PubMed Health⌕ Search

Biomedical subjects

J F Esquivel-Upshaw

Publications and source records attributed to J F Esquivel-Upshaw.

3 recordsLinked to original sources

Ceramic design concepts based on stress distribution analysis.

This article discusses general design concepts involved in fabricating ceramic and metal-ceramic restorations based on scientific stress distribution data. These include the effects of ceramic layer thickness, modulus of elasticity of supporting substrates, direction of applied loads, intraoral stress, and crown geometry on the susceptibility of certain restoration designs to fracture.

Ceramics↗

Resistance to staining, flexural strength, and chemical solubility of core porcelains for all-ceramic crowns.

PURPOSE: The increased demand for tooth-colored restorations has prompted the use of ceramics in areas that are subject to masticatory stresses. To maximize the strength of these restorations, manufacturers and clinicians advocate placement of core materials in lieu of veneering materials in areas that are more susceptible to fracture. The objectives of this study were to determine the: resistance to staining of three core porcelains used for all-ceramic restorations, Procera, IPS Empress, and In-Ceram, through the use of colorimetry and visual observation; flexural strength of these porcelains under a three-point bend test; and chemical solubility in a controlled environment. MATERIALS AND METHODS: L*a*b* values were obtained for each specimen before and after immersion in a saturated solution of methylene blue in ethanol for 24 hours. Visual observation was also performed to ascertain color differences before and after staining. A three-point bend test was used to determine flexural strength. A reflux-condenser type, three-piece extraction apparatus was used with 4% acetic acid solution for 16 hours to determine solubility. Each sample was weighed before and after the reflux procedure to ascertain percentage weight loss. RESULTS: The mean delta E obtained for IPS Empress was 14.5; In-Ceram was 9.2, and Procera was 9.0. Flexural strength obtained for IPS Empress, In-Ceram, and Procera was 176.9 MPa, 323.4 MPa, and 464.3 MPa, respectively. Weight loss of IPS Empress, In-Ceram, and Procera was 0.056%, 0.734%, and 0.003%, respectively. CONCLUSION: IPS Empress showed the least resistance to staining. IPS Empress had the lowest flexural strength, while Procera had the highest. In-Ceram demonstrated the highest chemical solubility.

Acetates↗

Fracture resistance of all-ceramic and metal-ceramic inlays.

PURPOSE: Metal-ceramic inlay designs were developed to determine if the esthetic qualities of all-ceramic inlays could be duplicated and at the same time improve their strength and stability. The objectives of this study were to: (1) compare the fracture resistance of metal-ceramic inlays with that of all-ceramic inlays; (2) determine the correlation between the degree of preparation taper and fracture resistance; and (3) determine the correlation between marginal gap width and fracture resistance. MATERIALS AND METHODS: Inlay preparations were made on 60 Dentoform teeth, with 30 teeth allocated for metal-ceramic inlays and 30 teeth for all-ceramic inlays. Each group was further subdivided into 5-, 10-, and 20-degree taper preparations. Metal-ceramic inlays were fabricated using Goldtech Bio 2000 metal and Ceramco porcelain extending to the margin, while all-ceramic inlays were made from Empress II ceramic. Marginal gap widths were measured at six critical areas after fabrication. The load at failure was measured using an Instron Universal Testing Machine. RESULTS: The mean fracture load for all-ceramic inlays and metal-ceramic inlays at 5, 10, and 20 degrees was 70+/-40 N, 48+/-37 N, 33+/-7 N, and 40+/-23 N, 29+/-22 N, and 14+/-4 N, respectively. The mean gap width was 105 microm and 126 microm for all-ceramic and metal-ceramic inlays, respectively. CONCLUSION: The mean fracture load for Empress inlays was significantly higher than that for metal-ceramic inlays. Inlays with a 5-degree taper were significantly more fracture resistant than those with a 20-degree taper. There was no relation between marginal gap width and fracture resistance.

Aluminum Silicates↗