An evaluation of the Bio-Rad Variant Haemoglobin Testing System for the detection of haemoglobinopathies.

The Bio-Rad Variant Haemoglobin Testing System is an automated analyser which uses the principle of cation exchange high performance liquid chromatography. This evaluation was undertaken to examine the effectiveness of the instrument as a screening mechanism to assist in the diagnosis of haemoglobinopathies. The ability to quantify haemoglobins A2 and F and to 'flag' other haemoglobin variants was tested. Within-batch precision was excellent and between-batch precision was good. Linearity and sensitivity compared favourably with the manufacturer's published ranges. The level of carry-over for haemoglobins F, S and A was less than 0.25%. The mean carry-over for haemoglobin A2 was 2.08%. This higher figure reflected the smaller absolute difference between the high and low samples for this parameter. The instrument never failed to indicate the presence of an abnormal haemoglobin in 271 selected samples. The instrument was reliable throughout the evaluation and at no time was a run aborted.

Cations↗

Influence of azathioprine on the ferrokinetics of patients with renal failure before and after treatment with erythropoietin.

In 16 patients (9 on azathioprine, 7 not) the ineffective iron turnover (IIT) was much higher in the azathioprine group (62.7 +/- 6.7 vs. 23.5 +/- 3.5 mumol/l blood/day, p < 0.0001, 2-tailed t test), though the red cell iron turnover (RCIT) was similar (42.8 +/- 2.9 vs. 41 +/- 4.8). Erythropoietin improved the anaemia in all patients and raised the RCIT (4 still on azathioprine to 72.2 +/- 9.8, p < 0.003; 7 non-azathioprine patients to 62.7 +/- 5.3, p < 0.01); the IIT remained higher in the azathioprine-treated (85.5 +/- 19.3 vs. 37.1 +/- 5.4; p < 0.013). In 2 patients who discontinued azathioprine, the IIT declined markedly to normal. In summary, azathioprine exacerbates the anaemia of renal failure by augmenting ineffective erythropoiesis, while erythropoietin benefits those on azathioprine as much as other renal patients by stimulating both effective and ineffective erythropoiesis.

Anemia↗

Effects of azathioprine on response of renal anaemia to subcutaneous recombinant human erythropoietin.

AIMS: To determine the effect of concomitant azathioprine treatment on the response of patients with renal failure to treatment with subcutaneous recombinant human erythropoietin (r-HuEPO). METHODS: Two groups of patients with renal failure not receiving haemodialysis were studied. One comprised seven patients receiving erythropoietin alone, the second consisted of nine patients who were also treated with azathioprine. The haematological changes were monitored, and the functional erythropoietic response was studied by two different ferrokinetic models. One analysed the initial, the other the extended plasma iron clearance. Studies were performed before r-HuEPO treatment on all 16 patients, and repeated on 11 of these when the target haemoglobin (10-11 g/dl) was achieved and stabilised. Total erythropoiesis was determined using both techniques. Analysis of the extended plasma iron clearance also permitted calculation of both effective and ineffective erythroid activity. RESULTS: The haematological response to r-HuEPO was the same for both patient groups. Measurement of total erythropoiesis by both ferrokinetic methods showed good correlation. For those receiving long term azathioprine, the percentage ineffective erythropoiesis was high compared with that of the other patients, and remained so for as long as they continued with azathioprine. For those uncomplicated by azathioprine treatment, r-HuEPO increased levels of both effective and ineffective erythropoiesis by the same degree. A substantial reduction in ineffective erythropoiesis was shown only by those patients who either discontinued or reduced their azathioprine once they started r-HuEPO treatment. CONCLUSIONS: Azathioprine increases ineffective erythropoiesis. In this study, the r-HuEPO dose was sufficient to overcome this effect and promoted effective erythropoiesis so that the anaemia lessened. Measurement of total erythropoiesis provided limited information on the functional changes involved, differentiation of effective from ineffective erythropoiesis being necessary to define the changes after azathioprine reduction or withdrawal.

Anemia↗

High incidence of type II autoantibodies in pernicious anaemia.

AIMS: To investigate the incidence of type II autoantibodies to intrinsic factor in pernicious anaemia. METHODS: Three hundred and forty four serum samples submitted for intrinsic factor antibody (IFAB) analysis on clinical or laboratory grounds were tested by an established radioassay and a new enzyme linked immunosorbent assay (ELISA) method for type I and total IFAB, respectively. Sixty of these were found to be positive by ELISA; this method was used to test further, 40 samples of adequate volume for types I and II antibodies. RESULTS: Type II antibodies were detected in 39 of the 40 sera tested. A comparative analysis indicated that seven samples contained pure type II antibody, being positive for total and type II by ELISA, but negative for type I by both the ELISA and radioassay technique. CONCLUSIONS: The occurrence of type II antibody, both alone and in combination with type I, seems to be more common than has previously been recognised, and emphasises the advantage of using a technique which will detect both types of antibody.

Anemia, Pernicious↗

Comparative ferrokinetic study with initial and extended iron clearance models.

Erythrokinetic studies were performed on 10 patients with chronic myelofibrosis and 11 patients with myelodysplasia (MDS). Values for plasma iron turnover, marrow iron turnover, and erythron transferrin uptake were derived using two ferrokinetic models. One entailed analysis of the extended plasma iron clearance over a number of days, the other comprised analysis of the initial plasma iron clearance during the first few hours of the study. A close correlation was found between the variables quantifying total erythropoiesis (marrow iron turnover and erythron transferrin uptake) in the two methodologies. Functional classifications produced by both models and based on the values for plasma iron turnover, marrow iron turnover, and erythron transferrin uptake were compared. Both models identified functional heterogeneity in the group with myelofibrosis and functional homogeneity within the MDS group. Each method produced comparable data on erythropoiesis. The main reason for analysing the extended plasma iron clearance is to differentiate levels of effective and ineffective erythropoiesis. The short analysis presents the practical advantages associated with a one-day study. This could be further enhanced if the level of effective erythropoiesis could be clearly defined.

Bone Marrow↗

Detection of erythroid hypoplasia in myelofibrosis using erythrokinetic studies.

The iron kinetic model described by Ricketts et al was used to study haemopoiesis in chronic myelofibrosis. The clearance of 59Fe-labelled transferrin from the plasma was analysed to quantify total, effective, and ineffective erythropoiesis, denoted by the terms marrow iron turnover (MIT), red cell iron turnover (RCIT), and per cent ineffective iron turnover (IIT%), respectively, in 12 cases of this disease. The patterns obtained were variable: values for MIT ranged from 24.4 to 510 mumol/l blood/day; those for RCIT from 0.4 to 119 mumol/l blood/day; and those for IIT% from 67 to 98%. One noteworthy feature was the presence in two cases of functional erythroid hypoplasia; these were characterised by severely reduced values for MIT (24.4 and 28 mumol/l blood/day) and RCIT (0.4 and 8 mumol/l blood/day.) A systematic study of the erythrokinetic features of myelofibrosis may indicate that erythroid hypoplasia is a more common cause of anaemia in this disease than has been previously recognised.

Anemia, Aplastic↗

New enzyme immunoassay for detecting total, type I, and type II intrinsic factor antibodies.

A method for the detection of total, type I, and type II intrinsic factor antibodies was devised. The technique comprises a two-site solid phase enzyme linked immunosorbent assay (ELISA), with human intrinsic factor conjugated with horseradish peroxidase as label and attached to polystyrene tubes as solid phase. One conjugation provides sufficient material to assay more than 10,000 patient samples. The label proved stable during the course of this evaluation and was still in use more than 12 months after preparation. When applied to 45 serum samples from cases of pernicious anaemia, intrinsic factor antibodies were shown in 30 (67%). Simplicity, high capacity, low cost and label stability, combined with relatively high clinical sensitivity make the method suitable for cost effective screening of large numbers of samples. Simple modifications to the basic assay reagents permitted type I and type II intrinsic factor antibodies to be differentiated.