Influence of the antagonist material on the wear of different composites using two different wear simulation methods.

OBJECTIVES: The aim of the study was to evaluate two ceramic materials as possible substitutes for enamel using two wear simulation methods, and to compare both methods with regard to the wear results for different materials. METHODS: Flat specimens (OHSU n=6, Ivoclar n=8) of one compomer and three composite materials (Dyract AP, Tetric Ceram, Z250, experimental composite) were fabricated and subjected to wear using two different wear testing methods and two pressable ceramic materials as stylus (Empress, experimental ceramic). For the OHSU method, enamel styli of the same dimensions as the ceramic stylus were fabricated additionally. Both wear testing methods differ with regard to loading force, lateral movement of stylus, stylus dimension, number of cycles, thermocycling and abrasive medium. In the OHSU method, the wear facets (mean vertical loss) were measured using a contact profilometer, while in the Ivoclar method (maximal vertical loss) a laser scanner was used for this purpose. Additionally, the vertical loss of the ceramic stylus was quantified for the Ivoclar method. The results obtained from each method were compared by ANOVA and Tukey's test (p<0.05). To compare both wear methods, the log-transformed data were used to establish relative ranks between material/stylus combinations and assessed by applying the Pearson correlation coefficient. RESULTS: The experimental ceramic material generated significantly less wear in Tetric Ceram and Z250 specimens compared to the Empress stylus in the Ivoclar method, whereas with the OHSU method, no difference between the two ceramic antagonists was found with regard to abrasion or attrition. The wear generated by the enamel stylus was not statistically different from that generated by the other two ceramic materials in the OHSU method. With the Ivoclar method, wear of the ceramic stylus was only statistically different when in contact with Tetric Ceram. There was a close correlation between the attrition wear of the OHSU and the wear of the Ivoclar method (Pearson coefficient 0.83, p=0.01). SIGNIFICANCE: Pressable ceramic materials can be used as a substitute for enamel in wear testing machines. However, material ranking may be affected by the type of ceramic material chosen. The attrition wear of the OHSU method was comparable with the wear generated with the Ivoclar method.

Aluminum Silicates↗

Vaporization of Hg from Hg-in amalgams during setting and after abrasion.

OBJECTIVE: The aim of this study was to determine if Hg vaporization during setting and after abrasion of amalgams could be reduced by adding indium to Hg prior to trituration. METHODS AND MATERIALS: Hg-In alloys (0,5,10,15 wt% In) were triturated with commercial amalgam alloys (Tytin, Kerr; Artalloy, Degussa; Sybraloy, Kerr) and condensed into cylinders (4 x 8 mm). In one experiment, Hg release during setting was measured in air (37 degrees C) with a Jerome 431 Hg analyzer (n = 4). In a second experiment, amalgams aged two months were uniformly abraded on wet #600 SiC, blotted dry, and Hg release was measured in air (22 degrees C) for 30 min with a Jerome 411 Hg analyzer (n = 6). Total Hg was determined by integration (ng/mm2). Results were compared by ANOVA and Tukey's test (alpha = 0.05). RESULTS: Indium reduced Hg release from amalgams during setting. Amalgams ceased Hg release within 5 h. Indium did not reduce Hg release from abraded, set amalgams except Artalloy w/15% In. SIGNIFICANCE: Coupled with our previous studies, this work shows that 5-15 wt% indium can be added to effectively reduce Hg release during setting, but not after abrasion of set amalgams.

Air Pollution, Indoor↗

Dissolution of mercury from amalgam into saline solution.

Dissolution of mercury from amalgams and some intermetallic compounds found in the amalgam structure, such as gamma 1, gamma 2, and beta 1, was examined during one week of aging in 0.9% NaCl solution at 37 degrees C. The amount of mercury released from gamma 1 (30.2 micrograms/cm2) was at least 13 times that released from amalgam (0.5-2.2 micrograms/cm2) and five times that released from beta 1(5.7 micrograms/cm2). Gamma 2 released the least amount of mercury (0.46 micrograms/cm2). The study revealed that as high as 55% of the mercury ions liberated from the amalgams and the amalgam phases was adsorbed onto the walls of the vials in which the specimens were aged.