Consistency of results from the Vettest 8008 clinical biochemistry analyser.

Findings are presented on the precision of a clinical biochemistry analyser designed specifically for veterinary use. Twenty biochemical analytes have been examined in detail for variation within and between runs. The results indicate that the analyser can provide high precision for all the analytes with the possible exception of calcium, and suggest that the instrument can be used with confidence in the practice laboratory to aid diagnosis and to monitor biochemical changes in animals receiving treatment.

Animals

Servo-controlled indenter for determining the transverse stiffness of ventricular muscle.

Regional ventricular wall stress is a critical determinant of cardiac function. There are, however, no validated methods for accurately estimating this stress. We have shown in the isolated ventricular septum that, during steady-state indentations, the transverse stiffness (the ratio of indentation stress [pressure acting on indenter face] to indentation strain [amount of indentation/nonindented thickness]) can be used as an estimate of the in-plane wall stress. Because of the long acquisition time for those transverse stiffness determinations, it was not possible to follow changes in wall stress over a single contraction. We recently developed a dynamic indentation system that can determine transverse stiffness in as little as 10 ms, allowing estimation of wall stress over a single contraction cycle. The apparatus consists of an indentation probe coupled to a linear motor. This indentation system was tested on two beating canine ventricular septa that were mounted in a biaxial system the could apply strains in the plane of the septa and measure the resulting in-plane stresses. The probe indented the septa with peak displacements of 0.1-0.5 mm at frequencies of 20 and 50 Hz. The transverse stiffness was calculated as the slope of the relation between the indentation stress and indentation strain during each high-frequency indentation. Consistent with earlier studies, the transverse stiffness was related to the inplane stress. In contrast to earlier studies, however, these dynamic transverse stiffness determinations could be made during a single contraction. Thus, dynamic transverse stiffness determinations allow estimation of wall stress in the isolated septa by minimal surface contact, and may lead to methods for estimating wall stress in the intact heart.

Animals

An improved video-based computer tracking system for soft biomaterials testing.

We present an improved video-based computer system for on-line tracking of small markers moving in a plane. The system consists of a CCD camera, a video monitor, a dedicated 80386/20 microcomputer, a video frame grabber, and custom software. Up to four markers can be tracked at the 30-Hz video frame rate using a two-step, correlation-based search procedure. We discuss the requisite hardware and software requirements and illustrate how this tracking system can be used to collect strain data during biaxial stretching tests on planar soft tissues. Operating at 30 Hz, this system is an improvement over those previously reported, which are either slower or yield less information.

Algorithms

Effect of linoleic acid infusion on blood pressure in normotensive and hypertensive rats.

High dietary intake of linoleic acid lowers arterial pressure, and, in vitro, linoleic acid inhibits the enzymatic activity of renin. The purpose of the present study was 1) to evaluate the effect of intravenous infusion of linoleic acid on blood pressure in normotensive and hypertensive Sprague-Dawley rats and 2) to determine whether the hypotensive response to linoleic acid infusion is caused by inhibition of circulating renin. Blood pressure was decreased (P less than 0.01) by linoleic acid infusion in normotensive sodium chloride-deprived animals and in animals with two-kidney, one-clip hypertension. In contrast, linoleic acid infusion did not affect blood pressure in normotensive rats on a "normal" or high sodium chloride intake, in rats with deoxycorticosterone acetate (DOCA)-salt hypertension, and in anephric rats. In sodium chloride-deprived rats, the reduction of blood pressure by linoleic acid infusion was associated with increased plasma renin activity (P less than 0.05); serum angiotensin-converting enzyme activity was unchanged. The in vitro enzymatic activity of exogenous renin in plasma of anephric rats was not affected by linoleic acid infusion. In two-kidney, one-clip hypertensive animals, pretreatment with indomethacin did not alter the hypotensive response to linoleic acid. Thus, although linoleic acid infusion lowered blood pressure in high renin but not in low renin states, the reduction of blood pressure was not related to inhibition of circulating renin or to alterations of endogenous prostaglandin biosynthesis.

Animals

Isolation of subunits from trypsin-cleaved sarcoplasmic reticulum Ca2+ transport adenosine triphosphatase.

Controlled tryptic digestion of purified rat skeletal muscle sarcoplasmic reticulum (Ca2+ + Mg2+)-adenosine triphosphate yields two products designated Fragments 3a and 3b with molecular weights of 65,000 and 56,000 respectively. The isolation of these products in high yield should facilitate exploration of the molecular characteristics of this adenosine triphosphatase. A simple, rapid method for accomplishing this isolation was developed which provides a high yield and utilizes mild conditions. The fragments obtained by this method were used to determine the phospholipid and sulfhydryl contents of Fragments 3a and 3b. In addition, information was obtained on the orientation of these adenosine triphosphatase components in the enzyme lipoprotein complex.

Adenosine Triphosphatases

Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis.

Technetium-99m stannous pyrophosphate (99mTc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +/- 5.3 (mean +/- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal 99mTc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that 99mTc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis.

Animals

Trichosporon cutaneum endocarditis.

A 61-year-old man with Trichosporon cutaneum (T. cutaneum) prosthetic valve endocarditis is reported. He had had an aortic valve replacement for rheumatic heart disease 3 years earlier. Onset of the valve infection was subacute. A systolic murmur was noted on admission. Subsequently, he developed conjunctival hemorrhages, hematuria and transient episodes of confusion, aphasia and cranial nerve palsies. Three of 17 blood cultures taken over 3 weeks were positive for T. cutaneum. He was given amphotericin B (AmB) and 5-fluorocytosine (5FC); T. cutaneum infection of prosthetic aortic valve was identified. The aortic valve was replaced. Postoperatively he developed refractory ventricular fibrillation and died. Striking synergy to AmB-5FC and AmB-rifampin combinations was demonstrated in vitro.

Amphotericin B