[Study of the correlation of sonographic and scintigraphic results in measuring stomach emptying].

"Stomach cockade" can be readily imaged sonographically, so that it has also been possible to carry out studies of gastric motility or measurements of gastric emptying times of fluids. However, the results of measurements should be verified by reference methods using new investigation techniques. For this reason, we measured synchronously by sonography and scintigraphy the emptying of test fluids from the stomach in patients with diabetes mellitus and suspected gastroparesis. We found a correlation of the two methods of measurement, so that sonographic measurement can be regarded as confirmed by scintigraphy as a reference method.

Adult

Hybrid reconstruction algorithm for x-ray computed tomography.

A hybrid reconstruction algorithm (HRA) is derived for fan beam geometry for use with systems utilizing a linear array of detectors. The algorithm uses fan beam geometry with a modified parallel beam reconstruction formula. The parallel beam algorithm is used with fan beam geometry by a simple geometric conversion and a different back projection formula. Correction for center of rotation shift is done during the back projection. Computer simulations are shown, both with the center of rotation shift uncorrected and corrected.

Algorithms

137Cs dosimetry table for asymmetric source.

A common 137Cs brachytherapy source has a 2-cm physical length and 1.38-cm active length. The active length is not symmetric with respect to the source center because one source end contains an eyelet. Current dose rate tables assume a symmetric source loading with respect to the source center. A computer program was written to calculate an asymmetric distribution using the manufacturers' source specifications. Corrections were made for attenuation and obliquity through the source materials. Dose rate values in cGy/h for a 137Cs source equivalent to 1 mg of 226Ra are shown as a function of the radius from the source center and angle from the source end containing the eyelet. Dose rate values in the table were confirmed by ferrous sulfate measurements using small volumes. The table values agree with published values at points more distant than a few cm and lying at an angle such that the asymmetry of the source loading has its minimum influence.

Brachytherapy