PubMed Health⌕ Search

Biomedical subjects

J Danon

Publications and source records attributed to J Danon.

At least 19 recordsLinked to original sources

Nuclear spin effect in a metallic spin valve.

We study electronic transport through a ferromagnet normal-metal ferromagnet system and we investigate the effect of hyperfine interaction between electrons and nuclei in the normal-metal part. A switching of the magnetization directions of the ferromagnets causes nuclear spins to precess. We show that the effect of this precession on the current through the system is large enough to be observed in experiment.

Journal Article↗

Quantum tunneling detection of two-photon and two-electron processes.

We analyze the operation of a quantum tunneling detector coupled to a coherent conductor. We demonstrate that, in a certain energy range, the output of the detector is determined by two-photon processes, two-interacting-electron processes, and the interference of the two. We show how the individual contributions of these processes can be resolved in experiments.

Journal Article↗

Telithromycin (HMR 3647) achieves high and sustained concentrations in tonsils of patients undergoing tonsillectomy.

Telithromycin, the first ketolide antimicrobial to be developed for clinical use, has potent activity against group A beta-haemolytic streptococci (GABHS), including macrolide-resistant strains. The penetration of telithromycin into tonsils was assessed in 22 adults undergoing tonsillectomy at 3, 12 or 24 h after the fourth dose of oral telithromycin 800 mg once daily. Telithromycin rapidly penetrated tonsillar tissues, achieving a mean concentration of 3.95 mg/kg at 3 h post dose, 3.4 times greater than the corresponding plasma concentration (1.22 mg/l. The mean tonsil:plasma concentration ratio increased to 13.1 at 24 h post dose, indicating slower elimination from tonsils than plasma. Tonsillar and plasma concentrations exceeded the MIC(50) for GABHS throughout the 24-h dosing period. These findings suggest that telithromycin may be an effective new alternative treatment for GABHS tonsillopharyngitis.

Administration, Oral↗

[Therapeutic study of efficiency and tolerance of bacampicine used in oto-rhino-laryngology].

High dose Bacampicin given alone to 50 patients for obvious clinical manifestation of severe ENT infections proved most satisfactory, with rapid improvement in physical and general conditions. Samples from 21 patients showed presence of germs, all being sensitive to Bacampicin. No sign of intolerance was noted. It follows from this result that in cases with patent signs of severe ENT infections, 800 mg Bacampicin given along morning and evening provides an effective and well tolerated treatment.

Adult↗

Effects of lung volume and electrode position on the esophageal diaphragmatic EMG.

In anesthetized dogs studied both supine and prone, the electromyogram (EMG) of the diaphragm recorded directly from three portions of the diaphragm (crural, anterior, and costal) was compared with simultaneous recordings of the diaphragmatic EMG recorded from 10 sites in the esophagus and stomach. Effects upon the EMG of lung volume change and esophageal electrode position change were determined during bilateral supramaximal tetanic phrenic stimulation with airway occluded. Lung volume change had little effect upon the directly recorded EMG. The effect of lung volume change upon the EMG recorded from the esophagus was somewhat greater and marked change was noted as the esophageal recording site was varied. In supine dogs two sites of maximal signal were observed, one 1 cm above the cardia and the other 4--6 cm below the cardia. In prone dogs a single site for maximal signal was observed 3 cm above the cardia. An electrode site as close to the cardia as possible appears to be optimal from the point of view of variation in signal due to lung volume change and due to body position change. Gastric balloon stabilization is recommended. Proximity of the electrode and posterior gastric wall to the diaphragmatic crura may explain the maximal EMG signal recorded below the cardia.

Action Potentials↗

Thoracoabdominal motion in chronic obstructive pulmonary disease.

Studies of thoracoabdominal motion using the respiratory magnetometer were performed in 30 patients with chronic obstructive pulmonary disease. Volume equivalency of thoracic and abdominal deflections was established by using the concepts and methods developed by Konno and Mead. Twenty patients were ambulatory, although disabled, and 10 were in acute respiratory failure and were studied in a respiratory intensive care unit. Five of 20 ambulatory patients and 8 of 10 patients in acute respiratory failure showed inward abdominal motion coincident with outward rib cage motion during inspiration, suggesting ineffective diaphragmatic function. This pattern of thoracoabdominal motion was identical to that seen in 2 high quadriplegics with diaphragmatic paralysis when they were breathing entirely with their neck muscles. Inspiratory ascent of the diaphragm was confirmed fluoroscopically in 3 of the 5 ambulatory patients. Patients showing this pattern were generally severely disabled and had the largest residual volumes. Two abnormal patterns of thoracoabdominal motion were observed during the performance of maximal voluntary ventilation in the ambulatory patients. The first, seen in 9 of 20 patients, was characterized by reciprocal or paradoxical motion of rib cage and abdomen, with increase in rib cage volume associated with decrease in abdominal volume during inspiration. The second pattern, seen in 5 of 20 patients, showed complete disorganization of rib cage and abdominal motion, with no consistent or reproducible pattern. Thus, a significant proportion of patients with disabling chronic obstructive pulmonary disease show abnormalities in thoracoabdominal motion that are observable with the respiratory magnetometer and ofter by simple inspection. Most of these abnormalities suggest malfunction of respiratory muscles, particularly the diaphragm.

Abdomen↗

[Not Available].

Explore the source record for details and available documents.

Education, Medical↗

Mechanics of the canine diaphragm.

Diaphragmatic force-length behavior was assessed in anesthetized dogs using two techniques. One employed measurements in a diaphragm strip with intact nerve and blood supply; the second related transdiaphragmatic pressure (Pdi) to direct estimates of diaphragmatic tension from strain gauge arches during bilateral, tetanic, supramaximal phrenic nerve stimulation. In strip preparations the diaphragm exerted active force at lengths as short as 40% of resting in situ length (Lo), and maximal force was registered at a length averaging 25% greater than Lo. This suggested a broader effective length range for the diaphragm as compared to other skeletal muscles. In the intact preparation both Pdi and directly measured diaphragmatic tension were inversely related to lung volume and when they were used to calculate the diaphragm's effective radius of curvature (r), r was found to change little or decrease at large lung volumes rather than increase as theory would predict. These findings suggest that length tension characteristics outweigh geometric considerations in explaining the diaphragm's function in normal dogs and probably normal men.

Animals↗

[Not Available].

Explore the source record for details and available documents.

Education, Medical↗

[Not Available].

Explore the source record for details and available documents.

Education, Medical↗