PubMed HealthSearch

Biomedical subjects

J E Baumgardner

Publications and source records attributed to J E Baumgardner.

6 recordsLinked to original sources

Modelling steady state pulmonary elimination of He, SF6 and CO2: effect of morphometry.

We studied the influence of acinar morphometry on the shape of simulated expirograms computed from a single path convection-diffusion model that includes a source term for gas evolution from the blood (Scherer et al., J. Appl. Physiol. 64: 1022-1029, 1988). Acinar structure was obtained from published data of 3 different lung morphometries. The simulations were performed over a range of tidal volumes (VT) and breathing frequencies (f) comparable to those observed in a previously reported human study. Airways dead space (VDaw) increased with VT in all the morphometric models tested and in the experimental data. The increase in VDaw with VT was inversely related to the diffusivity of the evolving gas and to the rate of increase in airway cross-section of the most mouthward (proximal) alveolated generations of the models. Normalized phase III slope for all the gases decreased with increasing VT in all the models as was previously reported for healthy human subjects. In the model simulations, the greatest sensitivity of phase III slope to VT was seen with the least diffusible gas using the airway morphometry with the smallest cross-sectional areas in the proximal alveolated generations. We conclude that both VDaw and phase III slope of an evolving gas are sensitive to the geometry of the proximal acinar airways and that this is manifest by their dependence on tidal volume, breathing frequency, molecular diffusivity and alveolar/blood source emission rate. The model simulations indicate that heterogeneity of gas washout is not required to explain the magnitude of the phase III slope in healthy human subjects.

Carbon Dioxide

Diffusivity, respiratory rate and tidal volume influence inert gas expirograms.

We modified, and developed software for, a computer-controlled quadrupole mass spectrometer to measure complete breath-by-breath expirograms of helium (He) and sulfur hexafluoride (SF6) exhaled during the infusion of saline saturated with the inert gases. He and SF6 have similar blood solubilities but very different gas phase diffusivities allowing examination of the influence of gas phase diffusivity on steady state inert gas expirograms. We studied six normal human volunteers in nine separate studies and examined the influence of tidal volume (VT) and breathing frequency (f) on the airways dead space (VDaw) and alveolar plateau slope (phase III) for the inert gases and CO2. The experimental data showed a reduction in VDaw with rapid shallow breathing, while phase III slope increased by a factor of two to three. We critically evaluated the data and methodology of these and previously reported studies of continuous and single breath washout of He and SF6. In general the 15 to 20 ml differences in VDaw between He and SF6 were in keeping with previous studies by others. The ratio of phase III slopes of SF6 to He reported by us previously (Scherer et al., J. Appl. Physiol. 64: 1022-1029, 1988) was 3.13. In the current study, which includes the analysis of more than 400 He and SF6 breaths, the ratio of SF6 to He slope was 1.85. The difference between the two studies was largely related to the improved methodology of the current study, particularly for the measurement of He. The results support the conclusion that diffusivity is an important component of both phase II and phase III of the expirogram. However, the difference in phase III between He and SF6 is somewhat less than previously reported.

Adult

Skin blood flow from gas transport: helium xenon and laser Doppler compared.

A study was designed to compare three independent measures of cutaneous blood flow in normal healthy volunteers: xenon-133 washout, helium flux, and laser velocimetry. All measurements were confined to the volar aspect of the forearm. In a large group of subjects we found that helium flux through intact skin changes nonlinearly with the controlled local skin temperature whereas helium flux through stripped skin, which is directly proportional to skin blood flow, changes linearly with cutaneous temperature over the range 33 degrees to 42 degrees. In a second group of six volunteers we compared helium flux through stripped skin to xenon-133 washout (intact skin) at a skin temperature of 33 degrees, and we found an essentially linear relationship between helium flux and xenon measured blood flow. In a third group of subjects we compared helium flux blood flow (stripped skin) to laser doppler velocimetric (LDV) measurements (intact skin) at adjacent skin sites and found a nonlinear increase in the LDV skin blood flow compared to that determined by helium over the same temperature range. A possible explanation for the nonlinear increases of helium flux through intact skin and of LDV output with increasing local skin temperature is that they reflect more than a change in blood flow. They may also reflect physical changes in the stratum corneum, which alters its diffusional resistance to gas flux and its optical characteristics.

Blood Flow Velocity

Numerical and experimental study of steady-state CO2 and inert gas washout.

The predictions of a single-path trumpet-bell numerical model of steady-state CO2 and infused He and sulfur hexafluoride (SF6) washout were compared with experimental measurements on healthy human volunteers. The mathematical model used was a numerical solution of the classic airway convention-diffusion equation with the addition of a distributed source term at the alveolar end. In the human studies, a static sampling technique was used to measure the exhaled concentrations and phase III slopes of CO2, He, and SF6 during the intravenous infusion of saline saturated with a mixture of the two inert gases. We found good agreement between the experimentally determined normalized slopes (phase III slope divided by mixed expired concentration) and the numerically determined normalized slopes in the model with no free parameters other than the physiological ones of upper airway dead space, tidal volume, breathing frequency, and breathing pattern (sinusoidal). We conclude 1) that the single-path (Weibel) trumpet-bell anatomic model used in conjunction with the airway convection-diffusion equation with a distributed source term is adequate to describe the steady-state lung washout of CO2 and infused He and SF6 in normal lungs and 2) that the interfacial area separating the tidal volume fron from the functional residual capacity gas, through which gas diffusion into the moving tidal volume occurs, exerts a major effect on the normalized slopes of phase III.

Carbon Dioxide