On the signal response of various pesticides in electrospray and atmospheric pressure chemical ionization depending on the flow-rate of eluent applied in liquid chromatography-tandem mass spectrometry.

The API-MS signal response of several pesticides (atrazine, simazine, isoproturon, diuron, chlorfenvinphos, chlorpyrifos, alachlor, trifluralin) depending on the flow-rate of eluent entering the MS interface was investigated. The investigations were based on API-MS-MS analyses of standard pesticide mixtures in the flow injection mode (FIA) at systematically varied eluent flow-rates using both an ESI interface (Turboionspray) and a heated nebulizer type APCI source. In the result, the individual compounds included in this study showed significant differences in their signal response behaviour depending on the flow-rate of eluent applied. The most hydrophobic compounds among the investigated pesticides (chlorpyrifos and trifluralin) showed drastic losses of sensitivity with increasing eluent flow-rate in both ESI and APCI, while more hydrophilic compounds like atrazine, simazine and isoproturon showed the expected signal response (concentration-sensitive in ESI, mass-flow-sensitive in APCI) at least within a certain range of flow-rates (200-600 microl/min in ESI, 200-2000 microl/min in APCI). These findings lead to the conclusion that application of a programmed HPLC eluent flow-rate may be advantageous to achieve maximum sensitivity of API-MS detection for all pesticides of interest. This is exemplified by the implementation of a flow gradient into an online SPE-HPLC-APCI-MS/MS method for improved analysis of pesticides in drinking water.

Atmospheric Pressure↗

Application of spectral libraries for high-performance liquid chromatography-atmospheric pressure ionisation mass spectrometry to the analysis of pesticide and explosive residues in environmental samples.

The coupling of high-performance liquid chromatography (HPLC) and atmospheric pressure ionisation mass spectrometry (API-MS) seems to be the method of choice if good separation and selective detection of semi-volatile, thermolabile, and polar substances is required. Libraries of mass spectra will make the identification of unknown substances in complex environmental samples easier and more user-friendly. Unfortunately, existing GC-MS libraries are not applicable to HPLC-API-MS analysis. Thus, new and extensive mass spectral libraries were constructed. Several investigations of chromatographic (composition and salt concentration of the eluent) as well as mass spectrometric (orifice voltage) parameters and a few applications of real environmental samples are used to discuss the possibilities and limits of these libraries.

Atmospheric Pressure↗

Programmed temperature vaporiser-based injection in capillary gas chromatography.

The application of programmed temperature vaporisation (PTV) in capillary gas chromatographic analysis is reviewed. The development of the different strategies as well as the state of the art are described. As the analytes are normally enriched in the PTV insert, the quoted papers are subdivided depending on whether the enrichment was carried out from organic solvents, from water or from gaseous media. Furthermore, the possibilities of PTVs for on-line coupling with sample preparation methods or other separation techniques and their use as thermoreactors are mentioned.

Chromatography, Gas↗