PubMed Health⌕ Search

Biomedical subjects

J Emneus

Publications and source records attributed to J Emneus.

4 recordsLinked to original sources

Immunologic trapping in supported liquid membrane extraction

To obtain a high degree of selectivity in sample preparation, supported liquid membrane (SLM) extraction was combined with immunologic recognition. The SLM employs a hydrophobic polymer for supporting the immobilization of an organic solvent, thus forming a nonporous membrane. Said membrane separates the aqueous sample on one side (donor) from a receiving aqueous phase on the other (acceptor). The extraction involves the partitioning of neutral compounds between the sample solution, continuously pumped alongside the membrane, and the membrane. From the membrane, reextraction takes place into a second aqueous phase containing antibodies specific for the target compound(s). Hence, there is a formation of an antibody-antigen complex at the heart of the sample preparation (ImmunoSLM). When the immunocomplex forms, the antigen can no longer redissolve in the organic membrane, thus being trapped in the acceptor. Consequently, the concentration gradient of free antigen over the membrane is ideally unaffected, this being the driving force for the process. With a surplus of antibody, the concentration of analyte in the receiving phase will easily exceed the initial sample concentration. In this work, the so formed immunocomplex was quantified on-line, using a fluorescein flow immunoassay in a sequential injection analysis (SIA) setup. The outlined ImmunoSLM-SIA scheme was successfully applied for the extraction of 4-nitrophenol from spiked water solutions as well as from a spiked wastewater sample, indicating that the immunoextraction can be suitable when dealing with difficult matrixes.

Journal Article↗

Inter-laboratory comparison of liquid chromatographic techniques and enzyme-linked immunosorbent assay for the determination of surfactants in wastewaters.

Seven laboratories participated in an inter-laboratory comparison exercise within the framework of the PRISTINE, SANDRINE and INEXsPORT European Union Projects. Solid-phase extraction (SPE) methodologies were used for the extraction of target analytes from wastewaters. The analytical strategies were based on liquid chromatography (LC) coupled to mass spectrometric (MS) or to fluorescent (FL) detection in all cases with the exception of one laboratory using a test-tube enzyme-linked immunosorbent assay kit. Samples were spiked with the surfactants nonylphenolpolyglycol ether, coconut diethanolamide, linear alkylbenzene sulfonate, nonylphenolpolyglycol ether sulfate, alkylpolyglycol ether and secondary alkane sulfonate. After enrichment on previously conditioned SPE cartridges, the SPE cartridges were distributed among the participating laboratories without the information about the amount of spiked surfactants. In addition, SPE cartridges loaded with a real-world environmental sample containing a tannery wastewater were also analyzed. The results of the programme showed that SPE followed by LC-MS techniques are reliable for the surfactants determination at submicrogram to microgram per liter levels in wastewaters. Inter-laboratory precision values were calculated as the reproducibility relative standard deviation (RSD(R)) which was determined from the reproducibility standard deviation (sR) and the average concentration at a particular concentration level. When data from all laboratories were pooled, the RSD(R) values ranged from 5.1 to 28.3% for the determination of target analytes. The most accurate result corresponded to that given for linear alkylbenzene sulfonates. Taking into account that different methodologies were used (including non-chromatographic techniques) and the complexity of the samples analyzed, it can be considered that acceptable reproducibility values were obtained in this inter-laboratory study.

Chromatography, Liquid↗

[Comamonas testosteroni strain TI as a potential base for a microbial sensor detecting surfactants].

Strain Comamonas testosteroni TI, capable of degrading the nonionic surfactant (NIS) nonylphenolethoxylate (OP-10), was used for constructing a pilot cellular biosensor. The lower NIS detection limit for the biosensor was 0.25 mg/l. We studied the substrate specificity of the biosensor with respect to a wide range of organic compounds: surfactants, polyaromatic compounds (PAC), carbohydrates, alcohols, etc. It was shown that the biosensor based on Comamonas testosteroni TI did not respond to glucose, which was an advantage over the formerly described biosensor based on Pseudomonas rathonis T. The amplitude of the sensor response remained stable for 10 days.

Biosensing Techniques↗