Telepresence interface with applications to microsurgery and surgical simulation.

To address the needs for performing microsurgical procedures, the SRI telepresence surgery workstation has been combined with a pair of micromanipulator arms. The prototype microsurgery system has been tested with ex-vivo tasks similar to those required for surgical procedures, such as cutting, grasping, suturing, and knot tying. Initial animal testing has been done on a rat model in which end-to-end anastomosis of the femoral artery (approximately 1 millimeter in diameter) was completed with ten rats, and 100% patency was obtained. To address the needs of surgical training, SRI has begun to develop a system that uses a 6-DOF telepresence workstation. A computer-generated stereo image is reflected in a mirror and appears to be superimposed on the surgeon's hands, creating an immersive and realistic environment. Tools held in the surgeon's hands are connected to left- and right-hand manipulators that both continuously measure tool position/orientation and apply force/torque to the tools. Furthermore, the visual image and tool locations are registered, so that the user perceives that he or she is looking at and moving the simulated tools in the visual image.

Animals↗

In vivo assessment of breast muscle, abdominal fat and total fat volume in meat-type chickens by magnetic resonance imaging.

Measurements were performed on commercial broiler chickens by magnetic resonance imaging (MRI) tomography. A total of 72 chickens were scanned at the age of 6, 7, 8, 10, 16 and 20 weeks. MRI scans based on spin echo sequence were taken in the three orthogonal planes. The volume of the pectoral muscles increased from 259 cm3 to 1035 cm3 in males and from 250 cm3 to 875 cm3 in females between 6 and 20 weeks of age. Abdominal fat volume increased from 18.9 cm3 to 153.2 cm3 in males and from 19.3 cm3 to 267.0 cm3 in females between 7 and 20 weeks of age. Total body fat volume increased from 129 cm3 to 557 cm3 in males and from 171 cm3 to 1321 cm3 in females between 6 and 20 weeks of age. The correlation coefficients between the total volume of fat pixels and the amount of abdominal fat determined in the coronal plane by MRI were 0.85 and 0.95 in the male and female sex, respectively. Changes found in the pectoral muscles (mm. pectorales) as well as in total and abdominal fat volume were in close agreement with dissection data obtained at the slaughterhouse and with laboratory data based on the measurement of total body chemical composition in both sexes. This MRI method can be a good complement to computed tomography (CT) scanning in the transversal plane.

Adipocytes↗

Ultrasound tissue characterization of breast biopsy specimens: expanded study.

Tissue classification by examining sets of ultrasound parameters is an elusive goal. We report analysis of measurements of ultrasound speed, attenuation and backscatter in the range 3 to 8 MHz in breast tissues at 37 C. Statistical discriminant analysis and neural net analysis were employed. Data were acquired from 24 biopsy and 7 mastectomy specimens. Best separation of the classes normal, benign, and malignant occurred in the 18 cases where two tissue classes were present in the same specimen and parameters were corrected for within-patient mean; then 85-90% of cases in test sets were correctly classified. Most errors comprised misclassified benign cases. The neural net was comparable to discriminant analysis and slightly superior in separating normal and malignant classes.

Breast↗

Advanced telepresence surgery system development.

SRI International is currently developing a prototype remote telepresence surgery system, for the Advanced Research Projects Agency (ARPA), that will bring life-saving surgical care to wounded soldiers in the zone of combat. Remote surgery also has potentially important applications in civilian medicine. In addition, telepresence will find wide medical use in local surgery, in endoscopic, laparoscopic, and microsurgery applications. Key elements of the telepresence technology now being developed for ARPA, including the telepresence surgeon's workstation (TSW) and associated servo control systems, will have direct application to these areas of minimally invasive surgery. The TSW technology will also find use in surgical training, where it will provide an immersive visual and haptic interface for interaction with computer-based anatomical models. In this paper, we discuss our ongoing development of the MEDFAST telesurgery system, focusing on the TSW man-machine interface and its associated servo control electronics.

Computer Systems↗

Restriction endonuclease analysis of herpesviruses isolated from two peninsular bighorn sheep (Ovis canadensis cremnobates).

In 1989, herpesviruses were isolated from nasal swabs taken from two peninsular bighorn sheep (Ovis canadensis cremnobates) in the Anza-Borrego Desert State Park, San Diego County, California (USA). Using restriction endonuclease analysis (REA) with Pst1 enzyme, each isolate was found to be similar to the Cooper strain of infectious bovine rhinotracheitis virus (IBRV). The REA patterns of the two herpesviruses from bighorn sheep were typical of either field strains or vaccine strains of IBRV commonly associated with cattle in the USA.

Animals↗

Reflex transmission imaging improves ultrasonic visualization and characterization of calculi for lithotripsy applications.

A new ultrasound technique combining reflex transmission imaging (RTI) and integrated reflection C-scan (IRCS) imaging is being developed to enhance visualization of calculi for lithotripsy applications. Reflex transmission imaging/integrated reflection C-scan ultrasound produces orthographic images (similar to flat-field x-ray films) that improve the delineation of stone from soft tissue. Integrated reflection C-scan imaging is based on reflectivity while RTI is based on transmissivity of structures (stones) in the focal plane. Quantitative measurements of reflectance (IRCS) and attenuation (RTI) show potential for stone characterization and assessment of the degree of fragmentation. In vitro and in vivo images are presented.

Cholelithiasis↗

Ultrasound tissue characterization of breast biopsy specimens.

Results of measurements of ultrasound speed and absorption coefficients in the range 3 to 8 MHz in breast tissues at 37 C are reported and analyzed in attempts to identify a set of ultrasound parameters capable of discriminating normal, benign, and malignant tissues. We analyzed 118 tissue regions, comprising 47 normal, 55 benign, and 16 malignant by straight-line fitting of frequency dependence of attenuation. Data for ten additional regions, for a total of 128, became available and were added to the cohort when we subsequently fitted quadratic curves. Sound speed consistently emerged as the variable with greatest discriminating power, particularly for separating normal from benign and malignant tissue. Great difficulty was encountered in discriminating benign from malignant, even when the jackknife technique was used. More success was found with classification and regression trees (CART), although results were sensitive to assigned misclassification costs. Best results from straight-line fits were obtained when discriminating malignant from combined normal/benign data after randomly assigning 75 percent of the data to the learning set and 25 percent to the test set. Then, 23 out of 25 normal/benign and 4 out of 4 malignant cases in the test set were correctly classified. With quadratic fitting, best results were obtained in the three-class case--the false positive rate for malignancy was reduced to zero in the learning (0/31) and test (0/10) sets. Nevertheless, the false negative rate increased to 13 out of 31 (42 percent) in the learning set, while attaining zero (0/4) in the test set.

Adenofibroma↗

Apparatus for ultrasound tissue characterization of excised specimens.

Apparatus is described for measurement of sound speed and ultrasound attenuation coefficients by the substitution technique in the frequency range 3 to 8 MHz. Phase-cancellation artifacts leading to overestimation of attenuation coefficients are avoided by use of an acoustoelectric transducer. Specimens confined by polystyrene windows can be interrogated by focused ultrasound beams at selected locations spaced on a grid of 3 x 3 mm voxels. Pulse time of flight is measured with an accuracy of 30 ns, yielding sound speeds accurate to +/- 6.7 m/s, for samples 10 mm thick. Uncertainties in measured insertion losses range from 0.1 dB in low-loss (10 dB) specimens to 0.5 dB in high-loss (25 dB) specimens.