PubMed Health⌕ Search

Biomedical subjects

J Diaper

Publications and source records attributed to J Diaper.

4 recordsLinked to original sources

Continuous haemodynamic monitoring using transoesophageal Doppler during acute normovolaemic haemodilution in patients with coronary artery disease.

Transoesophageal Doppler monitoring allows non-invasive assessment of stroke volume. We studied haemodynamic changes during acute normovolemic haemodilution (ANH) in anaesthetised patients with coronary artery disease. Twenty patients were randomly assigned to either ANH or a control group. During ANH, a mean (SD) blood volume of 15.3 (3.4) ml.kg(-1) was withdrawn decreasing systemic oxygen delivery from 12.7 (3.3) to 9.3 (1.8) ml.kg(-1).min(-1) (p < 0.001). In the control group, haemodynamic data remained unchanged, whereas in the ANH group, stroke volume and central venous pressure increased significantly (mean = +21 ml [95% CI: 18-25 ml.min(-1)]; mean = +2.5 mmHg [95% CI: 2.2-2.8 mmHg], respectively) and heart rate decreased (mean = -6 beat.min(-1)[95% CI: 6-8 beat.min(-1)], p < 0.05). According to the Frank-Starling relationship, individual changes in stroke volume compared with central venous pressure fitted a quadratic regression model (R2 > 0.91). A reduced viscosity associated with ANH resulted in improved venous return, higher cardiac preload and increased cardiac output. In summary, this study demonstrated that ANH to a haemoglobin value of 8.6 g.dl(-1) was well tolerated in patients with coronary artery disease.

Adult↗

Cardiovascular response to acute normovolaemic haemodilution in patients with severe aortic stenosis: assessment with transoesophageal echocardiography.

Using multiplane transoesophageal echocardiography (TOE), we investigated the haemodynamic response to acute normovolaemic haemodilution (ANH) in anaesthetised patients with critical aortic stenosis. Twenty-eight patients were randomly assigned to ANH or control groups. In the control group, haemodynamic data remained unchanged over a 20-min period. In the ANH group, haemoglobin levels decreased from a mean (SD) of 134 (7) to 91 (9) g x l(-1) (p < 0.001) whereas stroke volume, central venous pressure and left ventricular (LV) end-diastolic area all increased significantly (mean (SD) +15 (6) ml; +2.0 (1.1) mmHg; +2.1 (0.8) cm2, respectively). During ANH, the accelerated blood flow through the stenotic valve caused an increased loss (SD) in LV stroke work: from 24 (8)% to 30 (10)%), (p < 0.01). Hence, lowering viscosity with ANH resulted in improved venous return, higher cardiac preload and increased stroke volume. However, this adaptive haemodynamic response was limited by less efficient LV stroke work due to dissipation of fluid kinetic energy.

Aged↗

Direct measurements of natural planktonic bacterial community viability by flow cytometry.

A range of fluorescent viability dyes were used in conjunction with flow cytometry to rapidly enumerate viable bacteria from freshwater environments. Optimal labelling was achieved by using carboxyfluorescein diacetate or chemchrome B with a detergent-mediated permeabilization step. The viable bacterial count under optimal conditions was 7% in oligotrophic lake water and 75% in polluted river water.

Journal Article↗