Forty-one variables following thoracotomy in calves.

Seven calves underwent thoracotomy to study the response of 41 physiologic variables over a 14 day post-operative period for comparison to a recent series of left ventricular bypass pump implants. The experimental protocols were identical to the pump implant protocols except that the sham operated animals did not receive antiplatelet or anticoagulant drugs and the pumps were not implanted. Of the 41 variables studied, 13 changed significantly during the post-operative period. Heart rate, hematocrit, whole blood hemoglobin, and fibrinogen concentration decreased, while fibrinogen survival, stroke volume, cardiac output, arterial blood pH, pCO2 and pO2, plasma sodium concentration, and urinary excretion rates of sodium and potassium increased from the first or second to the fourteenth post-operative day. Heart rate and hematocrit also decreased in the recent series of 18 animals in which left ventricular bypass pumps were implanted. The decrease in heart rate is toward the unoperated control value as the calves recover from the operative stress. The decrease in hematocrit is probably the result of daily removal of blood for the physiologic studies because there was no evidence of hemorrhage or red blood cell destruction.

Animals↗

Recent experience with the Baylor left ventricular bypass pump.

The current Baylor left ventricular bypass pump is a pneumatically actuated diaphragm pump lined with segmented polyurethane. It is a swirl design in which blood moves in a circular motion within the pump. It has tilting disc inflow and outflow valves and the stroke volume is 60 ml. It is intended for periods of use up to fourteen days. Eighteen devices have been implanted in normal calves. The mean duration of pump operation was eleven days. The pump-canula junctions and regions of the valve seats have been sites of thrombus formation and are being redesigned to eliminate areas of flow separation and stasis.

Animals↗

Left ventricular failure in calves produced by supravalvular aortic stenosis.

A stable model of left ventricular failure is required to test left ventricular assist devices. Supravalvular aortic constriction will cause left atrial pressure to rise to new levels which are stable for several days. When left atrial pressure becomes unstable, an automatically actuated left ventricular assist device will increase its output and prevent pulmonary edema.

Animals↗

Correlation of peak aortic and carotid flow acceleration during coronary occlusion in conscious baboons.

1. Peak blood flow acceleration measured in the common carotid artery was compared with peak flow acceleration measured in the ascending aorta of three baboons. 2. The response to occlusion for 60s of the circumflex branch or the anterior descending branch of the left coronary artery was investigated. 3. Both accelerations decreased approximately to the same extent. Peak aortic flow velocity, stroke volume and cardiac output also decreased but to a smaller extent. 4. It is concluded that peak aortic flow acceleration is a sensitive index of myocardial function during acute coronary occlusion in conscious primates and that peak carotid flow acceleration is an indirect measure of myocardial performance under the same conditions.

Animals↗

Left ventricular dynamics of trained dogs anesthetized with methohexital.

The cardiac response to intravenous administration of the ultrashort-acting oxybarbiturate anesthetic, methohexital sodium, was studied in trained dogs. Heart rate increased immediately and gradually declined to the control value 60 minutes later. Stroke volume decreased immediately, reversed transiently, and decreased again, to return gradually to the control value at one hour. Peak aortic flow velocity and peak aortic flow acceleration paralleled the triphasic response of stroke volume. Cardiac output decreased initially, then increased to above the control value to a maximum at the time of maximum heart rate, then decreased again to below the control value by 30 minutes. From 30 minutes to 60 minutes cardiac output gradually returned to the control value.

Anesthesia, Intravenous↗

Effect of fluocinolone acetonide cream on human skin blood flow.

Blood flow rate was measured in the forearm skin of human subjects exposed to ultraviolet irradiation. Blood flow was determined by the 133Xe disappearance technique 18 hr after ultraviolet (UV) irradiation with a Westinghouse RS sunlamp held 10 inches from the skin for 10 min. Ultraviolet irradiation caused skin blood flow to increase. Application of fluocinolone acetonide cream, 0.025%, 4 times in the 16 hr following UV irradiation had no effect on either control skin blood flow or the UV-induced hyperemia.

Administration, Topical↗