Isolated kidney controlled perfusion with true physiological pulsatile waveform.

A computer controlled perfusion system has been developed to study the behavior of perfused kidneys in several conditions. The system is designed to perform kidney perfusions at constant pressure and low temperature (about 4 degrees C). We compared 2 types of perfusion pumps, a classical roller pump widely used in hemodialysis circuits and a vacuum powered tubular pump with active valves developed by our group and able to produce a flow pattern very similar to the pulse wave in the human circulatory system. In this preliminary study, we show the hydrodynamics obtained with both pumps in isolated hypothermic kidneys perfused with this system. The different flow patterns with both pumps seem to determine differences in the preservation conditions of the kidney.

Animals↗

Tubular vacuum-powered blood-pumping device with active valves.

We propose a new vacuum-driven blood pump having a tubular shape with active valves. This design avoids any possible problems caused by membrane breakage, thereby minimizing the risk of gas embolic events and stagnation regions. By using active valves, it is possible to ensure better flow control and minimize pressure gradients inside and outside the pump. The low cost of the pump's disposable parts enables it to be used for such applications as a ventricular assist device, a pulsatile pump device in extracorporeal circulation, a pump in hemodialysis and apheresis circuits, and a pump in extracorporeal membrane oxygenator systems.

Equipment Design↗

Development and clinical assay of the BCM ventricular assist device.

The development of a ventricular assist device is depicted. The seven subprograms that make up the project are described briefly. Results obtained during the clinical assay showed that the new design of the input cannula working as a false auricle provides better efficiency, as well as a certain level of autoregulation for the device.

Aged↗

Improvement of the hydrodynamic response of a ventricular assist device: a false auricle solution.

We propose a new design of the auricular cannula in ventricular assist devices (VADs), consisting of a collapsible large cannula with a capacity approximately equal to the ejection volume of the VAD. The device works as a false auricle and filters the negative pressure that occurs during diastole. We show that the use of this type of cannula improves the hydrodynamic efficiency and the stability of the working conditions. Moreover, during chronic implantation in sheep, hemolysis stays well below pathological levels. These improvements result in much better controllability of the whole VAD.

Animals↗

Blood biochemistry values of sheep (Ovis aries ligeriensis).

1. Analysis of biochemical parameters were carried out on material pooled from 30 female sheep (Ovis aries ligeriensis). 2. The values determined were for the common metabolites and enzymes utilized for specific studies in general metabolism (urea, glucose, cholesterol, lipids, bilirubin, uric acid, creatinine, alkaline phosphatase, GOT, GPT, LDH, LAP, CGT, CK and amylase). 3. Results of these studies were compared with values from normal human adults. 4. The differences obtained in human and sheep ranges can be explained by the different physiology of the two species. 5. This study gives values for the sheep as an experimental animal in biomedical research.