PubMed Health⌕ Search

Biomedical subjects

J Debus

Publications and source records attributed to J Debus.

At least 91 records · Page 5Linked to original sources

Transfer of the human NaI symporter gene enhances iodide uptake in hepatoma cells.

UNLABELLED: The characteristic feature of thyroid cells of taking up iodide enables benign thyroid diseases and differentiated thyroid carcinoma to be successfully treated with radioiodide therapy. The transport of iodide across the cell membrane is mediated by the human NaI symporter (hNIS). We therefore investigated whether the accumulation of iodide may be induced by the retroviral transfer of the hNIS gene in nonthyroid tumor cells. METHODS: With use of a bicistronic retroviral vector for the transfer of the hNIS coding sequence and the hygromycin resistance gene, rat Morris hepatoma (MH3924A) cells were infected with retroviral particles and 32 hNIS-expressing cell lines were generated by hygromycin selection. After incubation of the genetically modified and wild-type hepatoma cells and the rat thyroid cell line FRTL5 with Na125I, the uptake and efflux of iodide were determined. In addition, the iodide distribution in rats bearing wild-type and genetically modified hepatomas was monitored. RESULTS: Genetically modified MH3924A cell lines accumulated up to 235 times more iodide than did noninfected hepatoma cells. The maximal iodide uptake in the cells was observed after 60 min incubation time. Competition experiments in the presence of sodium perchlorate revealed a dose-dependent decrease of iodide uptake (87%-92%). Moreover, carbonyl cyanide p-trifluoromethoxyphenylhydrazone led to a loss of accumulated I- (32%), whereas 4,4'-diisothiocyano-2,2'-disulfonic acid stilbene increased the I- uptake into the cells (22%). However, a rapid efflux of the radioactivity (80%) was observed during the first 10 min after 125I(-)-containing medium had been replaced by nonradioactive medium. In rats, the hNIS-expressing tumors accumulated six times more iodide than did the contralateral wild-type tumor as monitored by scintigraphy. The ex vivo quantitation of the iodide content performed 1 h after tracer administration in 1 g of tumor tissue revealed a 17-fold higher iodide accumulation in the genetically modified tumors. In accordance with the in vitro data, we also observed a rapid efflux of radioactivity from the tumor in vivo. CONCLUSION: The transduction of the hNIS gene per se is sufficient to induce 125I transport in Morris hepatoma cells in vitro and in vivo. With regard to a therapeutic application, however, additional conditions need to be defined that inhibit the iodide efflux from the tumor cells.

Animals↗

PET imaging of somatostatin receptors using [68GA]DOTA-D-Phe1-Tyr3-octreotide: first results in patients with meningiomas.

UNLABELLED: Imaging of somatostatin receptors (SSTRs) using [111In]diethylenetriaminepentaacetic-acid-octreotide (DTPAOC) has proven to be helpful in the differentiation of meningiomas, neurinomas or neurofibromas, and metastases as well as in the follow-up of meningiomas. A drawback of the SPECT method is its limited sensitivity in detecting small meningiomas. Because of PET's increased spatial resolution and its ability to absolutely quantify biodistribution, a PET tracer for SSTR imaging would be desirable. METHODS: 1,4,7,10-tetraazacyclododecane-N,N',N",N"'-tetraacetic-acid-D-Phe1-Tyr3-octreotide (DOTATOC) was labeled using the positron-emitting generator nuclide 68Ga. We acquired dynamic PET images over 120 min after intravenous injection of 175 MBq [68Ga]DOTATOC in 3 patients suffering from 8 meningiomas (WHO I degrees; 7- to 25-mm diameter). Patients' heads had been fixed using individually shaped fiber masks equipped with an external stereotactic localizer system to match PET, CT, and MRI datasets. RESULTS: [68Ga]DOTATOC was rapidly cleared from the blood (half-life alpha, 3.5 min; half-life beta, 63 min). Standardized uptake values (SUVs) of meningiomas increased immediately after injection and reached a plateau 60-120 min after injection (mean SUV, 10.6). No tracer could be found in the surrounding healthy brain tissue. All meningiomas (even the 3 smallest [7- to 8-mm diameter]) showed high tracer uptake and could be visualized clearly. Tracer boundaries showed a good correspondence with the matched CT and MRI images. PET provided valuable additional information regarding the extent of meningiomas located beneath osseous structures, especially at the base of the skull. CONCLUSION: According to our initial experiences, [68Ga]DOTATOC seems to be a very promising new PET tracer for imaging SSTRs even in small meningiomas, offering excellent imaging properties and a very high tumor-to-background ratio.

Gallium Radioisotopes↗

Proton MR spectroscopic evaluation of suspicious brain lesions after stereotactic radiotherapy.

BACKGROUND AND PURPOSE: The radiologic assessment of suspicious brain lesions after stereotactic radiotherapy of brain tumors is difficult. The purpose of our study was to define parameters from single-voxel proton MR spectroscopy that provide a probability measure for differentiating neoplastic from radiation-induced, nonneoplastic lesions. METHODS: Seventy-two lesions in 56 patients were examined using a combined MR imaging and MR spectroscopy protocol (point-resolved spectroscopy, TE = 135 ms). Signal intensities of cholines, creatines, N-acetyl aspartate, and the presence of lactate and lipid resonances were correlated to final diagnoses established by clinical and MR imaging follow-up, positron emission tomography studies, or biopsy/surgery. Statistical analysis was performed using the t test, linear discriminant analysis, and k nearest-neighbor method. RESULTS: Significantly increased signal intensity ratios I(tCho)/I(tCr) (P <.0001) and I(tCho)/I(NAA) (P <.0001) were observed in neoplastic (n = 34) compared with nonneoplastic lesions (n = 32) and contralateral normal brain (n = 33). Analysis of I(tCho)/I(tCr) and I(tCho)/I(NAA) data yielded correct retrospective classification as neoplastic and nonneoplastic in 82% and 81% of the lesions, respectively. Neither I(NAA)/I(tCr) nor signal intensitities of lactate or lipids were useful for differential diagnosis. CONCLUSION: Metabolic information provided by proton MR spectroscopy is useful for the differentiation of neoplastic and nonneoplastic brain lesions after stereotactic radiotherapy of brain tumors.

Adult↗

Comparison of intensity-modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors.

PURPOSE: Conformal and intensity-modulated radiotherapy (IMRT) plans for 9 patients were compared based on characterization of plan quality and effects on the oncology department. METHODS AND MATERIALS: These clinical cases, treated originally with conformal radiotherapy (CRT), required extraordinary effort to produce conformal treatment plans using nonmodulated, shaped noncoplanar fields with multileaf collimators (MLCs). IMRT plans created for comparison included rotational treatments with slit collimator, and fixed-field MLC treatments using equispaced coplanar, and noncoplanar fields. Plans were compared based upon target coverage, target conformality, dose homogeneity, monitor units (MU), user-interactive planning time, and treatment delivery time. The results were subjected to a statistical analysis. RESULTS: IMRT increased target coverage an average of 36% and conformality by 10%. Where dose escalation was a goal, IMRT increased mean dose by 4-6 Gy and target coverage by 19% with the same degree of conformality. Rotational IMRT was slightly superior to fixed-field IMRT. All IMRT techniques increased integral dose and target dose heterogeneity. IMRT planning times were significantly less, whereas MU increased significantly; estimated delivery times were similar. CONCLUSION: IMRT techniques increase dose and target coverage while continuing to spare organs-at-risk, and can be delivered in a time frame comparable to other sophisticated techniques.

Carcinoma, Adenoid Cystic↗

Conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas.

PURPOSE: Analysis of local tumor control and functional outcome following conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas. PATIENTS AND METHODS: From 11/1989 to 9/1999 51 patients with acoustic neuromas have been treated by FSRT. Mean total dose was 57.6 +/- 2.5 Gy. Forty-two patients have been followed for at least 12 months and were subject of an outcome analysis. Mean follow-up was 42 months. We analyzed local control, hearing preservation, and facial and trigeminal nerve functional preservation. We evaluated influences of tumor size, age, and association with neurofibromatosis Type 2 (NF2) on outcome and treatment related toxicity. RESULTS: Actuarial 2- and 5-year tumor control rates were 100% and 97.7%, respectively. Actuarial useful hearing preservation rate was 85% at 2 and 5 years. New hearing loss was diagnosed in 4 NF2 patients. Pretreatment normal facial nerve function was preserved in all cases. Two cases of new or impaired trigeminal nerve dysesthesia required medication. No other cranial nerve deficit was observed. In Patients without NF2 tumor size or age had no influence on tumor control and cranial nerve toxicity. Diagnosis of NF2 was associated with higher risk of hearing impairment (p = 0.0002), the hearing preservation rate in this subgroup was 60%. CONCLUSION: FSRT has been shown to be an effective means of local tumor control. Excellent hearing preservation rates and 5th and 7th nerve functional preservation rates were achieved. The results support the conclusion that FSRT can be recommended to patients with acoustic neuromas where special attention has to be taken to preserve useful hearing and normal cranial nerve function. For NF2 patients, FSRT may be the treatment of choice with superior functional outcome compared to treatment alternatives.

Actuarial Analysis↗

Conformal radiotherapy of challenging paraspinal tumors using a multiple arc segment technique.

PURPOSE: Target volumes that wrap around the spinal cord are difficult to treat. We present and evaluate a refined multiple arc segment (MAS) technique that is applicable with standard three-dimensional (3D) radiotherapy equipment and may be a solution for facilities that do not yet have full access to intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS: The presented technique consisted of 13 isocentric coplanar beam's eye view shaped fields, delivered as 20 degrees or 10 degrees arc segments with an integrated multileaf collimator (MLC) using automatic sequential field delivery. Dose-volume histograms (DVH) for this technique were compared to a modified bar-arc technique (MBA) modeled as 30 static fields and to an inverse planned IMRT technique using 7 coplanar, equispaced beams delivered with the same MLC. RESULTS: Compared to the MBA technique, maximum dose and target coverage were similar when using 80% of the maximum dose as the reference dose. However, the MAS technique reduced the maximum doses (to > or = 1% of the organs at risk [OAR]) by 9% for the spinal cord, 17% for the esophagus, and 25% for the trachea, as well as the mean doses. Although inverse planned IMRT could further reduce exposure of OAR except for the spinal cord and improve target coverage, our forward planned MAS technique seems to achieve clinically comparable results. CONCLUSION: Substituting a series of small split-field arc segments for large static fields and using additional narrow paraspinal segments significantly improves the sparing of organs at risk for paraspinal targets. Although these results are not quite as good as those achieved with IMRT, for facilities not yet equipped with inverse treatment planning capability, the presented technique enables dose escalation for primary paraspinal tumors and retreatment of recurrent lesions.

Esophagus↗

Radiation-induced regional cerebral blood volume (rCBV) changes in normal brain and low-grade astrocytomas: quantification and time and dose-dependent occurrence.

PURPOSE: New tumor-conformal radiation-treatment modalities have been established with the intention to spare normal tissue while maintaining or improving local tumor control. To document radiation-induced changes in normal brain and low-grade astrocytoma we measured regional cerebral blood volumes (rCBV) using a dynamic susceptibility-weighted contrast-enhanced MR technique (DSC-MRI). We attempted to assess pretherapeutic rCBV values and time- and dose-dependent changes following radiotherapy. METHODS AND MATERIALS: For prospective and longitudinal assessment of rCBV in normal brain and low-grade astrocytoma, 25 patients with histologically proven fibrillary astrocytoma (WHO Grade II) were examined before radiotherapy and during follow-up. Based on CT- and MR-data sets in a stereotactic setup, three-dimensional (3D) treatment planning was done. Radiotherapy was delivered using fractionated stereotactic radiotherapy (FSRT) to mean and median total doses of 60.9 and 60 Gy, respectively (range, 55.8-66 Gy). During MR imaging for treatment planning and follow-up examinations, 55 T2-weighted gradient echo images were acquired before, during, and after intravenous contrast bolus injection. The acquired signal-time curves were converted into concentration-time curves. The area under the tissue concentration-time curve was calculated and normalized to an integrated arterial input function. Thus, absolute rCBV values could be calculated. RESULTS: Pretherapeutic mean rCBV for normal gray (GM) and white brain matter (WM) were 7.2 +/- 2.7 and 3.6 +/- 1.5 mL/100 g tissue, respectively. Mean rCBV for astrocytoma was 6.5 +/- 3.7 mL/100 g tissue. After radiotherapy, rCBV for GM and WM was significantly reduced (p < 0.01) in high-dose areas (40-100% of total dose). A nonsignificant reduction was measured in low-dose areas (up to 40% of total dose). Reduction of rCBV in astrocytomas to a plateau level of 4.6 +/- 0.4 mL/100 g tissue was measured at 6 months after radiotherapy and remained stable in locally controlled tumors. CONCLUSION: Monitoring of rCBV changes in normal brain and low-grade astrocytoma was feasible using a DSC-MRI technique. The method was able to document radiation effects in low-grade astrocytoma, even if the majority of tumors showed no change in diagnostic MR-imaging. Radiation induced decrease of rCBV in GM and WM was correlated to total dose delivered to a tissue area, with high doses causing a significant decrease. Minor decline of rCBV in GM and WM outside high-dose areas after stereotactic radiotherapy confirms the efficacy to spare normal brain tissue by the use of modern conformal radiotherapy techniques. Nonetheless, a critical minimal dose initiating rCBV changes is yet unknown.

Adult↗

Stereotactic fractionated radiotherapy for chordomas and chondrosarcomas of the skull base.

PURPOSE: To investigate the treatment outcome of patients suffering from skull base chordoma or chondrosarcoma after fractionated stereotactic radiotherapy. METHODS AND MATERIALS: We report 45 patients treated for chordoma or chondrosarcoma with postoperative fractionated stereotactic radiotherapy between 1990 and 1997. Patients had CT and MRI for 3D treatment planning performed under stereotactic guidance. Median dose at isocenter was 66.6 Gy for chordomas and 64.9 Gy for chondrosarcomas. MRI imaging was obtained in intervals after therapy to evaluate local relapse. Survival was calculated according to the Kaplan-Meier method. RESULTS: All chondrosarcomas had achieved and maintained local control and recurrence-free status at follow-up of 5 years. Local control rate of chordomas was 82% at 2 years and 50% at 5 years. Survival was 97% at 2 years and 82% at 5 years. At maximum follow-up of 8 years local control and survival rate of chordomas was 40% (82%). Clinically significant late toxicity developed in one patient. CONCLUSIONS: Our results demonstrate the feasibility of fractionated photon beam therapy and its success in the treatment of skull base tumors. Modern 3D treatment techniques provide superior results compared to conventional techniques. The role of high-precision radiotherapy compared to particle beam therapy in the treatment of these tumors is not yet fully clear and further research is needed.

Adolescent↗

Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases.

PURPOSE: Patients with liver metastases might benefit from high-dose conformal radiation therapy. A high accuracy of repositioning and a reduction of target movement are necessary for such an approach. The set-up accuracy of patients with liver metastases treated with stereotactic single dose radiation was evaluated. METHODS AND MATERIALS: Twenty-four patients with liver metastases were treated with single dose radiation therapy on 26 occasions using a self-developed stereotactic frame. Liver movement was reduced by abdominal pressure. The effectiveness was evaluated under fluoroscopy. CT scans were performed on the planning day and directly before treatment. Representative reference marks were chosen and the coordinates were calculated. In addition, the target displacement was quantitatively evaluated after treatment. RESULTS: Diaphragmal movement was reduced to median 7 mm (range: 3-13 mm). The final set-up accuracy of the body was limited to all of median 1.8 mm in latero-lateral direction (range: 0.3-5.0 mm) and 2.0 mm in anterior-posterior direction (0.8-3.8 mm). Deviations of the body in cranio-caudal direction were always less than the thickness of one CT slice (<5 mm). However, a repositioning was necessary in 16 occasions. The final target shift was median 1.6 mm (0.2-7.0 mm) in latero-lateral and 2.3 mm in anterior-posterior direction (0.0-6.3 mm). The median shift in cranio-caudal direction was 4.4 mm (0.0-10.0 mm). CONCLUSIONS: In patients with liver metastases, a high set-up accuracy of the body and the target can be achieved. This allows a high-dose focal radiotherapy of these lesions. However, a control CT scan should be performed directly before therapy to confirm set-up accuracy and possibly prompt necessary corrections.

Aged↗

Assessment of cerebral gliomas by a new dark fluid sequence, high intensity REduction (HIRE): a preliminary study.

The purpose of this study was to assess the diagnostic potential of a new dark fluid sequence, high intensity reduction (HIRE) in the diagnostic workup of patients with cerebral gliomas. The HIRE sequence utilizes a very long T(2) value of the cerebrospinal fluid (CSF) to suppress its high signal contribution in T(2)-weighted imaging by a image subtraction technique. Fifteen patients with histologically confirmed cerebral gliomas were examined with T(2)-weighted fast spin-echo (FSE), T(1)-weighted SE, fast fluid-attenuated inversion recovery (FLAIR), and HIRE imaging using identical scan parameters. In patients with enhancing lesions, fast FLAIR and HIRE were added to the contrast-enhanced T(1)-weighted SE images. Images were analyzed in a qualitative and quantitative evaluation. In the qualitative analysis, lesion detection, lesion delineation, and differentiation between enhancing and non-enhancing tumor tissue were assessed in a two-reader study. For the quantitative analysis, lesion-to-background and lesion-to-CSF contrast and contrast-to-noise ratios were determined in a region of interest analysis. HIRE achieved a significant reduction of the CSF signal without losing the high gray-to-white matter contrast of T(2)-weighted sequences. In the quantitative analysis, the contrast ratios of the HIRE images were lower compared with the FLAIR images due to a relatively high background and CSF signal. After administration of contrast media, HIRE images presented a significant signal increase in enhancing lesions, which subsequently increased the contrast and contrast-to-noise ratios. In the qualitative analysis, both readers found all tumors clearly delineated on HIRE imaging. Compared with T(2)-weighted FSE, the tumor delineation with HIRE was better in nine patients, equal in four patients, and less in one patient. Compared with the FLAIR images, HIRE was rated superior in three patients, equal in nine patients, and inferior in another three patients. Delineation of the enhancing tumor parts was possible with HIRE in all patients. HIRE images had significantly fewer image artifacts than FLAIR images due to reduced inflow effects. The T(2)-based HIRE sequence presented is an alternative to the T(1)-based FLAIR sequence, with the advantage of better gray-to-white matter contrast and shorter measurement time. Due to the subtraction technique, signal intensities from tissues with relaxation times in the range T(2 WM) < < T(2) < T(2 CSF) are also gradually affected, corresponding to their T(2) values. With respect to this unwanted effect, an improvement in HIRE imaging will be possible by using a self-weighted subtraction algorithm. In a forthcoming study this concept will first be tested on appropriate phantom fluids.

Adult↗

[Improved tumor contrast and delineation in the stereotactic radiotherapy planning of cerebral gliomas and metastases with contrast media-supported FLAIR imaging].

BACKGROUND: FLAIR MR imaging has shown to be a valuable imaging modality in pathologic lesions of the brain including intra-axial brain tumors. The aim of the study was to assess the value of a FLAIR technique in the planning process of stereotactic radiotherapy in patients with cerebral gliomas and metastases. PATIENTS AND METHODS: Thirty-five patients with cerebral gliomas and 12 patients with a total of 39 cerebral metastases were examined by T2/PD-weighted fast spin-echo, fast FLAIR prior and after contrast and contrast enhanced T1-weighted spin-echo using identical slice parameters. The images were evaluated by using quantitative and qualitative criteria. Quantitative criteria were tumor-to-background and tumor-to-cerebrospinal fluid contrast and contrast-to-noise. The qualitative evaluation was performed as a multireader analysis concerning lesion detection, lesion delineation and image artifacts. RESULTS: In the qualitative evaluation (Table 3 and 6), all readers found the fast FLAIR images to be superior to fast spin-echo in the exact delineation of cerebral tumors (p < 0.001) and the delineation of enhancing and non enhancing tumor parts. Fast FLAIR was superior in the delineation of cortically located and small lesions but was limited in lesions adjacent to the ventricles. Fast FLAIR provided a significantly better tumor-to-CSF contrast and tumor-to-CSF contrast-to-noise (p < 0.001) (Tables 1, 2a, 2b, 4, 5). The tumor-to-background contrast and tumor-to-background contrast-to-noise of the fast FLAIR images were lower than that of T2-weighted spin-echo images but were significantly increased after the application of contrast media. FLAIR images had more image artifacts, but the image interpretation was not influenced. CONCLUSIONS: FLAIR MR imaging was found to be a valuable sequence in the planning protocol of stereotactic radiotherapy. The concurrent presentation of enhancing and non enhancing tumor tissue on contrast enhanced fast FLAIR imaging enables to use a single imaging sequence in the treatment protocol. This enables to load a reduced image amount into the radiotherapy planning software, is therefore time saving and reduces potential errors.

Adolescent↗

[Carbon ion irradiation of skull base tumors at GSI. First clinical results and future perspectives].

BACKGROUND: Radiobiological and physical examinations suggest clinical advantages of heavy ion irradiation. We report the results of 23 women and 22 men (median age 48 years) with skull base tumors irradiated with carbon ion beams at the Gesellschaft für Schwerionenforschung (GSI), Darmstadt, from December 1997 until September 1999. PATIENTS AND METHODS: The study included patients with chordomas (17), chondrosarcomas (10) and other skull base tumors (Table 1). It is the first time that the intensity-controlled rasterscan-technique and the application of positron-emission tomography (PET) for quality assurance was used. All patients had computed tomography for three-dimensional-treatment planning (Figure 1). Patients with chordomas and chondrosarcomas underwent fractionated carbon ion irradiation in 20 consecutive days (median total dose 60 GyE). Other histologies were treated with a carbon ion boost of 15 to 18 GyE delivered to the macroscopic tumor after fractionated stereotactic radiotherapy (median total dose 63 GyE). RESULTS: Mean follow-up was 9 months. Irradiation was well tolerated by all patients. Partial tumor remission was seen in 7 patients (15.5%) (Figure 2). One-year local control rate was 94%. One patient (2.2%) deceased. No severe toxicity and no local recurrence within the treated volume were observed. CONCLUSION: Clinical effectiveness and technical feasibility of this therapy modality could clearly be demonstrated in our study. To evaluate the clinical relevance of the different beam modalities studies with larger patient numbers are necessary. To continue our project a new heavy ion accelerator exclusively for clinical use is planned to be constructed in Heidelberg.

Adolescent↗

[First experiences with a noninvasive patient set-up system for radiotherapy of the prostate].

PURPOSE: Highly conformal radiotherapy techniques require precise patient positioning. We report our first experience with a new cast system for fixation of the pelvis during stereotactically guided intensity modulated radiotherapy (IMRT) of the prostate with respect to positioning accuracy of the prostate. MATERIAL AND METHODS: The immobilization device consists of a custom-made wrap-around body cast that extends from the abdomen to the thighs and a separate head mask, both made from Scotchcast, and attaches to a frame for extracranial stereotaxy. Sixteen CT-studies (> or = 25 slices, thickness: 3 mm) of 2 patients who were immobilized for IMRT of prostate tumors were evaluated with respect to set-up accuracy of bony structures and the prostate itself. CT-studies were performed immediately before or after a treatment fraction. Deviations of bony landmarks and anatomical landmarks inside the planning target volume were measured in all 3 dimensions. RESULTS: Mean patient movements of 0.15 +/- 0.3 mm (latero-lateral), 0.9 +/- 1 mm (anterior-posterior), 1 +/- 1 mm (tranversal vectorial error) and < 3 mm slice thickness (craniocaudal) were recorded using bony landmarks and 0.9 +/- 0.9 mm (latero-lateral), 1.8 +/- 1.5 mm (anterior-posterior), 2.2 +/- 1.5 mm (transversal vectorial error) and < 3 mm (craniocaudal) using the confines of, or landmarks within the prostate. Standard deviations of absolute positioning error as an often used metric for positioning accuracy ranged between 0.3 and 1.7 mm in the transversal plane. The worst case transversal vectorial deviation for the prostate was 4.4 mm. Figure 4 summarizes the set-up accuracy of bony landmarks and the prostate. CONCLUSION: The presented combination of a body cast and head mask system in a rigid stereotactic body frame ensures reliable noninvasive patient fixation for fractionated extracranial stereotactic radiotherapy. It provides precise and reliable positioning of the prostate and meets the requirements for highly conformal radiotherapy such as IMRT. No further improvement of repositioning can be achieved with external immobilization devices since the positioning error of the target relative to the skeleton exceeds the accuracy of the positioning of the skeleton itself.

Humans↗

[HIRE (high intensity reduction). New cerebrospinal fluid suppressed T2-weighted imaging sequence].

PURPOSE: The HIRE sequence utilizes the very long T2 value of CSF to suppress its high signal contribution in T2-weighted imaging by an image subtraction technique. METHODS: To assess the diagnostic potential of a new dark fluid sequence HIRE (High Intensity REduction) in the diagnostic work-up, 20 patients with histologically confirmed cerebral gliomas were examined with T2-weighted FSE, T1-weighted SE, fast FLAIR and HIRE using identical scan parameters. In patients with enhancing lesions fast FLAIR and HIRE were added to the contrast-enhanced T1-weighted SE images. Images were analyzed in a qualitative and quantitative evaluation. In the qualitative lesion analysis, lesion delineation and differentiation between enhancing and non enhancing tumor tissue were by two readers. For the quantitative analysis lesion-to-background and lesion-to-CSF contrast and contrast to noise ratios were determined in an region of interest analysis. RESULTS: HIRE achieved a significant reduction of the CSF signal without loosing the high gray-to-white matter contrast of T2 weighted sequences. In the quantitative analysis, the contrast ratios of the HIRE were lower compared to the FLAIR images due to a relative high background and CSF signal. After the application of contrast media HIRE images revealed a significant signal increase in enhancing lesions, which subsequently increased the contrast and contrast-to-noise ratios. In the qualitative analysis, both readers found all tumors clearly delineated on HIRE imaging. Compared to T2-weighted FSE the tumor delineation with HIRE was better in nine patients, equal in four patients and less in one patient. Compared to the FLAIR images HIRE was rated superior in three patients, equal in nine patients and inferior in another three patients. Delineation of the enhancing tumor parts was possible with HIRE in all patients. HIRE images present significant less image artifacts than FLAIR images due to reduced inflow effects. CONCLUSIONS: The presented T2 based HIRE sequence is an alternative to the T1 based FLAIR sequence with the advantage of a better gray to white matter contrast and shorter measurement time. Due to the subtraction technique signal intensities from tissues with T2 relaxation times in the range between white matter and CSF are also partially affected depending on their T2 values. With respect to this undesired effect, an improvement in HIRE imaging will be expected by a self-weighted subtraction algorithm.

Artifacts↗

Stereotactic radiation therapy for malignant choroidal tumors: preliminary, short-term results.

PURPOSE: To evaluate the role of stereotactic radiation therapy (SRT) in the treatment of malignant choroidal tumors. DESIGN: Prospective, noncomparative case series. PARTICIPANTS: Ten patients with unifocal choroidal metastasis (three lung carcinoma, three breast carcinoma, three colon carcinoma, one cutaneous melanoma) and five patients with primary choroidal melanoma underwent single-dose or fractionated SRT. METHODS: Before treatment, computed tomography (CT) scans of the orbit were obtained with the patient wearing an individualized immobilization mask. An integrated macro-CCD-camera system viewed the eye for detection of movements. Three-dimensional computer-based treatment planning was carried out. Dose distribution was calculated and displayed in isodose lines on the CT data set. For SRT, a dedicated stereotactic linear accelerator (6 MV) was used. Total doses for choroidal metastases were 12 to 20 Gy in a single dose or 30 Gy over 10 days (3 Gy each session), and total doses for choroidal melanoma were 50 Gy over 5 or 10 days (10 or 5 Gy each session). MAIN OUTCOME MEASURES: Best corrected visual acuity (ETDRS-chart), biomicroscopy, ultrasound examination, fluorescein angiography, and magnetic resonance imaging (MRI) were performed before treatment and at regular intervals after completion of SRT. RESULTS: During a follow-up period from 1 to 34 months (median, 6.5 months), local tumor control was achieved in all eyes. A decrease in tumor size on ultrasonography or MRI was noted in eight patients. No persistent side effects were observed during follow-up. CONCLUSIONS: Stereotactic radiation therapy allows steep dose gradients outside the target volume by minimizing the field of exposure. Thus only low radiation doses affect surrounding radiosensitive ocular structures. Our initial findings suggest that this technique may be effective in controlling tumor growth. Further studies are needed to compare treatment efficacy and safety with conventional treatment methods.

Adult↗

Conformal three-dimensional photon radiotherapy for paranasal sinus tumors.

BACKGROUND: Tumors in the nasal cavity and paranasal sinus are difficult to treat with radiotherapy. Usually, in addition to a two- or three-field photon technique, an interorbital electron field is required. This may result, however, in severe over- or underdosage, the latter being especially detrimental when occurring in the main tumor bulk. METHODS AND RESULTS: We present a conformal three-dimensional treatment technique that provides sufficient interorbital dose with photons only while sparing the eyes, optic nerves and chiasm, and may be considered for selected tumors in this region.

Dose-Response Relationship, Radiation↗

Fractionated stereotactic conformal radiation therapy of brain stem gliomas: outcome and prognostic factors.

BACKGROUND AND PURPOSE: Evaluation of outcome and prognostic factors in patients with brain stem glioma (BSG) following fractionated stereotactic radiotherapy (FSRT). MATERIALS AND METHODS: Between 1990 and 1997, we treated 41 patients with FSRT in a phase I/II trial. Median age was 24 years. Out of 36 patients with histologically proven glioma, ten had a partial tumour resection. Histology revealed low grade gliomas in 30 patients and anaplastic gliomas in six patients. A mean total dose of 54 Gy was given in daily fractions of 1.8 Gy. Median follow-up was 12 months. RESULTS: Three patients died during FSRT. Neurological improvement was achieved in 19/38 patients. Reduction of tumour size was reported in 12/38, in 16 patients the lesion was unchanged, ten showed progression. Median time to progression was 23 months, median overall survival 40 months with an actuarial survival of 83% at 1 year, 55% at 3 years and 33% at 5 years. In 20 of 22 patients with recurrence progression was inside the target volume. Significant prognostic factors for survival were clinical and radiological response 6 weeks after FSRT. Treatment toxicity was mild. Ototoxicity occurred in one patient. CONCLUSIONS: FSRT is a feasible treatment modality for BSG with tolerable toxicity. The risk of marginal failure is low.

Adolescent↗

Disappearance of tumor contrast on contrast-enhanced FLAIR imaging of cerebral gliomas.

Contrast-enhanced fluid-attentuated inversion recovery (FLAIR) magnetic resonance (MR) imaging has shown to be a valuable diagnostic modality in the assessment of cerebral gliomas. In this study we report of a potential pitfall regarding the delineation of enhancing tumor parts on contrast enhanced FLAIR imaging. In a limited number of patients, the administration of gadolinium obscures the area of contrast enhancement on contrast enhanced FLAIR images. Therefore the delineation of the macroscopic tumor parts, which are of great importance for the treatment planning is substantially worsened.

Adult↗