PubMed Health⌕ Search

Biomedical subjects

J E de Ruijter

Publications and source records attributed to J E de Ruijter.

16 recordsLinked to original sources

Bone formation in CaP-coated and noncoated titanium fiber mesh.

The osteogenic activity of calcium phosphate (CaP)-coated and noncoated porous titanium (Ti) fiber mesh loaded with cultured syngeneic osteogenic cells after prolonged in situ culturing was compared in a syngeneic rat ectopic assay model. Rat bone marrow (RBM) cells were loaded onto the CaP-coated and noncoated Ti scaffolds using either a droplet or a suspension loading method. After loading, the RBM cells were cultured for 8 days in vitro. Thereafter, implants were subcutaneously placed in 39 syngeneic rats. The rats were euthanized and the implants retrieved at 2, 4, and 8 weeks postoperatively. Further, in the 8 week group fluorochrome bone markers were injected at 2, 4, and 6 weeks. Histological analysis demonstrated that only the CaP-coated meshes supported bone formation. The amount of newly formed bone varied between single and multiple spheres to filling a significant part of the mesh porosity. In the newly formed bone, osteocytes embedded in a mineralized matrix could be observed clearly. On the other hand, in the noncoated titanium implants, abundant deposition of calcium-containing material was seen. This deposit lacked a bonelike tissue organization. Further analysis revealed that the cell-loading method did not influence the final amount of bone formation. In CaP-coated implants the accumulation sequence of the fluorochrome markers showed that bone formation started on the mesh fibers. In conclusion, our results prove that the combination of a thin CaP coating, Ti-mesh, and RBM cells can indeed generate ectopic bone formation after prolonged in vitro culturing. No effect of the loading method was observed on the final amount of bone.

Animals↗

Osteoblast differentiation of bone marrow stromal cells cultured on silica gel and sol-gel-derived titania.

Primary cultures of osteogenic precursor cells derived from rat bone marrow stroma were performed on commercially available pure titanium discs (Ti c.p.) and surface modified Ti c.p.using a sol-gel technique (Ti sol). In separate repeated experimental runs, cell behavior and in vitro mineralization were compared with cultures on silica gel bioactive glass discs (S53P4). All substrates were incubated in simulated body fluid prior to the experiment. Overall, variable effects between experimental runs were seen. Apparently, this was due to the heterogeneous nature of the used cell population. Therefore, only careful conclusions can be made. Initial cell adhesion and growth rates between 3 and 5 days of culture--analyzed by cell numbers--were in general comparable for the two titanium substrates, while initial growth up to day 3 is suggested to be higher in Ti c.p. compared to Ti sol. Although initial cell adhesion on the S53P4 glass discs was lower than the titanium substrates, cell growth rates appeared to be higher on the silica gel compared to the two titanium substrates. Further, there were some indications that the early and late osteoblast differentiation markers, alkaline phosphatase and osteocalcin, monitored up to day 24, were elevated in Ti c.p cultures compared to Ti sol cultures. There were no differences observed in in vitro mineralization between the titanium groups. S53P4 seemed to display a substantially higher differentiating capacity for both osteogenic cell markers as well as in vitro mineralization compared to the two titanium substrates.

Alkaline Phosphatase↗

Analysis of integrin expression in U2OS cells cultured on various calcium phosphate ceramic substrates.

Earlier we observed that calcium phosphate (Ca-P)-coated implant substrates stimulated the differentiation of osteoblast-like cells compared to uncoated substrates. This suggests that this difference in osteogenic induction is due to the chemical composition of the substratum. We hypothesized that Ca-P coatings modulate integrin expression patterns, because those receptors are the sensors of the cell. Therefore, in the present study we quantitatively analyzed integrin expression of osteosarcoma cells and their proliferation behavior on various well-defined Ca-P substrates. For this study we used the osteosarcoma cell line U2OS. Five groups of substrates were used: thermanox (Th), uncoated titanium (Ti), dense sintered hydroxyapatite (HA), and two Ca-P-coated titanium discs (TiHA-O% and TiHA-5%). At day 5, cell numbers were significantly lower (p < 0.05) for both types of Ca-P-coated titanium substrates compared to the other substrates. There were no significant differences between HA and uncoated titanium. From day 5 to 8, accumulated cell number was ranking highest to lowest HA > Th = Ti > TiHA-0% > TiHA-5%. Integrin expression at day 5 and day 8 of incubation was analyzed by flow cytometry for integrin subunits beta 1, alpha 3, alpha 4, alpha 5, alpha 6, and alpha v. Fluorescence-activated cell sorting (FACS) analysis showed that the cells express high levels of beta 1, low levels of alpha 4, alpha 5, and alpha 6, and moderate levels of alpha 3 and alpha v integrin subunits on the various biomaterial substrates. Minor differences in integrin expression between the various substrates were seen. Therefore, the observed differences in proliferation between the coatings may reside in modulating the functional properties of integrins.

Alkaline Phosphatase↗

The effect of poly-L-lactic acid with parallel surface micro groove on osteoblast-like cells in vitro.

In this study we evaluated the behavior of rat bone marrow (RBM) cells on microgrooved poly-L-lactic acid (PLA) and polystyrene (PS) surfaces. The applied groove depth was 0.5, 1.0 or 1.5 microns, with a groove and ridge width of 1, 2, 5 or 10 microns. Scanning electron microscopical examination showed that a collagen-rich mineralized layer of extracellular matrix (ECM) was deposited. Alignment of the cells and matrix to the surface grooves was observed as described before. Quantitative evaluation, using a tetracycline labeling assay, revealed that more mineralized ECM was formed on the PLA than on the PS. Further, PLA surfaces with a groove depth of 1.0 micron and groove widths of 1 and 2 microns induced most mineralized ECM. Finally, alkaline phosphatase activity was also higher on most microgrooved PLA surfaces, compared with the other materials. On the basis of these observations, we concluded that microtextured surfaces are able to influence the differentiation of osteoblast-like cells and the deposition of mineralized matrix. Probably, this phenomenon can be used to increase the bone regeneration around oral implants.

Alkaline Phosphatase↗

Soft tissue and epithelial models.

The applicability of a biomaterial for the manufacturing of oral implants is determined by its physicochemical and geometric surface properties. Research, therefore, is concerned with the cellular reactions that occur when an implant material comes into contact with body tissues. For permucosal oral implants, this involves both the reaction of bone and gingival cells. In vitro cell culturing--including the use of various analytical techniques like light microscopy, scanning and transmission electron microscopy, confocal laser scanning microscopy, and digital image analysis--is a good tool whereby investigators can obtain more insight into the relevant components of implant-tissue adhesion. In the current overview, the role of cell models in oral implant research is discussed, specifically with reference to responses of epithelial cells and fibroblasts.

Alveolar Process↗

Interfacial phenomena: an in vitro study of the effect of calcium phosphate (Ca-P) ceramic on bone formation.

In previous studies we developed a RF magnetron sputter technique for the production of thin Ca-P coatings. With this technique coatings can be produced that vary in Ca/P ratio as well as in structural appearance. The aim of this investigation was to obtain more understanding of the biological behavior of these coatings by way of in vitro experiments. The effect of noncoated titanium (Ti) and three different Ca-P-sputtered surfaces on the proliferation and differentiation (morphology and matrix production) of osteoblast-like cells was studied. Proliferation was determined using counting procedures; morphology was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Fluorescent markers and energy-dispersive X-ray microanalysis (EDX) were used to obtain quantitative and compositional information about the resultant calcified extracellular matrix (ECM). Results demonstrated that proliferation of the osteoblast-like cells was significantly (p < 0.05) higher on noncoated than on Ca-P-coated samples. On the other hand, more mineralized ECM was formed on the coated surfaces. In addition, TEM confirmed that the cells on the coated substrates were surrounded by ECM with collagen fibers embedded in crystallized, needle-shaped structures. On the basis of these findings, we concluded that: (1) the investigated Ca-P sputter coatings possess the capacity to activate the differentiation and expression of osteogenic cells, and (2) bone formation proceeds faster on Ca-P surfaces than on Ti substrates. Further, this bone-inductive effect appeared to be dependent on the Ca-P ratio of the deposited coatings.

Animals↗

Orientation of ECM protein deposition, fibroblast cytoskeleton, and attachment complex components on silicone microgrooved surfaces.

The microfilaments and vinculin-containing attachment complexes of rat dermal fibroblasts (RDF) incubated on microtextured surfaces were investigated with confocal laser scanning microscopy (CLSM) and digital image analysis (DIA). In addition, depositions of bovine and endogenous fibronectin and vitronectin were studied. Smooth and microtextured silicone substrata were produced that possessed parallel surface grooves with a groove and ridge width of 2.0, 5.0, and 10.0 microns. The groove depth was approximately 0.5 micron. CLSM and DIA make it possible to visualize and analyze intracellular and extracellular proteins and the underlying surface simultaneously. It was observed that the microfilaments and vinculin aggregates of the RDFs on the 2.0 microns grooved substrata were oriented along the surface grooves after 1, 3, 5, and 7 days of incubation while these proteins were significantly less oriented on the 5.0 and 10.0 microns grooved surfaces. Vinculin was located mainly on the surface ridges on all textured surfaces. In contrast, bovine and endogenous fibronectin and vitronectin were oriented along the surface grooves on all textured surfaces. These proteins did not seem to be hindered by the surface grooves since many groove-spanning filaments were found on all the microgrooved surfaces. In conclusion, it can be said that microtextured surfaces influence the orientation of intracellular and extracellular proteins. Although results corroborate three earlier published hypotheses, they do not justify a specific choice of any one of these hypotheses.

Animals↗

The effect of a subcutaneous silicone rubber implant with shallow surface microgrooves on the surrounding tissues in rabbits.

It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, and 84 days. The textured implants possessed parallel surface microgrooves and ridges with a width of 2.0, 5.0, and 10.0 microns. All grooves had a depth of approximately 0.5 microns. SEM observation showed fibroblasts, erythrocytes, lymphocytes, macrophages, fibrin, and collagen on all implant surfaces after 3 and 7 days. After 42 and 84 days only little collagen, a small number of fibroblasts, but no inflammatory cells were seen on the implant surfaces. The fibroblasts were not oriented along the surface grooves on all textured surfaces. Three-dimensional reconstruction of CLSM images and LM images showed no significant differences between the thickness of the capsules surrounding the smooth and those surrounding the microgrooved implants. In contrast LM did show a significantly lower number of inflammatory cells and a significantly higher number of blood vessels in the capsules surrounding the microgrooved implants. Differences between the 2.0, 5.0, and 10.0 microns grooved implants were not detected. Our results concerning the capsule thickness suggest that the depth of our grooves was not sufficient to facilitate mechanical interlocking, but the cause for the observed differences in inflammatory response and number of blood vessels remains unclear.

Animals↗

Wound healing phenomena in titanium fibre mesh: the influence of the length of implantation.

In previous experiments a new type of percutaneous device for implantation in soft tissue was designed, containing a sintered titanium fibre mesh. The devices are inserted by a so-called "two-phase' surgical technique with an intervening healing period of 3 months between insertion of the subcutaneous and percutaneous parts. From a clinical point of view, this time interval is too long. The aim of this study was to investigate whether it was possible to reduce the intervening healing period. The implants were inserted in the backs of nine goats. In each goat, six implants were placed with intervals of 1 week. Consequently, at the end of the experiment, in each goat six implants were present with implantation periods ranging from 1 to 6 weeks. After 6 weeks, the animals were killed and the implants with surrounding tissue were processed histologically. Analysis demonstrated that during the first 2 weeks an inflammatory response was present. Thereafter, no difference in tissue response was found between the various implantation periods. In conclusion, the experiment suggests that for titanium mesh percutaneous devices a 3-week healing period is sufficient between the installation of the subcutaneous and percutaneous parts.

Animals↗

Quantitative analysis of fibroblast morphology on microgrooved surfaces with various groove and ridge dimensions.

Fibroblasts have been shown to respond to substratum surface roughness. The change in cell size, shape and orientation of rat dermal fibroblasts (RDF) was therefore studied using smooth and microtextured silicone rubber substrata. The microtextured substrata possessed parallel surface microgrooves that ranged in width from 1.0 to 10.0 microns, and were separated by ridges of 1.0 to 10.0 microns. The grooves were either 0.45 or 1.00 microns deep. Prior to incubation, the substrata were cleaned and given a radio frequency glow discharge treatment. After surface evaluation with scanning electron microscopy and confocal laser scanning microscopy, RDF were incubated on these substrata for 5 days. During this period of incubation, the RDF were photographed on days 1, 2, 3, 4, and 5, using phase contrast microscopy. Digital image analysis of these images revealed that on surfaces with a ridge width < or = 4.0 microns, cells were highly orientated (< 10 degrees) and elongated along the surface grooves. Protrusions contacting the ridges specifically could be seen. If the ridge width was larger than 4.0 microns, cellular orientation was random (approximately 45 degrees) and the shape of the RDF became more circular. Furthermore, results showed that the ridge width is the most important parameter, since varying the groove width and groove depth did not affect the RDF size, shape, nor the angle of cellular orientation.

Animals↗

Tissue reaction to Dacron velour and titanium fibre mesh used for anchorage of percutaneous devices.

Dacron velour is often used to anchor a percutaneous device, like the catheter used in peritoneal dialysis. However, exit-site infections complicate this method of dialysis and are supposed to be related to the design of the catheter. In animal experiments, a percutaneous device provided with a titanium fibre mesh to anchor the implant was not affected by infectious complications. The purpose of this study was to compare the differences in soft tissue reaction to Dacron velour and titanium fibre mesh under the same experimental conditions. Therefore, we placed implants, provided with either Dacron or titanium mesh, subcutaneously in the dorsum of goats. The implants were left in situ for 4 months. Histological and histomorphological evaluations were performed. It was found that the soft tissue response inside the Dacron was mainly inflammatory, while the titanium mesh evoked good biocompatible behaviour. We concluded that the limited fibrous tissue ingrowth into the Dacron cuff has to be the reason for the observed high failure incidence of a percutaneous device.

Administration, Cutaneous↗

Quantitative analysis of cell proliferation and orientation on substrata with uniform parallel surface micro-grooves.

In order to quantify the effect of the substrata surface topography on cellular behaviour, planar and micro-textured silicon substrata were produced and made suitable for cell culture by radio frequency glow discharge treatment. These substrata possessed parallel surface grooves with a groove and ridge width of 2.0 (SilD02), 5.0 (SilD05) and 10 microns (SilD10). Groove depth was approximately 0.5 micron. Rat dermal fibroblasts (RDFs) were cultured on these substrata and a tissue culture polystyrene control surface for 1, 2, 3, 5 and 7 days. After incubation the cell proliferation was quantified with a Coulter Counter, and RDF size, shape and orientation with digital image analysis. Cell counts proved that neither the presence of the surface grooves nor the dimension of these grooves had an effect on the cell proliferation. However, RDFs on SilD02, and to a lesser extent on SilD05 substrata, were elongated and aligned parallel to the surface grooves. Orientation of the RDFs on SilD10 substrata proved to be almost comparable to the SilD00 substrata. Finally, it was observed that the cells on the micro-textured substrata were capable of spanning the surface grooves.

Animals↗

Effect of parallel surface microgrooves and surface energy on cell growth.

To evaluate the effect of surface treatment and surface microtexture on cellular behavior, smooth and microtextured silicone substrata were produced. The microtextured substrata possessed parallel surface grooves with a width and spacing of 2.0 (SilD02), 5.0 (SilD05), and 10 microns (SilD10). The groove depth was approximately 0.5 microns. Subsequently, these substrata were either left untreated (NT) or treated by ultraviolet irradiation (UV), radiofrequency glow discharge treatment (RFGD), or both (UVRFGD). After characterization of the substrata, rat dermal fibroblasts (RDF) were cultured on the UV, RFGD, and UVRFGD treated surfaces for 1, 3, 5, and 7 days. Comparison between the NT and UV substrata revealed that UV treatment did not influence the contact angles and surface energies of surfaces with a similar surface topography. However, the contact angles of the RFGD and UVRFGD substrata were significantly smaller than those of the UV and NT substrata. The dimension of the surface microevents did not influence the wettability characteristics. Cell culture experiments revealed that RDF cell growth on UV-treated surfaces was lower than on the RFGD and UVRFGD substrata. SEM examination demonstrated that the parallel surface grooves on the SilD02 and SilD05 substrata were able to induce stronger cell orientation and alignment than the events on SilD10 surfaces. By combining all of our findings, the most important conclusion was that physicochemical parameters such as wettability and surface free energy influence cell growth but play no measurable role in the shape and orientation of cells on microtextured surfaces.

Animals↗

In vitro proton magnetic resonance spectroscopy of four human prostate cancer cell lines.

There is accumulating evidence that some biochemical pathways observable by magnetic resonance spectroscopy, e.g., citrate acid and phospholipid metabolism, are altered in human prostate cancer. Four well-established human prostate cancer cell lines were therefore studied with magnetic resonance spectroscopy to compare differences in metabolic content with tumor biological behavior. Herein we demonstrate that, although each cell line has its own metabolic profile, relative creatine and citrate levels can be used to discriminate the androgen-dependent LNCaP cell line from the androgen-independent DU-145, TSU, and PC-3 cell lines.

Androgens↗

Histological evaluation of a biodegradable Polyactive/hydroxyapatite membrane.

Guided tissue regeneration (GTR) is a technique which is used for the treatment of bone defects associated with periodontal disease or enossal dental implants. In most experimental studies on GTR, non-degradable membranes are used. A drawback inherent to such devices is that at the end or in the course of the wound healing they have to be removed. Therefore, the aim of the present study was to investigate a new biodegradable membrane material for use in GTR, which also has excellent mechanical properties and is biocompatible. The material is a composite consisting of poly(ethyleneglycol terephthalate) and poly(butylene terephthalate) segmented copolymer (PEG/PBT), which for the experiments was used in pure form and also mixed with hydroxyapatite (HA) grains. Subcutaneous and subgingival implantation studies in goats were performed to determine the biocompatibility and biodegradability characteristics of several of these materials. Differences between materials were introduced in the production process, PEG/PBT ratio, material thickness and presence of HA. Implantation periods were 3, 6 and 12 wk. The histological results indicated that all investigated materials were biocompatible with the surrounding tissue. Degradation of the membranes was attended by a mild cellular reaction. The degradation process was mainly influenced by the PEG/PBT ratio. A higher PBT content resulted in a decreased degradation.

Animals↗

Titanium fiber mesh anchorage for percutaneous devices applicable for peritoneal dialysis.

In previous experiments a new type of percutaneous device for implantation in soft tissue was designed. The subcutaneous component of the new device consists of a sintered titanium fiber web. The percutaneous devices are inserted by a so-called "two-phase" surgical technique with an intervening healing period of 3 months between the insertion of the subcutaneous flange and the placement of the percutaneous part. From a clinical point of view, this time interval is too long. Therefore, the aim of this study was to investigate a possible reduction of the intervening healing period. The implants were inserted in the backs of 18 rabbits. In each rabbit, six implants were placed with intervals of 1 week. Consequently, at the end of the experiment, in each rabbit six implants were present with implantation periods ranging from 5-10 weeks. After 10 weeks, the animals were sacrificed and the implants with their surrounding tissues were processed histologically. Light microscopic and histomorphometric analysis demonstrated that there was no difference in tissue response between the various implantation periods. Furthermore, it was found that the fiber mesh material showed good biocompatible behavior. In conclusion, the experiment has demonstrated that for titanium mesh percutaneous devices a 5-week healing period is sufficient between the installation of the subcutaneous and percutaneous parts.

Animals↗