PubMed Health⌕ Search

Biomedical subjects

J Duyck

Publications and source records attributed to J Duyck.

17 recordsLinked to original sources

The influence of micro-motion on the tissue differentiation around immediately loaded cylindrical turned titanium implants.

OBJECTIVE: The aim of this study was to evaluate the effect of various degrees of implant displacement on the tissue differentiation around immediately loaded cylindrical turned titanium implants. DESIGN: The experiments were conducted in repeated sampling bone chambers placed in the tibia of 10 rabbits. Tissues could grow into the bone chambers via perforations. Due to its double structure, tissues inside the chamber could be harvested leaving the chamber intact. This allowed several experiments within the same animal. The chambers contained a cylindrical turned titanium implant that was loaded in a well-controlled manner. In each of the 10 chambers, four experiments were conducted with the following test conditions: immediate implant loading by inducing 0 (control), 30, 60 and 90 microm implant displacement, 800 cycles per day at a frequency of 1 Hz, twice a week during a period of 6 weeks. Histological and histomorphometrical analyses were performed on methylmethacrylate histological sections. An ANOVA was conducted on the dataset. RESULTS: The total tissue volume was significantly lowest in the unloaded control condition. The bone volume fraction on the other hand, was significantly larger in the unloaded and 90 microm implant displacement, compared to the 30 microm implant displacement. Bone density increased with increasing micro-motion with significantly higher values for the 60 microm- and 90 microm-test conditions compared to the unloaded situation. The chance to have bone-to-implant contact decreased in case of micro-motion at the tissues-implant interface. CONCLUSION: The magnitude of implant displacement had a statistically significant effect on the tissue differentiation around immediately loaded cylindrical turned titanium implants. Implant micro-motion had a detrimental effect on the bone-to-implant contact in an immediate loading regimen.

Animals↗

Numerical simulation of tissue differentiation around loaded titanium implants in a bone chamber.

The application of a bone chamber provides a controlled environment for the study of tissue differentiation and bone adaptation. The influence of different mechanical and biological factors on the processes can be measured experimentally. The goal of the present work is to numerically model the process of peri-implant tissue differentiation inside a bone chamber, placed in a rabbit tibia. 2D and 3D models were created of the tissue inside the chamber. A number of loading conditions, corresponding to those applied in the rabbit experiments, were simulated. Fluid velocity and maximal distortional strain were considered as the stimuli that guide the differentiation process of mesenchymal cells into fibroblasts, chondrocytes and osteoblasts. Mesenchymal cells migrate through the chamber from the perforations in the chamber wall. This process is modelled by the diffusion equation. The predicted tissue phenotypes as well as the process of tissue ingrowth into the chamber show a qualitative agreement with the results of the rabbit experiments. Due to the limited number of animal experiments (four) and the observed inter-animal differences, no quantitative comparison could be made. These results however are a strong indication of the feasibility of the implemented theory to predict the mechano-regulation of the differentiation process inside the bone chamber.

Animals↗

The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study.

Although it is generally accepted that adverse forces can impair osseointegration, the mechanism of this complication is unknown. In this study, static and dynamic loads were applied on 10 mm long implants (Brånemark System, Nobel Biocare, Sweden) installed bicortically in rabbit tibiae to investigate the bone response. Each of 10 adult New Zealand black rabbits had one statically loaded implant (with a transverse force of 29.4 N applied on a distance of 1.5 mm from the top of the implant, resulting in a bending moment of 4.4 Ncm), one dynamically loaded implant (with a transverse force of 14.7 N applied on a distance of 50 mm from the top of the implant, resulting in a bending moment of 73.5 Ncm, 2.520 cycles in total, applied with a frequency of 1 Hz), and one unloaded control implant. The loading was performed during 14 days. A numerical model was used as a guideline for the applied dynamic load. Histomorphometrical quantifications of the bone to metal contact area and bone density lateral to the implant were performed on undecalcified and toluidine blue stained sections. The histological picture was similar for statically loaded and control implants. Dense cortical lamellar bone was present around the marginal and apical part of the latter implants with no signs of bone loss. Crater-shaped bone defects and Howship's lacunae were explicit signs of bone resorption in the marginal bone area around the dynamically loaded implants. Despite those bone defects, bone islands were present in contact with the implant surface in this marginal area. This resulted in no significantly lower bone-to-implant contact around the dynamically loaded implants in comparison with the statically loaded and the control implants. However, when comparing the amount of bone in the immediate surroundings of the marginal part of the implants, significantly (P < 0.007) less bone volume (density) was present around the dynamically loaded in comparison with the statically loaded and the control implants. This study shows that excessive dynamic loads cause crater-like bone defects lateral to osseointegrated implants.

Animals↗

Evaluation of factors influencing the marginal bone stability around implants in the treatment of partial edentulism.

BACKGROUND: The original protocol of Brånemark to achieve predictable osseointegration for oral implants has substantially been modified. One may question whether results are influenced by those modifications, especially for the long-term prognosis. PURPOSE: The goal of the present study was to investigate the impact of those parameters that deviate from the original protocol as defined by P-I Brånemark. MATERIALS AND METHODS: In this study, 246 patients with 263 fixed partial prostheses supported by 668 Brånemark implants were followed from 1 to 15 years (mean: 6.3 yr). Radiographs were taken at the time of abutment connection, at 3 to 6 months, at 12 months, and then every 3 years. The bone level was rated mesially and distally from the implants on a total of 2588 radiographs. RESULTS: A positive relation between abutment length and marginal bone level was found (p > .0001). The maxilla (p = .03), porcelain (p = .007), long abutments (p = .008), and regular-sized diameter implants (p = .001) all exhibited more bone loss in the first 6 months. After 6 months, only long implants showed more bone loss (p = .03). CONCLUSIONS: Overall, the marginal bone level remained stable around Brånemark implants, never surpassing 2.2 mm, even after 15 years. Although longer implants lost more bone over time, this has to be interpreted with respect to higher resorption rates in less resorbed jaws.

Adult↗

Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.

The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.

Adult↗

Time dependent failure rate and marginal bone loss of implant supported prostheses: a 15-year follow-up study.

This study deals with 4971 implants (Brånemark system) installed in 1315 patients, either fully or partially edentulous, and followed from implant installation up to the last control. A predominance of female patients (61%) and a nearly equal number of upper and lower jaws characterised the study group. Patients were scheduled each 6-12 months for recall. The observation time varied from 0.5 to 15 years (mean 5.1). The whole cohort was split up into compromised (n = 59) and non-compromised (n = 1256) patients. The former are defined as grafted (autologous bone) and patients irradiated in the head and neck area. In the compromised patients 24 out of 59 patients (40.6%) showed failures, in whom 59 out of 310 (19%) implants failed. In the non-compromised patients, implant failures were observed in 11.6% of the patients, which corresponds to 5.9% of the installed implants, excluding iatrogenic failures. Failures were further divided chronologically into early (up to 1 year after abutment connection) and late failures. There were early implant failures in 12.5% of the compromised patients and in 3.4% of the others. Late implant failures occurred in 7.4 and 2% of the two patients groups, respectively. While gender did not affect the failure rate, implant lengths, corresponding to the available bone height did, since a 21.5% failure rate for the 7-mm implants contrasts with 4.1 and 3.8% for 13- and 15-mm implants, respectively. Early as well as annual late failures are more frequently found in the maxilla. Implant fractures only occurred in the fixed (both partial and full) prosthesis group but never surpassed the 0.2% annual level. Marginal bone loss, exceeding the third screw thread occurred in 1.8% of the implants at the last control. It appears that this type of implant configuration offers a high long-term predictability. Failures occur before, at or during the first year after abutment connection and in very short implants. Marginal bone as a whole is very stable over the years.

Adolescent↗

Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: an in vivo study.

Since loading is increasingly believed to be a determining factor in the treatment outcome with oral implants, there is a need to expand the knowledge related to the biomechanics of oral implants. The aim of this study is to gain insight in the distribution and magnitude of occlusal forces on oral implants carrying fixed prostheses. This is done by in vivo quantification and qualification of these forces, which implies that not only the magnitude of the load but also its type (axial force or bending moment) will be registered. A total of 13 patients with an implant supported fixed full prosthesis were selected. Occlusal forces on the supporting implants were quantified and qualified during controlled load application of 50 N on several positions along the occlusal surface of the prostheses and during maximal biting in maximal occlusion by use of strain gauged abutments. The test was conducted when the prostheses were supported by all (5 or 6) implants and was repeated when the prostheses were supported by 4 and by 3 implants only. Despite considerable inter-individual variation, clear differences in implant loading between these test conditions were seen. Loading of the extension parts of the prostheses caused a hinging effect which induced considerable compressive forces on the implants closest to the place of load application and lower compressive or tensile forces on other implants. On average, higher forces were observed with a decreasing number of supporting implants. Bending moments were highest when 3 implants only were used.

Adult↗

Three-dimensional force measurements on oral implants: a methodological study.

This paper describes a methodology that allows in vitro and in vivo quantification and qualification of forces on oral implants. Strain gauges are adapted to the outer surface of 5.5 and 7 mm standard abutments (Brånemark System, Nobel Biocare, Sweden). The readings of the strain gauges are transformed into a numerical representation of the normal force and the bending moment around the X- and Y-axis. The hardware and the software of the 3D measuring device based on the strain gauge technology is explained and its accuracy and reliability tested. The accuracy level for axial forces and bending moments is 9.72 N and 2.5 N x cm, respectively, based on the current techniques for strain gauged abutments. As an example, an in vivo force analysis was performed in a patient with a full fixed prosthesis in the mandible. Since axial loads of 450 N and bending moments of 70 N x cm were recorded, it was concluded that the accuracy of the device falls well within the scope of our needs. Nevertheless, more in vivo research is needed before well defined conclusions can be drawn and strategies developed to improve the biomechanics of oral implants.

Aged↗

Influence of prosthesis material on the loading of implants that support a fixed partial prosthesis: in vivo study.

BACKGROUND: Since loading is increasingly believed to be a determining factor in the treatment outcome with oral implants, there is a need to expand the knowledge related to the biomechanics of oral implants and its influencing factors. PURPOSE: The aim of this study was to investigate the influence of prosthesis material on the distribution and magnitude of load on oral implants carrying a fixed partial prosthesis by in vivo quantification and qualification of this load. METHODS: Eight patients with in total nine three-unit fixed partial prostheses on three implants and three patients with in total four two-unit fixed partial prostheses on two implants were selected. Both metal and acrylic resin prostheses were made. Strain gauged abutments were used to measure the load on the supporting implants during controlled load application of 50 N on several positions along the occlusal surface of the prostheses and during maximal biting in maximal occlusion. Additional tests were conducted when the three-unit prostheses were supported only by two implants, thereby creating an extension pontic. RESULTS: A significantly better distribution of bending moments with the metal prostheses in comparison to the acrylic resin prostheses was observed in the case of the three-unit prostheses on two implants. No other difference in load or load distribution with the different prosthesis materials was noted. CONCLUSION: The clinical significance of the study reveals an increased risk for bending overload of the implants that are closest to the point of load application only in the case of acrylic resin long span prostheses or acrylic resin prostheses with extensions.

Acrylic Resins↗

Biologic outcome of single-implant restorations as tooth replacements: a long-term follow-up study.

BACKGROUND: The replacement of a single tooth or several teeth by means of single-implant restorations is an increasingly used method that needs long-term validation. PURPOSE: The goal of this study was to evaluate the outcome of single-implant restorations by means of fixed restorations and to define the prognosis through marginal bone level estimations. MATERIALS AND METHODS: From November 1986 to June 1998, 270 Brånemark implants (215 in the upper jaw) were installed in 219 patients (106 males). Both anterior and posterior sites were involved. Of the 263 single restorations, 28 were placed in private dental offices. The patients were followed until June 1999. RESULTS: Twelve implants failed before or at abutment connection or within 6 months afterward. Only four implants failed later. The cumulative success rates were 93% for the implants and 96.5% for the restorations over a period of 11 years. The marginal bone loss during the first 6 months after abutment connection reached 0.71 mm and then dropped to 0.036 mm annually over a period of 10 years. CONCLUSIONS: Single-implant restorations (Brånemark System) are a reliable treatment with a good long-term prognosis. Failures were concentrated during the healing period and early loading phase.

Adolescent↗

Use of microfocus computerized tomography as a new technique for characterizing bone tissue around oral implants.

Qualitative and quantitative analysis of peri-implant tissues around retrieved oral implants is typically done by means of light microscopy on thin histological sections containing the metal surface and the undecalcified bone. It remains, however, a labor-intensive and thus time-consuming job. Moreover, it is a destructive technique that allows tissue quantification in only a limited number of two-dimensional sections. As an alternative, we evaluated the bone structure around screw-shaped titanium implants by means of microfocus computerized tomography (micro-CT) because it presents a number of advantages compared to conventional sectioning techniques: micro-CT is nondestructive, fast, and allows a fully three-dimensional characterization of the bone structure around the implant. Images can be reconstructed in an arbitrary plane, and three-dimensional reconstructions are also possible. Because of its high resolution, individual trabeculae can be visualized. The accuracy of micro-CT was qualitatively evaluated by comparing histological sections with the corresponding CT slices for the same specimen. The overall trabecular structure is very similar according to both techniques. Even very close to the interface, the titanium implant does not seem to produce significant artifacts. Furthermore, because the complete digital data on the trabecular bone structure around the implant is available, it is possible to create finite-element models of the bone-implant system that model the trabeculae in detail so that mechanical stress transfer at the interface can be studied at the level of individual trabeculae. Therefore, micro-CT seems to be very promising for the in vitro assessment of the three-dimensional bone structure around oral implants. Further research will be needed to evaluate its accuracy in a more quantitative way.

Animals↗

In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system.

This study was designed to gain insight into the influence of the attachment system on the loading conditions of oral implants supporting a mandibular overdenture on two implants. Five patients were selected and were provided with two implants in the canine area of the mandible (Brånemark System). All patients received a new mandibular overdenture that could be mounted on an ovoid-shaped bar (Dolder, C&M): (a) with and (b) without bilateral extensions and (c) on ball-attachments (Nobel Biocare). Using three strain gauges attached to the outer surface of the 5.5-mm standard abutments, the axial forces and bending moments on both supporting implants could be quantified. Load registrations were made during application of 50 N on seven predetermined positions along the occlusal surface of the prosthesis and during maximal biting in maximal occlusion (clenching). The results revealed no differences in induced axial force for the various anchorage devices, unlike the differences in bending moment. Although there is a tendency for better axial load sharing with bars and better sharing of bending moments with ball attachments, these differences were not significant.

Dental Implantation, Endosseous↗

Failure of oral implants: aetiology, symptoms and influencing factors.

The use of oral implants opened a wide range of prosthetic treatment possibilities in edentulous patients. Although the reported success rates of oral implants are high, failures do occur. This paper reviews the current knowledge about the aetiology, the signs and symptoms and the possible influencing factors of implant failure. Possible causes of implant failure are thought to be infection of the periimplant tissues, occlusal overload, or a combination of both. Nevertheless, pinpointing one of these as the aetiological factor in a particular case is difficult and should be handled reluctantly. Although the cause might seem obvious, influencing factors could play a role as well. Gaining insight into these processes might stimulate the adoption of preventive action and therefore increase the predictability of the treatment outcome with oral implants.

Dental Implants↗

The influence of bone mechanical properties and implant fixation upon bone loading around oral implants.

Finite element models were created to study the stress and strain distribution around a solitary Brånemark implant. The influence of a number of clinically relevant parameters was examined: bone-implant interface (fixed bond versus frictionless free contact), bone elastic properties, unicortical versus bicortical implant fixation and the presence of a lamina dura. Bone loading patterns in the vicinity of the implant seem to be very sensitive to these parameters. Hence they should be integrated correctly in numerical models of in vivo behaviour of oral implants. This necessitates the creation of patient-dependent finite element models.

Biomechanical Phenomena↗

Biomechanics of oral implants: a review of the literature.

Considering biomechanics of oral implants, both loading on the implant itself and the transferred load to the bone need our attention. Mastication induces vertical and transverse forces, which induce axial forces and bending moments and exert stress gradients in the implant as well as in the bone. By the use of strain gauges or piezo-electric force transducers, one succeeds in precise intra-oral force measurements which make it possible to study a wide range of varying conditions in implant dentistry. A key determinant of the success or failure of an oral implant is the way mechanical stresses are transferred to the surrounding bone. The load transfer from implants to surrounding bone depends on the type of loading, the bone-implant interface, the length and diameter of the implants, the implant shape, structure of the implant surface, the superstructure and the quality and quality of the surrounding bone. Finite element analyses indicate maximum stress concentrations in the contact area of the implants with the cortical bone and around the apex of the implants in the trabecular bone. Although the precise mechanisms are not fully understood, it is clear that there is an adaptive remodelling response of the surrounding bone to the current situation.

Biomechanical Phenomena↗

Assessment of mechanobiological models for the numerical simulation of tissue differentiation around immediately loaded implants.

Nowadays, there is a growing consensus on the impact of mechanical loading on bone biology. A bone chamber provides a mechanically isolated in vivo environment in which the influence of different parameters on the tissue response around loaded implants can be investigated. This also provides data to assess the feasibility of different mechanobiological models that mathematically describe the mechanoregulation of tissue differentiation. Before comparing numerical results to animal experimental results, it is necessary to investigate the influence of the different model parameters on the outcome of the simulations. A 2D finite element model of the tissue inside the bone chamber was created. The differentiation models developed by Prendergast, et al. ["Biophysical stimuli on cells during tissue differentiation at implant interfaces", Journal of Biomechanics, 30(6), (1997), 539-548], Huiskes et al. ["A biomechanical regulatory model for periprosthetic fibrous-tissue differentiation", Journal of Material Science: Materials in Medicine, 8 (1997) 785-788] and by Claes and Heigele ["Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing", Journal of Biomechanics, 32(3), (1999) 255-266] were implemented and integrated in the finite element code. The fluid component in the first model has an important effect on the predicted differentiation patterns. It has a direct effect on the predicted degree of maturation of bone and a substantial indirect effect on the simulated deformations and hence the predicted phenotypes of the tissue in the chamber. Finally, the presence of fluid also causes time-dependent behavior. Both models lead to qualitative and quantitative differences in predicted differentiation patterns. Because of the different nature of the tissue phenotypes used to describe the differentiation processes, it is however hard to compare both models in terms of their validity.

Animals↗

Within-subject comparison between connected and nonconnected tooth-to-implant fixed partial prostheses: up to 14-year follow-up study.

PURPOSE: This long-term follow-up study aimed to compare the outcome of fixed prostheses supported by teeth and implants and by freestanding implants only. MATERIALS AND METHODS: From prosthesis insertion up to 14 years (mean 6.5 y), 18 patients were followed. Implant-supported prostheses with and without tooth connection were compared within the same jaw. The tooth-implant prostheses were supported by 30 implants and 30 teeth, and the freestanding prostheses were supported by 48 implants. Implant outcome, marginal bone stability, and mechanical complications were recorded. RESULTS: Neither implant mobility nor fractures of any component of the implants were observed. No prosthesis complications were observed, and the same applied for crown cement failure and intrusion of teeth. Only one periapical lesion was detected at the first follow up. The annual change of the marginal bone level around connected and freestanding implants did not differ significantly. The mean marginal bone loss (over the 2 groups) for the first 6 months amounted to 1.08 mm. After the first 6 months, an annual marginal bone loss of 0.015 mm was observed. There was no difference between the 3 connection types (single implant connected to single tooth, multiple implants and/or multiple teeth connected with single connector, and multiple connectors) for the first 6 months or thereafter. The marginal bone loss (over the 3 groups) for the first 6 months was 1.15 mm. After the first 6 months, the annual bone loss (over the 3 groups) amounted to 0.015 mm. CONCLUSION: Based on the results of this study, splinting teeth with implants for implant-supported fixed prostheses did not affect the long-term outcome in comparison to freestanding implants.

Adult↗