PubMed HealthSearch

Biomedical subjects

J F Keane

Publications and source records attributed to J F Keane.

At least 19 recordsLinked to original sources

Transcatheter umbrella closure of valvular and paravalvular leaks.

OBJECTIVES: Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. BACKGROUND: The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. METHODS: Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. RESULTS: Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the umbrella was found securely in place across the paraaortic defect) and two patients are clinically well at home after 21 and 32 months, respectively. Of the four patients with closure of a valvular leak, one patient remains well at home 50 months later, one patient died at operation for associated defects and two patients had additional successful surgical treatment and remain well 29 months after device placement. CONCLUSIONS: Transcatheter umbrella closure appears to be a reasonable alternative for closure of a valvular or paravalvular leak in patients who are poor operative candidates.

Aortic Valve

Transcatheter closure of coronary artery fistulas.

Transcatheter closure of a coronary artery fistula was undertaken in nine patients. There were three fistulas from the left circumflex coronary artery to the coronary sinus, three from the left anterior descending coronary artery to the right ventricular apex, two from the right coronary artery to the superior vena cava/right atrial junction and one fistula from the left circumflex artery to the pulmonary artery. The fistula was closed with Gianturco coils in six patients, a double-umbrella device in two and a combination of an umbrella and coils in one patient. All fistulas are completely occluded. Complications consisted of migration of two coils, one of which was retrieved, and a transient junctional tachycardia in one patient. In an additional three patients with multiple coronary artery fistulas, transcatheter occlusion was not attempted.

Adolescent

Effect of baffle fenestration on outcome of the modified Fontan operation.

BACKGROUND: The "fenestrated Fontan" (surgical baffle fenestration followed by transcatheter test occlusion and permanent closure after postoperative recovery) was adopted in an effort to reduce perioperative mortality and morbidity. This study assesses the effect of baffle fenestration on outcome. METHODS AND RESULTS: Patients having a modified Fontan operation with a cavocaval baffle and cavopulmonary anastomosis were retrospectively selected for study. Those with baffle fenestration (n = 91) were compared with those without baffle fenestration (n = 56) with respect to preoperative risk factors, age, anatomy, surgical date, and presence or absence of a previous bidirectional cavopulmonary anastomosis. Outcome variables were failure (death or take-down) and duration of postoperative pleural effusions and hospitalization. Survival and clinical status after hospital discharge were ascertained. The two groups did not appear to differ with respect to age or anatomic diagnosis. Patients having baffle fenestration were at significantly greater preoperative risk by univariate and multivariate analysis (p < 0.01). Operative failure was low in both groups (11% without and 7% with baffle fenestration, p = NS). Durations of pleural effusions and hospitalization were significantly shorter with baffle fenestration (p < 0.01). Neither date of surgery nor a previous bidirectional cavopulmonary anastomosis appeared to contribute to improved outcome. Patients with baffle fenestration had lower postoperative systemic venous pressure (p < 0.01). There were no late deaths. Functional status in both groups is good (82% in New York Heart Association class I). CONCLUSIONS: Baffle fenestration is associated with low mortality, significantly less pleural effusion, and significantly shorter hospitalization among high-risk patients having a modified Fontan operation.

Cardiac Surgical Procedures

Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella.

In 14 patients undergoing transcatheter closure of a large (greater than 4 mm diameter) patent ductus arteriosus, occlusion was attempted with use of the Bard Clamshell septal umbrella. Patient age ranged from 0.7 to 30.4 years. Isolated patent ductus arteriosus was present in 11 patients; 3 had additional congenital heart lesions. Moderate or severe pulmonary hypertension was present in four patients. The diameter of the patent ductus arteriosus ranged from 4.5 to 14 mm, as determined by contrast injection through an 11F sheath or by balloon sizing; it appeared larger by this method than by the standard angiographic method. All 14 patent ductus arteriosi were successfully closed. Prior embolization of a Rashkind umbrella was the reason for using a Clamshell device in three patients; one additional embolization of a Clamshell device occurred. All errant devices were retrieved at cardiac catheterization, without associated hemodynamic instability. No other complications occurred. Among the 14 patients, 11 had complete ductal closure by Doppler color flow mapping at last follow-up and 3 had trivial residual flow. All four patients having associated complex lesions or pulmonary hypertension, or both, had symptomatic improvement after the procedure, although one child (with Shone's anomaly) died 3 months later. The Clamshell device provides stable and effective closure of a large patent ductus arteriosus, and allows transcatheter closure to be offered to some patients who were previously considered unsuitable for this procedure.

Adolescent

Preoperative transcatheter closure of congenital muscular ventricular septal defects.

BACKGROUND: Surgical repair of muscular ventricular septal defects, particularly those associated with complex heart lesions carries a higher risk of reoperation and death than the repair of membranous defects. Closing a muscular defect through an incision in the systemic ventricle may cause late ventricular dysfunction. In a collaborative approach to this problem, we undertook preoperative transcatheter closure of muscular ventricular septal defects remote from the atrioventricular and semilunar valves, followed by the surgical repair of associated conditions. METHODS: In 12 patients selected jointly by a cardiologist and a cardiac surgeon, we attempted preoperative transcatheter umbrella closure of 21 defects. Half the patients had associated complex heart lesions; the others had had pulmonary-artery banding to reduce the amount of left-to-right shunting. Half had severe ventricular septal deficiency. RESULTS: All 21 defects were successfully closed without major complications. Subsequent cardiac surgery for associated conditions in 11 of the 12 patients resulted in a mean pulmonary-to-systemic flow ratio of 1.1, indicating minimal residual left-to-right shunting; 1 patient awaited surgical repair. No deaths, reoperations, or late complications have occurred after a follow-up of 7 to 20 months. CONCLUSIONS: A collaborative approach using transcatheter closure followed by the surgical repair of associated cardiac lesions may decrease rates of operative mortality, reoperation, and left ventricular dysfunction in patients with muscular ventricular septal defects.

Adult

Corrected transposition in situs inversus. Biventricular repair of associated cardiac anomalies.

Corrected transposition of the great arteries (C-TGA) in situs inversus [I,D,D] is a rare variant of C-TGA (5-8% of the cases). Few anatomic and surgical data on this anomaly have been published. Between 1974 and 1990, 13 such patients (mean age, 12.7 +/- 8.6 yr) underwent repair of associated cardiac anomalies, including ventricular septal defect (VSD) and pulmonary outflow tract obstruction (POTO) in all 13 patients and atrial septal defect (ASD) in 11. Systemic venous anomalies were present in four. Nine patients also had dextrocardia. Patches to close the VSD were placed on the right side of the ventricular septum (through a right [systemic] ventriculotomy) in two patients and on the left side of the ventricular septum in the other 11 via a left ventriculotomy in one or a morphological right (left-sided) atriotomy in 10. The POTO was relieved directly in five patients and bypassed by a left ventricle-pulmonary artery conduit in the other eight. There was one early death due to cerebral hemorrhage. Two patients required a pacemaker for permanent heart block. Other rhythm disturbances included transient heart block in three patients and late atrial fibrillation in one. All the survivors are asymptomatic as late as 15.5 years after the repair. One patient had conduit revision 10.5 years after the initial operation, two had residual POTO of greater than 40 mm Hg, and none had residual VSD. In conclusion, patients with [I,D,D] C-TGA present with a relatively uniform subset of anatomic lesions, including predominantly ASD, VSD, and POTO.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Vessel Prosthesis

Balloon angioplasty for congenital mitral stenosis.

We attempted balloon angioplasty in 9 children (ages 0.1 to 10 years) with congenital mitral stenosis. All were symptomatic with severe congestive heart failure and failure to thrive. Effective reduction in mitral gradient was initially achieved in 7 patients. For the entire group, mean valve gradient decreased from 14.8 +/- 5.0 to 8.1 +/- 6.7 mm (p = 0.0007) and mean valve area increased from 1.1 +/- 0.5 to 1.8 +/- 0.9 cm2/m2 (p = 0.003). More than mild mitral regurgitation developed in 2 patients but none required surgery for mitral regurgitation. Poor gradient relief followed dilation of valves with unbalanced chordal attachments, with restriction to the valve apparatus as in mitral arcade, and where the obstruction was not purely valvar as it is with a supramitral ring. No strokes, infection or deaths were due to the procedure. Based on these data, balloon angioplasty of congenital mitral stenosis should be considered before mitral valve replacement in younger patients and in those in whom mitral valve replacement would be problematic.

Angioplasty, Balloon

Long follow-up (to 43 years) of ventricular septal defect with audible aortic regurgitation.

From 1946 to March 1989, 92 patients (33 women and 59 men) were seen with ventricular septal defect (VSD) and audible aortic regurgitation (AR). The VSD was subcristal in 62 patients, subpulmonary in 21 and unknown in the remaining 9. The median age of onset of AR was 5.3 years. The risk of developing AR was 2.5 times greater in those with a subpulmonary VSD. The aortic valve was tricuspid in 90% and bicuspid in 10%. Prolapse was seen in 90% of those with subcristal VSD and in all with subpulmonary VSD. Pulmonary stenosis was seen in 46% of the patients with gradients ranging from 10 to 55 mm Hg. The incidence of infective endocarditis was 15 episodes/1,000 patient years. Among 20 patients followed medically, for 297 patient years, 1 died (1959) and most have been stable, including 2 followed for greater than 30 years. In the 72 patients operated on, there were 15 perioperative and 5 late deaths. Operations consisted of VSD closure alone in 7, VSD closure and valvuloplasty in 50 and VSD closure and aortic valve replacement in the other 15. Valvuloplasty was more effective in those operated on under age 10 compared to those older than 15 years (46 vs 14%). The durability of the valvuloplasty was 76% at 12 years and 51% at 18 years.

Actuarial Analysis

Early results and follow-up of balloon angioplasty for branch pulmonary artery stenoses.

Two hundred eighteen balloon angioplasty procedures were performed in 135 patients with branch pulmonary artery stenoses from June 1984 to February 1989. Arteries were dilated in patients with tetralogy of Fallot (n = 49), tetralogy of Fallot/pulmonary atresia (n = 64), isolated peripheral pulmonary artery stenoses (n = 58) and "other" lesions (the majority had truncus arteriosus or single ventricle and surgically induced pulmonary artery stenoses (n = 47). Mean age at dilation was 6.6 +/- 6.3 years (range 1 month to 38.5 years). The mean diameter of the lesion increased from 3.8 +/- 1.7 to 5.5 +/- 2.1 mm with dilation (p = 0.001). The overall success rate was 58% (127 of 218 dilations), assessed by the following criteria: an increase greater than or equal to 50% of predilation diameter, an increase greater than 20% in flow to the affected lung or a decrease greater than 20% in systolic right ventricular to aortic pressure ratio. Success did not correlate with patient age. Mean balloon to artery ratio was higher in successful (4.2) than in failed (3.0) angioplasty procedures (p = 0.0001). There were four early deaths: two of the patients had pulmonary artery rupture with angioplasty performed less than 1 month after pulmonary artery surgery. An aneurysm occurred in 11 arteries and transient pulmonary edema in four patients. At angiography performed a mean of 10 months (range 1 to 54) after dilation, the mean diameter of 57 arteries was unchanged (5.5 versus 5.4 mm). However, 5 of 32 initially successfully dilated vessels had returned to predilation size as a result of restenosis.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Double-umbrella closure of atrial defects. Initial clinical applications.

Forty patients were catheterized for closure of atrial septal defects with the Rashkind patent ductus arteriosus umbrella device, a modified Rashkind umbrella device, and the newly designed Lock Clamshell Occluder. Patients weighed 8 kg or more (a requirement for transvenous access with the 11F delivery sheath) and had defects suitable for closure based on two-dimensional echocardiography. The new device was at least 1.6 times the diameter of the atrial septal defect as determined by balloon sizing at catheterization. Patients were followed up by telephone, clinical examination, and echocardiography at 6 months. We attempted closure in 34 patients, with atrial septal defects ranging in diameter from 3 to 22 mm; device sizes ranged from 17 to 33 mm. Initial device position immediately after release was correct in all patients. A cerebral embolus occurred in one elderly patient before device placement--the patient died 1 week later. Two instances of early device embolization occurred, and devices were retrieved by catheter without complication. Follow-up of 31 patients discharged with devices in place, for a total of 31 patient-years, has yielded no umbrella-related complications. Adequate imaging studies in 19 patients 6.5 months after device placement revealed no atrial shunt in 12; residual flow through separate, previously unrecognized atrial septal defects occurred in two; and small residual leaks (less than 3 mm) around devices were present in five patients. This initial success indicates that double-umbrella closure of atrial septal defects will aid in the treatment of intracardiac defects.

Angiography

Bidirectional cavopulmonary anastomosis as interim palliation for high-risk Fontan candidates. Early results.

Thirty-eight patients considered to be at increased risk for a Fontan repair underwent bidirectional cavopulmonary anastomosis. Twenty-one of the 38 had concurrent pulmonary artery reconstruction. Fontan risk factors included pulmonary artery distortion, elevated pulmonary artery resistance (greater than 2 Woods units) and/or pulmonary artery pressure (mean, greater than 18 mm Hg), atrioventricular valve regurgitation, systemic ventricular dysfunction, complex venous anatomy, and subaortic obstruction. There were no deaths, either early or late. Median arterial oxygen saturation increased from 79% to 84% (p less than 0.01). Median hospital stay was 8 days. No patient had pleural effusions after 7 days. Three patients had significant surgical complications. Five patients had inadequate relief of cyanosis; three of these had venous collaterals and two had severe ventricular dysfunction; the latter two patients subsequently had strokes. One of the patients with persistent cyanosis required a systemic-to-pulmonary artery shunt. We conclude that a bidirectional cavopulmonary shunt, with pulmonary artery reconstruction when indicated, provides adequate relief of cyanosis in most patients with single-ventricle lesions who are considered to be at increased risk for a Fontan repair. Relief of ventricular volume overload and pulmonary artery distortion may improve Fontan candidacy. Also, patients with persistent cyanosis after bidirectional cavopulmonary anastomosis should be catheterized for location and occlusion of venous collaterals. Further follow-up is necessary to determine the place of bidirectional cavopulmonary anastomosis in the management of patients at increased risk for a Fontan repair.

Anastomosis, Surgical

Balloon dilation of branch pulmonary artery stenosis.

We consider balloon angioplasty to be an established, highly useful procedure in the management of branch pulmonary artery stenosis. It is successful in approximately 60% of cases. Current figures would indicate a low but significant mortality rate (1%) and a risk of aneurym formation (3%). Patients undergoing balloon angioplasty in the acute postpulmonary artery surgical period constitute a particularly high risk group for vessel rupture. Restenosis after branch pulmonary dilation is infrequent, but does occur. Further improvements in the use of this procedure should probably involve the use of expandable intravascular stents for patients with failed dilations or evidence of restenosis.

Aneurysm

Intrauterine supraventricular tachycardia.

Six examples of intrauterine supraventricular tachycardia together with 31 previously reported cases are described and analyzed. Among the 37 infants, structural heart disease was present in only four (11%), three of whom died. Males comprised 68% of the group without identifiable heart disease or pre-excitation. Congestive heart failure was evident in 62% of the infants at birth or shortly thereafter; ascites was the predominant finding in three (8%). Neither the duration of SVT nor heart rate was predictive of the clinical status at birth. Infants without underlying heart disease or conduction abnormalities had a benign course after the neonatal period. Thirty-eight percent of the babies converted to sinus rhythm during or shortly after delivery without medication, and most of the others converted after digitalization. The failure of maternal digitalization to convert SVT to sinus rhythm in two of our infants was perhaps related to subtherapeutic maternal and fetal digoxin levels. Newborn infants presenting with unexplained ascites or congestive heart failure should have an ECG to determine whether pre-excitation is present, and their cardiac rhythm should be monitored for several days.

Ascites

His bundle electrogram after intracardiac repair of tetralogy of Fallot. Analysis of data in 59 patients.

His bundle electrograms were recorded in 59 patients after intracardiac repair of tetralogy of Fallot and were correlated with the postoperative electrocardiogram. Except for five patients with first degree atrioventricular block postoperatively all patients in Group A (those with either a normal electrocardiogram or solitary right bundle branch block) had a normal A-H interval (77.7 +/- 21.6 msec) (mean +/- standard deviation); all had a normal H-V interval (39.5 +/- 7.2 msec). Patients in Group B (bifascicular block) tended to have a normal A-H interval (97.2 +/- 26.2 msec) with a prolonged H-V interval (48.8 +/- 10.7 msec). Patients in Group C (trifascicular block) had prolongation of both the A-H (160.0 +/- 32.4 msec) and the H-V interval (58.8 +/- 10.6 msec) by comparison with control values. Patients in Group D (transient complete heart block) had a normal A-H interval (79.5 +/- 28.2 msec) but a prolonged H-V interval (57.8 +/- 16.4 msec), similar to that in Group C. A good hemodynamic result was associated with a normal H-V interval; a prolonged interval accompanied a poor result.

Adolescent

Cardiac output measured by thermodilution in infants and children.

To determine the accuracy and reproducibility of cardiac output determination by thermodilution (COT) in children, simultaneous outputs were measured by the Fick technique (COF) (using measured oxygen consumption) and thermodilution in 26 children, ranging in age from 8 to 86 months, who were undergoing cardiac catheterization. There was excellent correlation between mean output by thermodilution and by the Fick technique: COT = 1.10 COF -- 0.2 l/minute, R = 0.91. In three-quarters of the patients with COT differed by 15% or less and in none differed by more than 25%. Serial values of thermodilution outputs were reproducible in each patient with a SD of 5.5%. Our observations indicate that COT is accurate, reproducible, and valuable in the care of critically ill infants and children.

Cardiac Catheterization