PubMed Health⌕ Search

Biomedical subjects

J F Piechaud

Publications and source records attributed to J F Piechaud.

At least 19 recordsLinked to original sources

[Multicentre study of percutaneous closure of interventricular muscular defects with the aid of an Amplatzer duct occluder prosthesis].

Percutaneous closure of interventricular defects is an alternative or adjunct to surgery with the disadvantage of a sometimes prolonged and difficult catheterisation only during which the choice of prosthesis can be determined. Despite the existence of an occlusion prosthesis, the Amplatzer Septal Defect Occluder, specifically conceived for this purpose, an arterial canal occlusion prosthesis such as the Amplatzer Duct Occluder is sometimes better suited for the occlusion of certain interventricular defects. Since 1999, 11 Amplatzer Duct Occluders were used for the closure of interventricular muscular defects, during 10 catheterisations in 9 patients with a median age of 2.5 (0.1 to 43.9) years. In 5 cases there were residual septal defects after failure of initial surgery. 10 were successful with prostheses of 6/4 mm to 12/10 mm while in one patient the interventricular communication had to be closed surgically because the 14/12 mm prosthesis could not be positioned due to a tortuous introduction route. The only complication was a pericardial effusion requiring surgical drainage in one infant. After a median follow up of 2.1 (0.3 to 4.2) years, all of the patients had a satisfactory functional status, with minimal residual shunt on echocardiography in 2 cases. The Amplatzer Duct Occluder therefore seems better adapted for the closure of post-operative residual interventricular communications, with a thickened interventricular septum or even when the tricuspid valve is very close to the right ventricular side of the orifice.

Adolescent↗

Coronary angiography using 4 or 6 French diagnostic catheters: a prospective, randomized study.

Diagnostic catheter size has been progressively decreased in order to reduce complications (particularly access-site complications) and permit early ambulation after coronary angiography. However, excessive down-sizing can result in poor catheter conformation and poor imaging quality of coronary angiograms (CA). This study randomly compared the accuracy and angiographic quality (QUAL) of CA performed with 4 French (Fr) vs. 6 Fr diagnostic catheters. Injections were done manually using a low-viscosity, non-heated, low-osmolality contrast media (Iomeprol). CAs were performed via the femoral approach using Judkins catheters. Handling, torque, selectively and stability were graded from 1 (excellent) to 4 (unacceptable) by the operator. QUAL was also graded from 1 (unacceptable) to 10 (excellent) by the operator in all patients and by an independent Core laboratory in 50 patients matched for gender and weight. Between January and April 1997, a total of 405 consecutive patients were randomized. Mean age was 63.4 +/- 11.1 years and 79% were male. Clinical characteristics of patients, quality of left coronary catheter and cross-over rates (1.5% with 6 Fr vs. 3.9% with 4 Fr catheters) were similar in both groups. Using the right coronary catheters, the only difference was handling, which was found to be easier with 6 Fr catheters (1.16 +/- 0.55 vs. 1.34 +/- 0.77, respectively; p = 0.007). Similarly, handling difficulty using the pigtail catheter was the only significant difference between the two groups (1.16 +/- 0.50 vs. 1.33 +/- 0.77, respectively; p = 0.009), but no cross-over was necessary in either group. The QUAL of CA was slightly but significantly better with 6 Fr than with 4 Fr catheters but considered non-diagnostic (< 7/10) in 1.4% vs. 6.8% of left CAs (p = NS). Procedural time (21.0 +/- 7.2 minutes vs. 19.0 +/- 8.1 minutes; p = 0.007) was shorter with 4 Fr catheters, but x-ray exposure, compression times and amount of contrast media used were similar. Ambulation was obtained at 2 hours in 15.1% vs. 34.0% of patients (p < 0.001) and at 4 hours in 43.8% vs. 52.4% (p < 0.05), respectively. The incidence of the worst access-site complication (moderate hematoma) was similar (1%) in both groups. CA can be performed using 4 Fr catheters and manual injections of low-viscosity contrast media with acceptable angiographic results in the majority of cases. This is associated with a shorter procedural time and earlier ambulation, and a decreased but acceptable angiographic quality.

Age Factors↗

A European multicentric experience using the CardioSEal and Starflex double umbrella devices to close interatrial communications holes within the oval fossa.

In this review, we describe the experience from 13 European centres using the CardioSEAL and Starflex double umbrella devices to close interatrial communications within the oval fossa (so-called 'secundum' defects). Between October 1996 and April 1999, the procedure was attempted in 334 patients with a mean age of 12 years and a mean weight of 44kg. The mean measured stretched diameter of the defect was 15 mm. In the overall group, the defect was solitary in 245 patients (73%), multiple in 21 (6%), associated with an aneurysm of the flap valve in 15 (5 %), was represented by patency of the oval foramen in 44 (13%), and was a fenestration in a Fontan repair in 9 (3%). In all patients, the devices were inserted under general anesthesia, using fluoroscopic and transesophageal echocardiographic control. Implantation was achieved in 325 (97,3%). The device embolized within either a few minutes or a few hours in 13 patients (4%). Of these, uncomplicated surgical repair was undertaken in 10, while the device was retrieved in 3 using catheters and a second device was successfully implanted. Residual shunting was detected immediately after the procedure in 41% of the patients, with the incidence decreasing to 31% at discharge, 24% at 1 month, 21% at 6 months, and 20.5% at one year. During the period of follow-up, elective surgical repair became necessary in two patients, due to malposition of the device in one, and late embolization in the other. Fractures of arms were seen in 6.1 %, most commonly with the largest devices. All those with fractured arms of the device were asymptomatic, and no clinical complications related to the fractures were observed. There were no arrhythmias, endocarditis, valvar distortion, thromboembolic events, or other complications. After one year of follow-up, clinical success, defined as complete closure of the defect or presence of only a trivial leak, had been obtained in 92.5% of the patients. We conclude, therefore, that these devices produce excellent results when used to close defects of small to moderate size. Results are less than optimal, or else complications ensure, when attempts are made to close very large defects.

Adolescent↗

[Immediate revascularization by angioplasty and coronary stents in patients over age 80 with myocardial infarction].

The aim of this study was to assess the results of revascularisation by angioplasty and stenting in octogenarians in the acute phase of myocardial infarction. One hundred and four patients over 80 years of age were identified between January 1995 and April 1995 out of 906 patients admitted within 24 hours of the onset of myocardial infarction. The average age was 85 +/- 4 years with a female predominance (63.4%) and a high incidence of cardiogenic shock (28.8%). Ninety eight patients underwent angioplasty with coronary stenting in 81 patients (82.6%) within 39 +/- 35 min of hospital admission. A primary success was obtained in 96% of cases with restitution of TIMI 3 flow in 83.6% of cases. Hospital mortality was 26.5%, highly influenced by the presence of cardiogenic shock (60.7% versus 12.8% without shock). Univariate analysis showed cardiogenic shock (p < 0.0001) and ejection fraction (p = 0.009) to be predictive of mortality, and a tendency in favour of TIMI 3 flow (p = 0.07) and stent implantation (p = 0.09). Complications were rare: 1% of minor cerebrovascular accidents and 4% of vascular complications. There were no cases of emergency bypass surgery and only one patient had a recurrence of ischaemia at 30 days. The authors conclude that the results at 1 month in a high risk group of octogenarians seem to be in favour of an invasive management with coronary stenting in the acute phase of myocardial infarction.

Aged↗

Feasibility of routine transradial coronary angiography: a single operator's experience.

The aims of this study were to assess the feasibility of routine transradial coronary angiography in a standard population of patients with presumed coronary artery disease over a period of time long enough to allow for technical evolution and evaluation of a single operator's learning curve, and to provide data for a randomized comparison versus the femoral approach. Between June 1994 and March 1997, transradial angiography was attempted in 1,000 patients. Approximately 25% of these patients were excluded because of an abnormal Allen test. Except in the case of acute myocardial infarction, there was no selection based on symptoms, age, sex, weight or size in the absence of double internal mammary artery bypass graft operation or simultaneous right heart catheterization. Symptoms and angiographic results were typical of a standard population. The right radial approach was used in 95% of the cases for ease of handling and comfort of a right-handed operator. Radial artery puncture and catheterization success was obtained in 97.6% of the cases; the left coronary artery was selectively catheterized in 100%, right coronary artery in 98%, left ventricle in 96.9%, mammary artery grafts in 100% and saphenous grafts in 97.2%. Average procedure duration was 18 +/- 9 minutes, and decreased progressively with experience and catheter strategies. The optimal catheter selection would seem to be a single catheter, either left Amplatz or Champ, for both coronary arteries. Two coronary complications and 3 transient neurological complications occurred, but no clinically significant vascular complications requiring surgery or transfusion were reported. Transradial angiography seems to be a routine approach that should now be compared with the femoral approach and supersede the brachial approach whenever possible.

Aged↗

An approach for dose finding of drugs in infants: sedation by midazolam studied using the continual reassessment method.

AIMS: No drug has been demonstrated to provide simultaneously appropriate sedation, safety and lack of disturbance of the measured parameters during cardiac catheterization in infants. The objective of this study was to estimate the dose of midazolam, administered rectally, that would provide a 90% probability of adequate sedation in infants during cardiac catheterization. A sedation score > or =4 (six-point scale) 30 to 60 min after dosing was rated as a success. METHODS: A double-blind, continual reassessment method using a Bayesian approach has been used. Sixteen infants were administered a single midazolam dose, within a 0.1 to 0.6 mg kg(-1) dose range. RESULTS: Consecutive failures led to allocation of the highest dose to 15 out of 16 patients. The final estimated probability of failure of the 0.6 mg kg(-1) dose was 81% (95% CI: 78.5 to 84%). The time to reach a score > or =4 was longer than expected and the median duration-time at score > or =4 was shorter (15 min) than expected. CONCLUSIONS: Delayed absorption and low rectal bioavailability may explain these data. Higher doses or different routes of administration may lead to the expected sedation, but the safety of doses higher than 0.6 mg kg(-1) administered rectally has not been evaluated. The therapeutic strategy for sedation of this category of infants in the hospital has now been changed based on the present results in that rectal midazolam has been abandoned in this indication.

Administration, Rectal↗

Endomyocardial biopsies for early detection of mitochondrial disorders in hypertrophic cardiomyopathies.

Considering the high proportion of unexplained hypertrophic cardiomyopathies on the one hand and the occurrence of cardiomyopathies in several mitochondrial disorders on the other, we hypothesized that isolated hypertrophic cardiomyopathies in infancy could occasionally be the result of defects of oxidative phosphorylation. By means of a scaled-down technique, we were able to investigate oxidative phosphorylation on minute amounts of endomyocardial tissue (1 mg) in three patients with concentric hypertrophic cardiomyopathy (shortening fraction in diameter, 18% to 27%; normal mean +/- 1 SD, 33 +/- 3%) and in control subjects. Although the absolute respiratory chain enzyme activities in the endomyocardial biopsy specimens of the patients were within the low normal range, the determination of the activity ratios allowed us to ascribe hypertrophic cardiomyopathies to respiratory chain enzyme abnormalities in all three cases (complex I, two cases; multiple enzyme deficiency, one case). The respiratory chain enzyme activity ratios, which are normally constant irrespective of the tissue tested, were markedly abnormal in all three patients (cytochrome c oxidase/reduced nicotinamide-adenine dinucleotide cytochrome c reductase, 4.6 to 10.4; normal mean +/- 1 SD, 2.9 +/- 0.5). We conclude that mitochondrial disorders should be regarded as potential causes of hypertrophic cardiomyopathy in early infancy. Because cardiac catheterization is routinely performed for hemodynamic investigation of cardiomyopathies, we suggest that endomyocardial biopsies be considered as a tool for early detection of mitochondrial cardiomyopathies, especially in hypertrophic forms of the disease.

Biopsy↗

Percutaneous balloon valvuloplasty in neonates with critical aortic stenosis.

Percutaneous balloon valvuloplasty was attempted in 10 newborn infants with critical aortic valve stenosis and severe congestive heart failure. Three had a very small left ventricle and aortic anulus. In one infant, the aortic valve could not be passed, and in another infant, a technical error resulted in severe valvular damage, aortic insufficiency and death. Among the eight patients who had effective dilation, the stenosis was relieved in seven as assessed by a significant decrease in transvalvular pressure gradient, improvement of left ventricular contraction and eventual inversion of the ductal shunting. The procedure failed in the only patient whose dilation was performed with an undersized balloon. Aortic insufficiency occurred in three infants and was severe (perforated cusp) in one, moderate in one whose valve was dilated with an excessively large balloon and mild and transient in one. None of the three infants with a very small left ventricle recovered (two died and one underwent cardiac transplantation). Among the seven infants with a left ventricle of acceptable size, three underwent subsequent aortic valvotomy; one of these died and two bad good results. The remaining four are doing well 16 +/- 5 months later (mean +/- SD) with mild to moderate residual aortic stenosis and normal left ventricular function. In conclusion, percutaneous balloon valvuloplasty is an acceptable alternative to surgery in neonates with critical aortic valve stenosis. Incidence of complications and good relief of the obstruction depend on a careful technique. Immediate results are similar to those of surgery. Late prognosis depends on the quality of the left heart structures.

Aortic Valve Insufficiency↗

Anomalous left coronary artery arising from the pulmonary artery in infancy: is early operation better?

From January 1975 to January 1987, 21 consecutive infants aged less than six months (mean (SD) 2.6 (1.2] were admitted with anomalous origin of the left coronary artery from the pulmonary artery. In the first 12 patients, who were seen up to 1982, operation was performed after the age of one year (mean (SD) 29 (29) months) (group 1). The next nine infants, seen from 1983 to 1987, had their operations within a few weeks of the onset of symptoms (mean (SD) age 4.8 (1.4) months) (group 2). In group 2 the left coronary artery was relocated into the aorta, whereas in group 1 there was additional resection of the left ventricular wall or mitral valvoplasty or both. At presentation there were no differences in age, clinical condition, heart enlargement, and echocardiographic left ventricular dysfunction between groups 1 and 2. Seven of the 12 patients in group 1 died, five while they were awaiting operation (three died suddenly at home) and two at operation. The five survivors are doing well 6.4 (3.1) years after operation with normal left ventricular function which improved slowly over several months after operation. Two of the nine patients in group 2 died; both deaths occurred at or soon after operation. The seven survivors are doing well 1.8 (0.9) years after operation. In three, left ventricular function recovered within three weeks; and there was even partial or total regression of the Q waves in the supposedly necrotic areas. In the remaining four the pattern of improvement in left ventricular function resembled that in group 1. Operation should be undertaken early in infants with anomalous left coronary artery arising from the pulmonary artery because the procedure is relatively safe, prevents a high natural mortality, and offers a better chance of a faster recovery of left ventricular function.

Age Factors↗