonstrated significant variability among some indoor microenvironments, with greater variability for smaller particles. These findings imply that personal exposures can depend on activity patterns and that microenvironmental concentration information can improve the accuracy of personal exposure estimation.

Air Pollutants↗

Ozone decay rates in residences.

In urban and suburban settings, indoor ozone exposures can represent a significant fraction of an individual's total exposure. The decay rate, one of the factors determining indoor ozone concentrations, is inadequately understood in residences. Decay rates were calculated by introducing outdoor air containing 80-160 parts per billion ozone into 43 residences and monitoring the reduction in indoor concentration as a function of time. The mean decay rate measured in the living rooms of 43 Southern California homes was 2.80 +/- 1.30 hr-1, with an average ozone deposition velocity of 0.049 +/- 0.017 cm/sec. The experimental protocol was evaluated for precision by repeating measurements in one residence on five different days, collecting 44 same-day replicate measurements, and by simultaneous measurements at two locations in six homes. Measured decay rates were significantly correlated with house type and the number of bedrooms. The observed decay rates were higher in multiple-family homes and homes with fewer than three bedrooms. Homes with higher surface-area-to-volume ratios had higher decay rates. The ratio of indoor-to-outdoor ozone concentrations in homes not using air conditioning and open windows was 68 +/- 18%, while the ratio of indoor-to-outdoor ozone was less than 10% for the homes with air conditioning in use.

Air Pollution, Indoor↗

Buildings operations and ETS exposure.

Mechanical systems are used in buildings to provide conditioned air, dissipate thermal loads, dilute contaminants, and maintain pressure differences. The characteristics of these systems and their operations h implications for the exposures of workers to environmental tobacco smoke (ETS) and for the control of these exposures. This review describes the general features of building ventilation systems and the efficacy of ventilation for controlling contaminant concentrations. Ventilation can reduce the concentration of ETS through dilution, but central heating, ventilating, and air conditioning (HVAC) can also move air throughout a building that has been contaminated by ETS. An understanding of HVAC systems is needed to develop models for exposures of workers to ETS.

Air Conditioning↗

Impact of residential nitrogen dioxide exposure on personal exposure: an international study.

Nitrogen dioxide (NO2) concentrations were measured during two-day winter periods in indoor and outdoor environments, and these concentrations were compared with simultaneously measured personal exposures in 18 cities in 15 countries around the world. Information was also gathered on activity patterns and household characteristics in order to determine the influences of these factors on personal exposures. All NO2 measurements were taken using passive filter badges. Personal exposures were found to vary greatly among the array of cities, with mean concentrations ranging between 11.0 ppb and 51.5 ppb. Personal NO2 exposures were more strongly correlated with indoor concentrations (r = 0.75) than with outdoor concentrations (r = 0.57) when all countries were considered simultaneously. Use of a gas stove in the home was the dominant activity influencing NO2 concentrations, with a 67% increase in mean personal NO2 exposure and an increase in indoor-outdoor ratios from 0.7 to 1.2 for participants using gas stoves, although preliminary evidence indicates the importance of combustion space heaters as well. These associations indicate the global nature of the correlation between personal NO2 exposures and indoor NO2 sources such as gas stoves or space heaters, demonstrating that this relationship is not dependent on country-specific parameters.

Air Pollution, Indoor↗

The Boston residential nitrogen dioxide characterization study: classification and prediction of indoor NO2 exposure.

Many epidemiological studies have used house characteristics associated with indoor sources as simplified proxies for personal nitrogen dioxide (NO2) exposure. Stove type and presence of a pilot light often been used as the two key characteristics, but significant overlaps have remained in the NO2 concentrations in the exposed and unexposed groups. This has contributed to inconsistencies in epidemiological findings, due to potential misclassification of exposure. In this study, other possible proxies were analyzed by cross-table analyses and were investigated in terms of improvements in both classification and predictive power. Adding building type to the above two proxies resulted in 0-5% of households with concentrations overlapping the observed range for the opposing stratum, compared with 22-42% for the two-proxy model. In spite of this performance, the predictive power of regression models for indoor NO2 was not improved by the addition of the third proxy, and the potential sample population was significantly limited. Using these analytical methods to choose descriptive proxies and evaluate the tradeoffs in their implementation can help epidemiological studies improve their designs and therefore optimize the robustness of their conclusions.

Air Pollution, Indoor↗

Determinants of nitrogen dioxide concentrations in indoor ice skating rinks.

OBJECTIVES: The combination of poor ventilation and fuel-powered ice resurfacers has resulted in elevated nitrogen dioxide (NO2) concentrations in many indoor ice skating rinks. This study examined the factors influencing concentrations and the effects of various engineering controls in ice rinks with different resurfacer fuels. METHODS: Indoor NO2 concentrations were measured in 19 enclosed ice skating rinks over 3 winters by means of passive samplers, with 1-week average measurements during the first winter pilot study and single-day working-hour measurements in the final 2 winters. Personal exposures to drivers also were assessed during the last winter. RESULTS: Rinks in which propane-fueled resurfacers were used had a daily mean indoor NO2 concentration of 206 ppb, compared with 132 ppb for gasoline-fueled and 37 ppb for electric-powered resurfacers. Engineering controls, such as increased ventilation and resurfacer tuning, reduced NO2 concentrations by 65% on average, but outcomes varied widely, and concentrations increased in subsequent months. CONCLUSIONS: Electric ice resurfacers, increased ventilation, or emission control systems are recommended to protect the health of workers and patrons, with surveillance programs proposed to track implementation and maintain an observer effect.

Air Pollutants, Occupational↗

[Determination of NO2 exposure--personal passive sampling versus indoor measurement].

Measurements of NO2 exposure of 29 inhabitants of Erfurt were carried out using personal passive samplers along with stationary passive samplers (indoor and outdoor) at the subjects' apartments and at their work places. The time adjusted results of the stationary measurements were compared with the results of the personal measurements and the differences (mean: 3, 15; max: +47; min: 14, 1 in ppb) were analysed. A multitude of recorded facts (e.g. use of gas stoves, smoking in the apartment) and factors which could not be quantified (e.g under- or over-estimation of the real impact of the pollutant on the person) results in disparities between the personal and stationary measured data. Though people spent 90% of the 48 hours measurement period indoors, time weighted stationary measurements of NO2 cannot replace personal measurements. For evaluation of health problems, lack of well being and work efficiency personal measurements are preferable.