A comparison of biparietal diameter measurements using a real-time scanner and a conventional scanner equipped with a coded cephalometry system.

In 131 patients a comparison was made between measurements obtained using a real-time scanner and those obtained using a conventional "B" scanner with an attached "coded cephalometry system": 69 per cent of the readings agreed within +/- 2 mm and, when the "B" scan reading was considered "good", 90 percent fell within this range. Between 14 and 28 weeks, gestational age diagnoses using the two methods were within one week of each other in 88 of 89 patients.

Cephalometry↗

A method for checking the registration of contact B-scanners.

The use of an ultrasonic delay line and mechanical arm as a means of checking the registration of contact B-scanners is described. The principle of operation is applicable to any make of equipment. The amount of misregistration can be assessed, and discontinuities or departures from the normal can be demonstrated in the transducer position sensing system. As an added benefit it is a rapid means of checking both picture size and the accuracy of electronic markers.

Ultrasonics↗

A critical evaluation of sonar "crown-rump length" measurements.

In a study to evaluate the reproducibility and accuracy of the sonar technique of measurement of the in vivo fetal crown-rump length (Robinson, 1973), a series of in vivo and in vitro experiments was performed in which the random and systematic errors inherent in the technique were assessed. The potential sources of random error were those of operator judgement, movement of the fetus and mother, machine sensitivity settings and measurement from the photograph; while the sources of systematic error were those of oscilloscope scale factor, and velocity calibration inaccuracies, and the effect of beam width. The overall effect of the random errors, that is, the reproducibility of the technique, was assessed in an in vivo blind trial in which three independent measurements were made of the fetus. In a series of 30 experiments the average standard deviation of the three readings was found to be 1.2 mm. Evaluation of the systematic errors by in vivo experimentation, on the other hand, showed that the basic sonar measurements were in error by an overestimate of 1 mm for the beam width effect and 3.7 per cent for the scale factor and velocity calibration errors. A weighted non-linear regression analysis of 334 measurements was performed in order to obtain a "curve of best fit" for the period covering 6 to 14 weeks of menstrual age. The values obtained were corrected for the systematic errors and compared with widely quoted anatomical figures. In the second part of this investigation the original data was further analyzed to determine on a statistical basis the accuracy of the technique as a method of estimating maturity. It was shown that such an estimate could be made to within 4.7 days with a 95 per cent probability on the basic of a single measurement, and to within 2.7 days if three independent measurements were made.

Anthropometry↗

Nephrosonography in infants and children: a new technique.

A technique has been developed for the ultrasonic investigation of renal disease in infants using a specially designed water-bath with a conventional ultrasonic scanner. This permits ultrasonic studies of the renal tract from the neonatal period onwards; the procedure does not distress the child and the water acts as an excellent coupling medium.

Age Factors↗

Chromosome breakage and ultrasound.

Human lymphocyte cultures were examined for chromosome damage after exposure to ultrasound. Control and treated slides were scored "blind" and showed no evidence of damage due to ultrasound. Neither was there evidence of chromosome damage in blood cultures from six infants whose mothers had ultrasound during pregnancy when compared with that from six infants whose mothers had not. Our results suggest that if diagnostic ultrasound causes chromosome damage it does so with less frequency than acceptable levels of diagnostic x-irradiation.

Adult↗

Semi-dry electroblotting of DNA.

A procedure is described for the rapid transfer of DNA from agarose gels to nylon membranes using the semi-dry electroblotting technique. A Hind III digest of lambda DNA which was separated in a 1% agarose gel containing Tris, Borate, and EDTA (pH 8.0) was employed for the electrotransfer experiments. Transfer efficiency was determined by staining the DNA on the nylon membranes with a colloidal iron reagent. Current densities of 3-5 mA/sq. cm of gel permitted the transfer of high (23 kb) and low (0.3 kb) molecular weight fragments within 15 min. However, efficient transfer required a high ionic strength buffer that would prevent uneven dehydration of the agarose gel. Critical parameters for the transfer of nucleic acids with the semi-dry technique are discussed.

Bacteriophage lambda↗