PubMed Health⌕ Search

Biomedical subjects

J Feijen

Publications and source records attributed to J Feijen.

At least 19 recordsLinked to original sources

First steps towards tissue engineering of small-diameter blood vessels: preparation of flat scaffolds of collagen and elastin by means of freeze drying.

Porous scaffolds composed of collagen or collagen and elastin were prepared by freeze drying at temperatures between -18 and -196 degrees C. All scaffolds had a porosity of 90-98% and a homogeneous distribution of pores. Freeze drying at -18 degrees C afforded collagen and collagen/elastin matrices with average pore sizes of 340 and 130 mum, respectively. After 20 successive cycles up to 10% of strain, collagen/elastin dense films had a total degree of strain recovery of 70% +/- 5%, which was higher than that of collagen films (42% +/- 6%). Crosslinking of collagen/elastin matrices either in water or ethanol/water (40% v/v) was carried out using a carbodiimide (N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride, EDC) in combination with a succinimide (N-hydroxysuccinimide, NHS) in the presence or absence of a diamine (J230) or by reaction with butanediol diglycidylether (BDGE), followed by EDC/NHS. Crosslinking with EDC/NHS or EDC/NHS/J230 resulted in matrices with increased stiffness as compared to noncrosslinked matrices, whereas sequential crosslinking with the diglycidylether and EDC/NHS yielded very brittle scaffolds. Ethanol/water was the preferred solvent in the crosslinking process because of its ability to preserve the open porous structure during crosslinking. Smooth muscle cells were seeded on the (crosslinked) scaffolds and could be expanded during 14 days of culturing.

Biomechanical Phenomena↗

Electrospinning of collagen and elastin for tissue engineering applications.

Meshes of collagen and/or elastin were successfully prepared by means of electrospinning from aqueous solutions. Flow rate, applied electric field, collecting distance and composition of the starting solutions determined the morphology of the obtained fibres. Addition of PEO (M(w)=8 x 10(6)) and NaCl was always necessary to spin continuous and homogeneous fibres. Spinning a mixture of collagen and elastin resulted in fibres in which the single components could not be distinguished by SEM. Increasing the elastin content determined an increase in fibres diameters from 220 to 600 nm. The voltage necessary for a continuous production of fibres was dependent on the composition of the starting solution, but always between 10 and 25 kV. Under these conditions, non-woven meshes could be formed and a partial orientation of the fibres constituting the mesh was obtained by using a rotating tubular mandrel as collector. Collagen/elastin (1:1) meshes were stabilized by crosslinking with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS). This treatment afforded materials with a high thermal stability (T(d)=79 degrees C) without altering their original morphology. Upon crosslinking PEO and NaCl were fully leached out. Smooth muscle cells grew as a confluent layer on top of the crosslinked meshes after 14 d of culture.

Animals↗

Implicit and explicit memory for spatial information in Alzheimer's disease.

There is abundant evidence that memory impairment in dementia in patients with Alzheimer's disease (AD) is related to explicit, conscious forms of memory, whereas implicit, unconscious forms of memory function remain relatively intact or are less severely affected. Only a few studies have been performed on spatial memory function in AD, showing that AD patients' explicit spatial memory is impaired, possibly related to hippocampal dysfunction. However, studies on implicit spatial memory in AD are lacking. The current study set out to investigate implicit and explicit spatial memory in AD patients (n=18) using an ecologically valid computer task, in which participants had to remember the locations of various objects in common rooms. The contribution of implicit and explicit memory functions was estimated by means of the process dissociation procedure. The results show that explicit spatial memory is impaired in AD patients compared with a control group (n=21). However, no group difference was found on implicit spatial function. This indicates that spared implicit memory in AD extends to the spatial domain, while the explicit spatial memory function deteriorates. Clinically, this finding might be relevant, in that an intact implicit memory function might be helpful in overcoming problems in explicit processing.

Aged↗

A novel time resolved fluorometric assay of anoikis using Europium-labelled Annexin V in cultured adherent cells.

BACKGROUND: Adherent cells undergo apoptosis when detached from their home ground, a process called anoikis (homelessness). METHODS: We developed a new and sensitive method to analyse apoptosis and anoikis of adherent cell types using a time resolved fluorometric assay with Europium-labelled Annexin V. Anoikis was induced with tumor necrosis factor-alpha/cycloheximide and three cell fractions of the cell cultures were prepared and analysed. Fraction 1 consisted of adherent cells, analysed while growing on their support (without detachment by trypsinisation). Fraction 2 contained detached cells due to anoikis (floating cells) and fraction 3 contained apoptotic bodies. Both fractions 2 and 3 were present in the culture medium and were isolated by differential centrifugation. RESULTS: TNF-alpha treatment of three different types of adherent cell cultures induced a significant increase of the amount of floating cells (anoikis) and apoptotic bodies compared to control cell cultures. Also in the adherent cell fractions a small amount of apoptosis was observed. CONCLUSIONS: The novel time resolved assay provides the ability to analyse the cell death cascade in adherent cell cultures of the same sample at the same time in a sensitive and reproducible way.

Annexin A5↗

In vivo and in vitro degradation of poly(ether ester) block copolymers based on poly(ethylene glycol) and poly(butylene terephthalate).

Two in vivo degradation studies were performed on segmented poly(ether ester)s based on polyethylene glycol (PEG) and poly(butylene terephthalate) (PBT) (PEOT/PBT). In a first series of experiments, the in vivo degradation of melt-pressed discs of different copolymer compositions were followed up for 24 weeks after subcutaneous implantation in rats. The second series of experiments aimed to simulate long-term in vivo degradation. For this, PEOT/PBT samples were pre-degraded in phosphate buffer saline (PBS) at 100 degrees C and subsequently implanted. In both series, explanted materials were characterized by intrinsic viscosity measurements, mass loss, proton nuclear magnetic resonance spectroscopy (1H-NMR) and differential scanning calorimetry (DSC). In both studies the copolymer with the higher PEO content degraded the fastest, although all materials degraded relatively slowly. To determine the nature of the degradation products formed during hydrolysis of the copolymers, 1000 PEOT71PBT29 (a copolymer based on PEG with a molecular weight of 1000 g/mol and 71 wt% of PEO-containing soft segments) was degraded in vitro at 100 degrees C in phosphate buffer saline (PBS) during 14 days. The degradation products present in PBS were analyzed by 1H-NMR and high performance liquid chromatography/mass spectroscopy (HPLC/MS). These degradation products consisted of a fraction with high contents of PEO that was soluble in PBS and a PEOT/PBT fraction that was insoluble at room temperature. From the different in vitro and in vivo degradation experiments performed, it can be concluded that PEOT/PBT degradation is a slow process and generates insoluble polymeric residues with high PBT contents.

Animals↗

Non-conventional injection molding of poly(lactide) and poly(epsilon-caprolactone) intended for orthopedic applications.

Biodegradable polymers such as poly(lactide) (PLA) and poly(epsilon-caprolactone) (PCL) are increasingly used in biomedical applications as temporary implants. However, melt processing of these materials in particular of PLA is difficult due to the temperature sensitivity. Within this study, PLA and PCL were injection molded conventionally and by using the process shear controled orientation in injection molding (SCORIM) in order to investigate the effect of processing parameters on the physical properties of the moldings. Therefore, flexural testing, differential scanning calorimetry (DSC), wide-angle X-ray diffraction (WAXD), molecular weight (MW) and orientation measurements were performed. PLA showed high sensitivity to melt temperature. In the case of amorphous poly(DL-lactide), the molecular weight and subsequently the ductility is substantially reduced by processing at higher melt temperatures. In the case of crystallizable poly(L-lactide), higher melt temperatures and shear induced by the SCORIM process resulted in enhanced crystallinity, which compromised the mechanical properties. Generally, SCORIM processing improved the mechanical properties, in particular the ductility, by orientating the molecular structure. PCL was shown to be less sensitive to shear and temperature than PLA. Stress at yield and stiffness are more improved by SCORIM processing. However, the processing temperature in combination with the grade used proved to be influential for the mechanical properties of resulting moldings.

Absorbable Implants↗

In vivo behavior of poly(1,3-trimethylene carbonate) and copolymers of 1,3-trimethylene carbonate with D,L-lactide or epsilon-caprolactone: Degradation and tissue response.

The degradation and the tissue response evoked by poly(1,3-trimethylene carbonate) [poly(TMC)] and copolymers of TMC with either 52 mol % D,L-lactide (DLLA) or 89 mol % epsilon-caprolactone (CL) were evaluated in vivo by subcutaneous implantation of polymer films in rats for periods up to one year. Poly(TMC) specimens were extensively degraded after 3 weeks and, as confirmed by histology, totally resorbed in less than a year. A fast linear decrease in thickness and mass without a change in molecular weight was observed. Initially an acute sterile inflammatory tissue reaction, caused by the implantation procedure, was observed, followed by a mild macrophage-mediated foreign body reaction that lasted during the resorption period of the polymer. It is concluded that in vivo, poly(TMC) is degraded via surface erosion involving cellular-mediated processes. The degradation of the copolymers was slower than that of poly(TMC), taking place via autocatalyzed bulk hydrolysis, preferentially of ester bonds. The TMC-DLLA copolymer degraded 20 times faster than the TMC-CL one. In both cases, the tissue reaction upon implantation resembled a sterile inflammatory reaction followed by a foreign body reaction that led to the polymer encapsulation. Significant mass loss was only observed for the TMC-DLLA copolymer, which underwent 96% mass loss in 1 year. When extensive mass loss started, a mild-to-moderate secondary foreign body reaction, related to clearance of the polymer fragments, was triggered. The results presented in this study demonstrate that poly(TMC) and both TMC copolymers are biodegradable and biocompatible materials, making these polymers attractive for the preparation of short- and long-term degradable devices for soft tissue engineering.

Animals↗

Gas plasma etching of PEO/PBT segmented block copolymer films.

A series of poly(ethylene oxide)/poly(butylene terephthalate) (PEO/PBT) segmented block copolymer films was treated with a radio-frequency carbon dioxide (CO(2)) or with argon (Ar) plasma. The effects of (preferential) etching on surface structure, topography, chemistry, and wettability were studied by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and contact angle measurements. In all cases, a granular-type nanostructure was formed after prolonged CO(2) plasma etching. Ar plasma etching generally did not lead to significant changes in surface structure. Regarding surface chemistry, CO(2) plasma treatment caused surface oxidation and oxidative degradation of the films while Ar plasma etching resulted mainly in the preferential removal of PEO blocks. The wettability of all films significantly increased after plasma treatment because of the creation of polar functional groups at the surface. Preliminary goat bone-marrow cell compatibility experiments have shown that all plasma-treated PEO/PBT films induced a greatly enhanced cell adhesion and/or growth compared to untreated biomaterials. This improvement was attributed to changes in surface chemistry during plasma etching rather than to changes in surface structure. These results show that plasma-treated PEO/PBT copolymers have a high potential as scaffolds for bone tissue regeneration.

Animals↗

Poly(ether ester amide)s for tissue engineering.

Poly(ether ester amide) (PEEA) copolymers based on poly(ethylene glycol) (PEG), 1,4-butanediol and dimethyl-7,12-diaza-6,13-dione-1,18-octadecanedioate were evaluated as scaffold materials for tissue engineering. A PEEA copolymer based on PEG with a molecular weight of 300 g/mol and 25wt% of soft segments (300 PEEA 25/75) and the parent PEA polymer (0/100) sustain the adhesion and growth of endothelial cells. The in vivo degradation of melt-pressed PEEA and PEA discs subcutaneously implanted in the back of male Wistar rats was followed up to 14 weeks. Depending on the copolymer composition, a decrease in intrinsic viscosity of about 20-30% and mass loss up to 12% were measured. During the degradation process, erosion of the surface was observed by scanning electron microscopy and light microscopy. The thermal properties of the polymers during degradation were measured by differential scanning calorimetry. During the first 2 weeks, a broadening of the melting endotherm was observed, as well as an increase in the heat of fusion. Porous matrices of PEEAs and PEA could be prepared by molding mixtures of polymer and salt particles followed by leaching of the salt.

Amides↗