PubMed HealthSearch

Biomedical subjects

J D Vega

Publications and source records attributed to J D Vega.

15 recordsLinked to original sources

Single-field total lymphoid irradiation in the treatment of refractory rejection after heart transplantation.

Nine heart transplant recipients were treated with single-field total lymphoid irradiation (TLI) for early (<1 year) or late (>1 year) rejection that was refractory to multiple regimens of immunosuppressive therapy. For patients with early rejection (n = 6), the rejection frequency (rejections/patient/month) decreased from pre-TLI of 1.63 to post-TLI of .02 (p < .001), and for patients with late rejection (n = 3), the rejection frequency decreased from pre-TLI of .23 to post-TLI of .05 (p < .02). The reduced rejection frequencies have been maintained for a mean follow-up of 28.6 (8 to 78) months, and adverse events during or late after TLI were uncommon. Single-field TLI is a safe and effective technique in the management of refractory rejection early or late after heart transplantation.

Adolescent

Reperfusion injury in single-lung transplant recipients with pulmonary hypertension and emphysema.

BACKGROUND: The early postoperative course of single-lung transplant recipients depends on the recipient's underlying lung pathophysiology and the degree of ischemic-reperfusion injury. We examined the effect of pulmonary hemodynamics and preoperative diagnosis on early allograft function and the effects of pulmonary hemodynamics, allograft blood flow, and chest radiographs on length of mechanical ventilation and intensive care unit length of stay. METHODS: We retrospectively collected data on 30 single-lung transplant recipients, 15 each with pretransplantation pulmonary hypertension and emphysema. Blood flow to the allografts was quantitated by perfusion scans obtained on the first postoperative day. Chest radiographs were graded for reperfusion injury. Pulmonary and hemodynamic data, gas exchange parameters, duration of mechanical ventilation, and intensive care unit stay were recorded. RESULTS: Patients with pulmonary hypertension had a prolonged intensive care unit stay compared with emphysema patients, but pulmonary artery pressures were not quantitatively related to duration of ventilation during the intensive care unit stay. There was no difference in the severity of allograft infiltrate between the emphysema and pulmonary hypertensive patients. The day 1 chest radiograph score was highly predictive of an intensive care unit stay of > or = 7 days, although the threshold score of those with pulmonary hypertension was significantly lower than in emphysema patients. Allograft blood flow and pulmonary hypertension were not contributors to early graft dysfunction. Allograft perfusion decreased with increasing radiographically demonstrated infiltrate in those with emphysema but not in those with pulmonary hypertension. CONCLUSIONS: Elevated allograft blood flow and pressures do not exacerbate radiographically confirmed reperfusion injury. Reperfusion injury is the major cause of early respiratory morbidity after single-lung transplantation. Allograft perfusion in emphysema patients decreases in response to reperfusion injury, but pulmonary hypertension patients remain almost entirely dependent on allograft function, even with severe chest radiograph scores. This may be an important mechanism by which single-lung transplant recipients with emphysema, unlike those with pulmonary hypertension, are able to mitigate the degree of respiratory impairment associated with reperfusion injury.

Blood Flow Velocity

Improved multiorgan function after prolonged univentricular support.

Eleven cardiac transplant candidates (all male; mean age, 43.3 years) with multiorgan (hepatic, pulmonary, and/or renal) dysfunction were sustained for prolonged periods (> 30 days) with the HeartMate (Thermo Cardiosystems, Inc, Woburn, MA) left ventricular assist device. We evaluated the effect of extended support on end-organ recovery and on the ultimate outcome of cardiac transplantation. In addition to cardiac failure, 9 patients had hepatic dysfunction, 8 had pulmonary dysfunction, and 6 had renal dysfunction (4 of whom required hemodialysis before left ventricular assist device support). Mean duration of support was 115 days (range, 31 to 233 days). All patients underwent successful transplantation; 10 of these patients survived a mean of 24 months. One patient, who had required hemodialysis and ventilatory support during and after support, experienced progressive multiorgan failure and died 7 weeks after transplantation. Two late deaths after transplantation were unrelated to the device. Overall, patients experienced improvement in cardiac functional class status, and most participated in cardiac rehabilitation programs before transplantation. During left ventricular assist device support, hepatic function returned to normal in 8 patients, pulmonary function recovered in 7, and renal function returned to normal in 4. One patient who required hemodialysis underwent renal transplantation after cardiac transplantation and had complete recovery of renal function. In the current era of donor shortages, gravely ill patients can benefit from a strategy of prolonged left ventricular assist device support. This strategy has proved safe, has allowed for reversal of multiorgan dysfunction, and has produced healthier transplant candidates.

Adult

Heart transplantation in Jehovah's Witnesses. An initial experience and follow-up.

More than 25 years of experience performing heart surgery on Jehovah's Witnesses has culminated in successful cardiac transplantation without administering blood products in five patients (mean age, 44.4 +/- 8.3 years) of this faith. The use of blood-conserving methods, iron supplementation, bone marrow-sparing maintenance immunotherapy, and brisk postoperative diuresis has added to the efficacy of cardiac transplantation in these patients. No perioperative deaths occurred, and early follow-up studies have shown that these patients have not been more susceptible to higher graft rejection rates due to the lack of pretransplant blood transfusions. As more Jehovah's Witnesses undergo heart transplantation in the future, comparison with other recipients who allow pretransplant blood transfusions may lead to a better understanding of rejection immunobiology. We conclude that cardiac transplants may be safely offered to Jehovah's Witnesses without fear of a uniformly poor outcome.

Adult

Rapid placement of the Hemopump and hemofiltration cannula.

Hypervolemia, a potential complication in patients on ventricular assist device support, can be managed by use of continuous arteriovenous hemofiltration. The Hemopump, a new catheter-mounted, transaortic axial-flow ventricular assist device, and the vascular access catheter for the Diafilter-30 Hemofilter system, used in continuous arteriovenous hemofiltration, are both usually inserted by way of the femoral artery. Because placing two large catheters in the femoral artery of a patient with peripheral vascular disease can compromise circulation, a technique for placing them in the abdominal aorta was developed. Two patients have undergone combined Hemopump and hemofiltration treatment, and neither experienced complications. Such techniques may benefit more patients in the future, as the usefulness of the Hemopump is proved.

Aorta, Abdominal

An outbreak of hantavirus pulmonary syndrome, Chile, 1997.

An outbreak of 25 cases of Andes virus-associated hantavirus pulmonary syndrome (HPS) was recognized in southern Chile from July 1997 through January 1998. In addition to the HPS patients, three persons with mild hantaviral disease and one person with asymptomatic acute infection were identified. Epidemiologic studies suggested person-to-person transmission in two of three family clusters. Ecologic studies showed very high densities of several species of sigmodontine rodents in the area.

Adult

Reevaluation of steroid tapering after steroid pulse therapy for heart rejection.

A retrospective analysis was conducted to determine the efficacy and complications resulting from steroid pulse therapy, with or without a steroid taper, in 93 episodes of heart transplant rejection that occurred in 72 patients (58 men, 14 women; mean age, 47.6 years). Each rejection episode was classified according to severity (Texas Heart Institute endomyocardial biopsy scale) and the treatment. Group 1 included 25 episodes of grade 7, 8, 9, or 10 rejection (International Society for Heart Transplantation [ISHT] grade IIIB or IV) that were treated with high-dose methylprednisolone (2.5 to 3.0 gm) and a steroid taper of 1.75 gm over 30 days. Group 2 included 16 episodes of rejection, with the severity of rejection and methylprednisolone pulse therapy being similar to that in group 1, but without a steroid taper. The results of treatment in group 1 were compared with those in group 2. Group 3 included 12 episodes of grade 5, 6, or 7 rejection (ISHT grade IIIA or IIIB) that were treated with moderate-dose methylprednisolone (1.0 to 2.0 gm) and a steroid taper, as described. Group 4 included 40 episodes of rejection, with the severity of rejection and methylprednisolone therapy being similar to that of group 3, but without a steroid taper. The results of treatment in group 3 were compared with those in group 4. No statistically significant differences were found among the groups regarding subsequent episodes of rejection or infection within 3 months of treatment. No statistically significant difference was noted among the groups in the number of rejection episodes requiring additional therapy to control the rejection.(ABSTRACT TRUNCATED AT 250 WORDS)

Female

Heart transplantation after mechanical circulatory support: four years' experience.

To determine the effect of mechanical circulatory support before heart transplantation, we conducted a retrospective analysis of 207 men who underwent staged orthotopic transplantations. Of these patients, 185 (group I) required pharmacologic support before transplantation; 14 (group II) required mechanical circulatory support with an intraaortic balloon pump (duration of support, 1 to 26 days); and eight (group III) required advanced mechanical circulatory support with an implantable left ventricular assist device (duration of support, 19 to 132 days). A comparison of complications after transplantation (infection and rejection), hospitalization, and survival showed that no significant differences existed among the three groups. In each group, respectively, 1-year survival was 80.9%, 77.3%, and 75%, and 2-year survival was 75.7%, 67.7%, and 75%. Based on our experience, patients receiving mechanical circulatory support before transplantation can be expected to have a good outcome. In fact, such support can help to improve their end-organ perfusion, and, thus, their status as heart transplantation candidates. Furthermore, this study shows that advanced mechanical circulatory support is possible even for prolonged periods, with low risk of sudden death. This finding is an important step toward development of a permanent assist device.

Adult

Successful bridge to heart transplantation with a new left ventricular assist device.

During the last 5 years, a new pneumatically driven left ventricular assist device has been implanted in 18 heart transplantation candidates who required advanced mechanical circulatory support. The mean duration of support was 80 +/- 74 days, and the cumulative support time was 1400 days. Fifteen patients were successfully supported until the time of heart transplantation. As a result of early experience, in which three of four patients died after heart transplantation because their end-organ function failed to recover, subsequent efforts were made to institute support early, before irreversible organ damage occurred. Eleven of the 12 patients in the later experience are currently alive and well at a mean follow-up of 12.6 +/- 7.5 months. No thromboembolic episodes occurred, and minimal anticoagulation was required. Furthermore, patients were able to participate in rehabilitative exercise programs, thus optimizing their transplantation status. Finally, the findings in these patients have shown the feasibility of providing long-term, or even permanent, cardiac assistance.

Adult

Adjuvant native heart surgery during heterotopic heart transplantation: two case reports.

The results of heterotopic heart transplantation may be further improved if repairs on native heart abnormalities are performed just before implantation of the allograft. Such procedures increase the potential for the recipient's own heart to recover function and, thus, to maintain circulation if the heterotopic heart malfunctions or fails. The native hearts of two of our patients, both women, showed signs of greater contractility and ejection after repair and were able to provide adequate circulatory support during periods of donor heart failure. The first patient required ventricular aneurysmectomy and coronary artery bypass grafting, and the second, native mitral valve repair. Moreover, when persistent ventricular fibrillation occurred in the donor heart of the first patient, a donor cardiectomy was performed, and the recipient heart functioned well thereafter. As more adjuvant operations are performed and the results evaluated, we may find that heterotopic operations would be suitable in a greater variety of heart transplant candidates.

Coronary Artery Bypass

Coronary artery bypass two years after orthotopic heart transplantation: a case report.

Complete occlusion of the left anterior descending and right coronary arteries developed in a 58-year-old man 2 years after orthotopic heart transplantation. Because of his progressive shortness of breath, reversible myocardial ischemia, and decreasing ejection fraction, aortocoronary bypass was recommended. The operation was performed without complications, and his postoperative ejection fraction improved by more than 58%. In the past, when coronary artery disease developed in cardiac allografts, another transplant procedure was the only treatment option. Because of the limited donor hearts available today, new strategies are necessary for the treatment of cardiac allograft atherosclerosis.

Coronary Artery Bypass

Nutritional assessment of patients with extended left ventricular assist device support.

The nutritional status of nine patients with end-stage heart disease who were supported by a left ventricular assist device (LVAD) for more than 30 days while awaiting cardiac transplantation was evaluated. Nutritional status was indicated by the following scale: 0-2, adequate nourishment; 3-5, moderate malnourishment; greater than 5, severe malnourishment. This scale was based on serial assessments of albumin, transferrin, total lymphocyte count, percentage of ideal body weight, midarm circumference, triceps skinfold, and arm muscle circumference. Each variable was compared with established standards before implantation and before transplantation times and assessed 1 point if less than the normal value and 0 points if within the normal range. At the time of LVAD implantation, 5 patients had a score of 0-2, 3 patients had a score of 3-5, and 1 patient had a score greater than 5. At the time of cardiac transplantation, 7 patients had a score of 0-2, 2 patients had a score of 3-5, and no patients had a score greater than 5. The patients who were able to meet at least 50% of their daily caloric and protein requirements by oral intake alone were noted. At LVAD implantation, only 2 patients (22%) met this requirement; however, 6 patients (67%) met this requirement at the time of cardiac transplantation. All 9 patients underwent cardiac transplantation, and 8 survived. Thus, it appears that extended LVAD support and maintenance of hemodynamic stability allow patients to regain the desire and ability to achieve adequate nutritional status, which may considerably reduce their perioperative transplant risks.

Anthropometry

Improved survival after Hemopump insertion in patients experiencing postcardiotomy cardiogenic shock during cardiopulmonary bypass.

Immediate placement of a Hemopump (HP) ventricular assist device was undertaken in nine patients (seven men, two women) after other attempts at weaning from cardiopulmonary bypass (CPB) after coronary bypass surgery had failed. All nine patients (100%) were successfully weaned from CPB, and six (63.3%) gradually improved enough to permit removal of HP support. Five (83.3%) of the six who were weaned from CPB survived beyond hospital discharge. HP support was evaluated in terms of vital organ function, incidence of complications, and clinical outcome. In both survivors (S) and nonsurvivors (NS), serial hemodynamic measurements were taken. Although there were few differences in hemodynamic parameters between groups at 4 hr, by 24 hr the S group had markedly improved cardiac index, Glasgow Coma Scale, urinary output, and pulse pressure and required far less inotropic support than did the NS group. All four patients who required high dose inotropic agents to maintain acceptable end-organ perfusion on HP support died; three were unable to tolerate weaning from the HP, and all died within 72 hr of surgery because of ineffective myocardial recovery. None of the survivors required additional early inotropic augmentation. Renal perfusion appeared to be well maintained, even with mean arterial pressures below 60 mmHg during HP support. There were no episodes of hemolysis, infection, or limb ischemia in either group. Thus, the Hemopump provided excellent circulatory support for those patients who could not be weaned from CPB by traditional methods.

Cardiopulmonary Bypass