PubMed Health⌕ Search

Biomedical subjects

J Earnhart

Publications and source records attributed to J Earnhart.

3 recordsLinked to original sources

Simulation of Compton camera imaging with a specific purpose Monte Carlo code

A specific purpose Monte Carlo model that treats the physical processes of image formation in Compton cameras is presented. Features of the model include: detailed Compton scattering physics, including incoherent scattering functions and Doppler broadening; multiple scattering; and peak detector response functions. Calculation efficiency is enhanced by making every history result in a partial success through the extensive use of pathway sampling variance reduction techniques. The code was benchmarked to data obtained from a prototype camera using CdZnTe and silicon room-temperature detector technology. Reasons for observed discrepancies between the simulation model and experiments are explored. Implicit assumptions, related to our implementation of pathway sampling, appear to be the greatest source of error.

Journal Article↗

A comparison of different intensity modulation treatment techniques for tangential breast irradiation.

PURPOSE: Several intensity modulation (IM) treatment techniques for tangential breast irradiation were evaluated in terms of dose uniformity in the treated breast volume, contralateral breast dose, and treatment irradiation time. METHODS AND MATERIALS: Contralateral breast dose was measured via TLD chips, and the dose uniformity was calculated on two anthropomorphic phantoms. IM was applied to all beams or to the lateral-medial (LM) beam only. The techniques evaluated include (a) IM via "step & shoot" multileaf collimator (MLC), (b) IM via intensity modulator (compensator), (c) virtual wedge, and (d) physical wedge. A dose optimization algorithm was used for the first two techniques. RESULTS: Collimator-generated IM techniques (MLC-IM and the virtual wedge) produced 50% (average) less contralateral breast dose than the conventional two-wedge technique. When the compensator or the physical wedge was used, contralateral breast dose was reduced 30% (average) by leaving the ML beam open. CONCLUSION: The treatments generated by dose optimization algorithm and delivered via the compensator and MLC techniques offered superior dose uniformity. Single-beam IM techniques in general use less irradiation time without significant degradation of dose uniformity. The MLC-IM technique in this study required the longest treatment irradiation time, while the virtual wedge and compensator IM techniques required the least.

Algorithms↗

Benchmark test cases for evaluation of computer-based methods for detection of setup errors: realistic digitally reconstructed electronic portal images with known setup errors.

PURPOSE: The purpose of this investigation was to develop methods and software for computing realistic digitally reconstructed electronic portal images with known setup errors for use as benchmark test cases for evaluation and intercomparison of computer-based methods for image matching and detecting setup errors in electronic portal images. METHODS AND MATERIALS: An existing software tool for computing digitally reconstructed radiographs was modified to compute simulated megavoltage images. An interface was added to allow the user to specify which setup parameter(s) will contain computer-induced random and systematic errors in a reference beam created during virtual simulation. Other software features include options for adding random and structured noise, Gaussian blurring to simulate geometric unsharpness, histogram matching with a "typical" electronic portal image, specifying individual preferences for the appearance of the "gold standard" image, and specifying the number of images generated. The visible male computed tomography data set from the National Library of Medicine was used as the planning image. RESULTS: Digitally reconstructed electronic portal images with known setup errors have been generated and used to evaluate our methods for automatic image matching and error detection. Any number of different sets of test cases can be generated to investigate setup errors involving selected setup parameters and anatomic volumes. This approach has proved to be invaluable for determination of error detection sensitivity under ideal (rigid body) conditions and for guiding further development of image matching and error detection methods. Example images have been successfully exported for similar use at other sites. CONCLUSIONS: Because absolute truth is known, digitally reconstructed electronic portal images with known setup errors are well suited for evaluation of computer-aided image matching and error detection methods. High-quality planning images, such as the visible human CT scans from the National Library of Medicine, are essential for producing realistic images. Sets of test cases with systematic and random errors in selected setup parameters and anatomic volumes are suitable for use as standard benchmarks by the radiotherapy community. In addition to serving as an aid to research and development, benchmark images may also be useful for evaluation of commercial systems and as part of a quality assurance program for clinical systems. Test cases and software are available upon request.

Computer Simulation↗