PubMed HealthSearch

Biomedical subjects

J Fetter

Publications and source records attributed to J Fetter.

At least 19 recordsLinked to original sources

Prehospital discharge defibrillation testing in ICD recipients: a prospective study based on cost analysis.

Prehospital discharge defibrillation testing is often performed to verify the function of newly implanted cardioverter defibrillators (ICDs). To determine whether elimination of predischarge testing could reduce costs without placing patients at additional risk, 31 patients were randomized in this prospective clinical evaluation to either receive or not receive a predischarge ICD defibrillation test. Expenses associated with postimplant care was the primary endpoint. All patients underwent induction of ventricular fibrillation after 6 months to evaluate ICD function. The groups were well matched in terms of patient characteristics, initial lead implant parameters, and defibrillation thresholds. Elimination of prehospital discharge testing resulted in a savings of $1,800/patient after 6 months, with no difference between groups in terms of ICD complication rates or unanticipated hospital admissions. Further studies are needed to better define the most appropriate time to assess defibrillation thresholds in the first year after implantation.

Aged

Physiologic cardiac pacing in patients with contemporary implantable cardioverter-defibrillators.

Contemporary implantable cardioverter-defibrillators (ICD) incorporate single-chamber ventricular pacing capability. However, because poor ventricular function and/or congestive heart failure is common in the ICD population, the provision of more "physiologic" pacing modes has been receiving increased attention. To evaluate the potential impact of ICDs with physiologic pacing features, we assessed the frequency with which atrial-based pacing modes with or without rate responsiveness are currently used in ICD recipients. Further, we characterized those clinical variables at initial ICD implant that tended to be associated with subsequent need for physiologic pacing. Clinical findings were reviewed in 250 consecutive patients who received ICDs with VVI pacing capability at the University of Minnesota Cardiac Arrhythmia Center between January 1991 and February 1997. Adjunctive physiologic pacing was undertaken in 35 patients (14%): 13 before or at the same time as their ICD, and 22 within a mean of 2.5 years after initial ICD surgery. A history of atrial tachyarrhythmia before ICD implantation (p <0.0001) and treatment with antiarrhythmic drugs at the time of ICD surgery (p <0.05) were predictors of subsequent need for physiologic pacing. The type of presenting ventricular tachyarrhythmia and electrophysiologic parameters (such as the HV interval and the shortest atrial pacing cycle length associated with 1:1 anterograde atrioventricular conduction) were not associated with a subsequent decision to implant a physiologic pacing system. Thus, we conclude that despite the need to implant a second device, physiologic pacing is currently used in an important subset of ICD recipients. Further, certain clinical features at time of ICD implant appear to characterize these patients and may prove helpful in patient selection for the next generation "dual-chamber" ICD.

Adolescent

Clinical experience with Thera DR rate-drop response pacing algorithm in carotid sinus syndrome and vasovagal syncope. The International Rate-Drop Investigators Group.

This study examined the effectiveness of cardiac pacing using the Thera DR rate-drop response algorithm for prevention of recurrent symptoms in patients with carotid sinus syndrome (CSS) or vasovagal syncope. The algorithm comprises both diagnostic and treatment elements. The diagnostic element consists of a programmable "window" used to identify heart rate changes compatible with an evolving neurally mediated syncopal episode. The treatment arm consists of pacing at a selectable rate and for a programmable duration. Forty-three patients (mean age 53 +/- 20.4 years) with CSS alone (n = 8), CSS in conjunction with vasovagal syncope (n = 4), or vasovagal syncope alone (n = 31) were included. Thirty-nine had recurrent syncope, while the remaining four reported multiple presyncopal events. Prior to pacing, 40 +/- 152 syncopal episodes (range from 1 to approximately 1,000 syncopal events) over the preceding 56 +/- 84.5 months. Postpacing follow-up duration was 204 +/- 172 days. Three patients have been lost to follow-up and in one patient the algorithm was disabled. Among the remaining 39 individuals, 31 (80%) indicated absence or diminished frequency of symptoms, or less severe symptoms. Twenty-three patients (23/29, or 59%) were asymptomatic with respect to syncope or presyncope. Sixteen patients had symptom recurrences. Of these, seven experienced syncope (7/39, or 18%) and 9 (29%) had presyncope: the majority of patients with recurrences (6/7 syncope and 7/9 presyncope) were individuals with a history of vasovagal syncope. Consequently, although symptoms were observed during postpacing follow-up, they appeared to be of reduced frequency and severity. Thus, our findings suggest that a transient period of high rate pacing triggered by the Thera DR rate-drop response algorithm was beneficial in a large proportion of highly symptomatic patients with CSS or vasovagal syncope.

Adolescent

Fatty acids stimulate activity and restore respiratory control in a proton channel mutant of cytochrome c oxidase.

(1) Removal of a carboxyl at residue 132 of subunit I of Rhodobacter sphaeroides cytochrome c oxidase significantly inhibits electron transfer and makes proton pumping undetectable [Fetter et al. (1995) Proc. Natl. Acad. Sci. USA 92, 1604-1608]. When reconstituted into phospholipid vesicles (COV), wild-type oxidase shows respiratory control that is partially released by either valimomycin or nigericin and fully released by the two ionophores combined. Under the same conditions, the D132A mutant COV show anomalous ionophore responses, including inhibition by valinomycin or by CCCP. Nevertheless, oxidase activity results in development of a similar membrane potential in COV containing either wild-type or D132A oxidase, and the ionophore responses of the membrane potential are similar for both enzymes. (2) Long chain fatty acids such as arachidonic acid, but not fatty alcohols, stimulate steady-state electron transfer activity 3-7-fold, with either detergent-solubilized (purified) D132A oxidase or the reconstituted form. The effect is specific for this mutant and is not seen with wild-type or other mutants of similar overall activity. Arachidonate-treated D132A COV show normal ionophore responses to valinomycin and nigericin and full release of respiration in presence of both ionophores or of CCCP. Thus, arachidonate and some other fatty acids abolish the ionophore anomalies seen when the D132A enzyme is reconstituted in their absence. (3) Fatty acid addition does not restore proton pumping, likely because fatty acids also induce proton permeability and some degree of uncoupling. A model of D132A function is presented and possible roles for the fatty acids in 'chemical rescue' of the mutant are discussed.

Alcohols

Termination and acceleration of ventricular tachycardia with autodecremental pacing, burst pacing, and cardioversion in patients with an implantable cardioverter defibrillator. Multicenter PCD Investigator Group.

This multicenter study reports the outcome of ventricular tachycardia (VT) therapy (conversion or acceleration) and the relationship to initial tachycardia cycle length and other clinical variables using an implantable device with the capability of autodecremental or burst pacing, cardioversion, and defibrillation. The device was implanted in 444 patients (mean age 58 +/- 15 years) with 1,240 episodes of VT induced with noninvasive programming and reported in a multicenter database. Only the first sequence attempted for conversion by pacing or cardioversion was assessed, and cardioversion energies were 0.2-5 J. Autodecremental pacing was used to treat 700 induced episodes of VT during titration of pacing therapies (57% converted and 12% accelerated), burst pacing to treat 357 episodes (49% converted under 11% accelerated), and cardioversion to treat 183 episodes (82% converted and 4% accelerated). Cardioversion was the most effective treatment and had the lowest acceleration rate. Shorter VT cycle lengths were more likely to accelerate with burst pacing and longer VT cycle lengths to convert with both burst and autodecremental pacing. Patients with higher ejection fractions were more likely to convert with autodecremental and burst pacing. Use of cardioversion, higher ejection fraction, absence of unrepaired aneurysm, longer VT cycle lengths, coronary artery disease, and use of autodecremental pacing predicted conversion. Lower ejection fraction and VT cycle lengths < or = 300 msec predicted tachycardia acceleration.

Adult

A loop between transmembrane helices IX and X of subunit I of cytochrome c oxidase caps the heme a-heme a3-CuB center.

Site-directed mutants were prepared of four consecutive and highly conserved residues (His-411, Asp-412, Thr-413, Tyr-414) of an extramembrane loop that connects putative transmembrane helices IX and X of subunit I of Rhodobacter sphaeroides cytochrome c oxidase. The modified enzymes were purified and analyzed by optical, resonance Raman, FTIR, and EPR spectroscopies. Consistent with our recent model in which both hemes are ligated to histidines of helix X [Hosler, J. P., et al. (1993) J. Bioenerg. Biomembr. 25, 121-136], substitutions for three of these four residues cause perturbations of either heme a or heme a3. Resonance Raman spectra of the mutant Y414F demonstrate that Tyr-414 does not participate in a hydrogen bond with the heme a formyl group, but its alteration does result in a 5-nm red-shift of the alpha-band of the visible spectrum, indicating proximity to heme a. The mutant D412N shows changes in resonance Raman and FTIR difference spectra indicative of an effect on the proximal ligation of heme a3. Changing His-411 to alanine has relatively minor effects on the spectral and functional properties of the oxidase; however, FTIR spectra reveal alterations in the environment of CuB. Conversion of this residue to asparagine strongly disrupts the environment of heme a3 and CuB and inactivates the enzyme. These results suggest that His-411 is very near the heme a3-CuB pocket. We propose that these residues form part of a cap over the heme a-heme a3-CuB center and thus are important in the structure of the active site.

Amino Acid Sequence

Low-energy transvenous cardioversion defibrillation of atrial tachyarrhythmias in the canine: an assessment of electrode configurations and monophasic pulse sequencing.

Prevention of recurrent atrial fibrillation and flutter remains a difficult clinical problem. Consequently, development of an easily implantable automatic atrial cardioverter defibrillator is appealing. In this context we have examined the feasibility of intracavitary low-energy shocks delivered via transvenously positioned electrodes for termination of induced atrial tachyarrhythmias in canine models. This study extends these observations with use of single-pathway (5 msec pulse duration) and dual-pathway sequential (5/5 msec, 0.2 msec separation) shocks of varying leading edge voltages (100 to 400 V) in a closed-chest canine talc-pericarditis model. Bipolar 9.5 French electrode catheters (electrode surface areas, 0.62 cm2) were positioned at the superior vena cava-right atrium (SVC-RA) junction (labeled SVC) and right ventricular (RV) apex, with a subcutaneous plate over the chest wall. For single-pathway shocks, overall treatment effectiveness was comparable among the three vectors tested (RV apex to SVC, 35%; RV apex to subcutaneous plate, 17%; and SVC to subcutaneous plate, 35%). Furthermore, there was no evident relationship between leading edge voltage and shock effectiveness. In contrast, although each of the dual-pathway shock vector combinations tested also showed similar overall effectiveness, there was an apparent dose-response effect as leading edge voltage increased. The SVC (common) to RV apex (pulse 1) and subcutaneous plate (pulse 2) achieved 60% effectiveness at 400 V (approximately 4 joules). Thus this study provides additional evidence favoring feasibility of low-energy transvenous atrial cardioversion defibrillation. However, further refinement of energy delivery is essential for the implantable automatic atrial cardioverter defibrillator concept to become clinically accepted.

Animals

Late follow-up of dual-chamber rate-adaptive pacing.

Dual-chamber pacing systems with sensor-based rate-adaptive capability (DDDR pacemakers) provide paced patients with the potential benefits of both a reliable chronotropic response and maintenance of atrioventricular (AV) synchrony. However, there is concern that clinical and programming complexities may necessitate frequent reprogramming of pacemakers from the DDDR mode to less physiologic pacing modes (in particular VVI or VVIR). Consequently, this study assessed the stability of pacing-mode programming, and the factors affecting pacing-mode selection in patients with a DDDR-capable pacing system. Clinical status during follow-up (18.2 +/- 6.7 months) was assessed in 75 patients. Principal diagnoses providing an indication for pacing were: (1) AV block alone, 18 of 75 patients (24%); (2) sick sinus syndrome alone, 41 (55%); and (3) combined AV block and sick sinus syndrome, 16 (21%). Twenty-three patients had history of atrial tachyarrhythmias. At implantation, 66 devices (88%) were programmed to DDDR mode, 7 (9%) to DDD, and 2 (3%) to DVIR. At last follow-up, the respective distribution of programmed modes was 83% DDDR, 10% DDD, 4% DVIR and 3% VVIR. During the study, the initial pacing mode remained unchanged in 54 patients (72%) and needed modification in 21 (28%). Of the latter 21 patients, atrial tachycardia was the basis for a programming change in 11 (52%), of whom 8 had history of atrial tachycardias. In general, postimplant atrial arrhythmia occurrences proved controllable, and ultimately return to a rate-adaptive dual-chamber pacing mode (DDDR, DDD or DVIR) was achieved in most cases. The remaining reprogrammings were primarily to optimize hemodynamic benefit.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Insight into the active-site structure and function of cytochrome oxidase by analysis of site-directed mutants of bacterial cytochrome aa3 and cytochrome bo.

Cytochrome aa3 of Rhodobacter sphaeroides and cytochrome bo of E. coli are useful models of the more complex cytochrome c oxidase of eukaryotes, as demonstrated by the genetic, spectroscopic, and functional studies reviewed here. A summary of site-directed mutants of conserved residues in these two enzymes is presented and discussed in terms of a current model of the structure of the metal centers and evidence for regions of the protein likely to be involved in proton transfer. The model of ligation of the heme a3 (or o)-CuB center, in which both hemes are bound to helix X of subunit I, has important implications for the pathways and control of electron transfer.

Amino Acid Sequence

Cytochrome aa3 of Rhodobacter sphaeroides as a model for mitochondrial cytochrome c oxidase. Purification, kinetics, proton pumping, and spectral analysis.

Aerobically grown Rhodobacter sphaeroides synthesizes a respiratory chain similar to that of eukaryotes. We describe the purification of the aa3-type cytochrome c oxidase of Rb. sphaeroides as a highly active (Vmax > or = 1800 s-1), three-subunit enzyme from isolated, washed cytoplasmic membranes by hydroxylapatite chromatography and anion exchange fast protein liquid chromatography. The purified oxidase exhibits biphasic kinetics of oxidation of mammalian cytochrome c, similar to mitochondrial oxidases, and pumps protons efficiently (H+/e- = 0.7) following reconstitution into phospholipid vesicles. A membrane-bound cytochrome c is associated with the aa3-type oxidase in situ, but is removed during purification. The EPR spectra of the Rb. sphaeroides enzyme suggest the presence of a strong hydrogen bond to one or both of the histidine ligands of heme a. In other respects, optical, EPR, and resonance Raman analyses of the metal centers and their protein environments demonstrate a close correspondence between the bacterial enzyme and the structurally more complex bovine cytochrome c oxidase. The results establish this bacterial oxidase as an excellent model system for the mammalian enzyme and provide the basis for site-directed mutational analysis of its energy transducing function.

Animals

Derivatization of peptides to enhance ionization efficiency and control fragmentation during analysis by fast atom bombardment tandem mass spectrometry.

Novel and simple procedures for preparing ethyl-triphenylphosphonium derivatives of peptides are described. These procedures allow an ethyl-triphenylphosphonium moiety to be selectively attached to either the N- or C-terminus. The resulting derivatives contain a positive charge at a fixed position and have significant hydrophobic character. Modification of peptides by these chemical methods significantly enhances the efficiency of fast atom bombardment ionization, especially of hydrophilic peptides. Moreover, upon collisionally activated dissociation, the derivatized peptides generate a predictable series of sequence ions from either the C-terminus or the N-terminus, depending on the location of the ethyl-triphenylphosphonium moiety.

Amino Acid Sequence

A new steroid-eluting epicardial lead: experience with atrial and ventricular implantation in the immature swine.

The first study with investigational steroid epicardial leads was carried out in mature canine with prototype leads. Because the demand for epicardial leads is highest in small infants and the prototype steroid-eluting lead has been redesigned, this study was carried out in immature swine to evaluate the newly designed lead. Six immature swine (2 at 5 weeks of age and 4 at 6 weeks) underwent epicardial implantation of four porous platinized tip leads: one steroid and one nonsteroid on the right atrium; one steroid and one nonsteroid on the right ventricle. At implantation, the lead terminals were connected to a percutaneous access device subcutaneously placed in the right lateral neck. This allowed chronic measurements by using an insulated needle connected with a cable to the pacing systems analyzer. Measurements were obtained at implantation and weekly for 3 weeks. Compared to the nonsteroid atrial leads, the steroid atrial leads had lower mean thresholds (P less than 0.01) at 1, 2, and 3 weeks after implantation. The mean threshold values from ventricular steroid leads were also lower and exhibited little increase from implant with the highest mean threshold of only 1.02 V, however, a statistically significant difference between steroid and nonsteroid was not reached. This newly designed steroid epicardial lead provided favorable results for continual human clinical study.

Animals

An office-based exercise protocol for predicting chronotropic response of activity-triggered, rate-variable pacemakers.

Activity-triggered, rate-variable pacing systems offer a wide range of pacemaker patients the benefits of an appropriate paced chronotropic response. However, optimizing settings for these devices often entails treadmill exercise testing. To assess simpler procedures for predicting appropriate settings, pacing rates of "strapped-on" and implanted Activitrax pacemakers were evaluated during arm exercise, walk-in-place exercise and treadmill exercise (0% slope at 1.5, 2.0 and 3.0 mph). For exercise of similar duration, steady-state pacing rates of implanted devices during arm and walk-in-place exercise were lower than those achieved during treadmill exercise. Linear regression analysis resulted in the slope of these relations most closely approaching 1.0 for arm exercise at "low" activity threshold, while walk-in-place tended to result in slopes approaching 1.0 at all activity thresholds. Similarly, although strapped-on devices underestimated rates obtained with implanted devices, differences fell within a narrow range (-6 to -14%). Thus, in patients with implanted or strapped-on Activitrax pacemakers, relatively simple exercise procedures suitable for office or clinic environment may be useful to provide an estimate of pacing rates during physical activity, and may thereby facilitate selection of appropriate programmable settings.

Adult

Effects of extracorporeal shock wave lithotripsy on single chamber rate response and dual chamber pacemakers.

This study evaluated effects of extracorporeal shock wave lithotripsy on four models of Medtronic implantable cardiac pacemakers. In vitro testing consisted of: (1) unsynchronized pacemaker strapped on the patient with extracorporeal shock synchronized to the patient's native heart rate; and (2) pacemakers suspended alone in water 6 inches from the focal point, synchronizing the extracorporeal shock to pacemaker output. Unsynchronized shocks affected each model of pacemaker differently, i.e., single chamber constant rate pacemakers experienced extended periods of inhibition for more than three pacing cycles while activity-triggered rate response pacemakers exhibited rate increases to the upper rate setting. Dual chamber synchronous pacemakers exhibited intermittently a 59% decrease and a 20% increase in ventricular rate due to inhibition and triggering, respectively, from shock oversensing. Synchronized shocks did not alter the rate of single chamber constant rate pacemakers, but did cause the rate to increase to the upper rate setting for activity-triggered rate response pacemakers. The shock was synchronized to the initial atrial output from the dual chamber pacemaker and caused frequent inhibition of the ventricular stimulus when the ventricular-safety-pace (VSP) feature was programmed off. Programming VSP on reduced the incidence of ventricular inhibition resulting in near normal pacemaker operation. There was neither observable damage to pacemaker components nor spurious reprogramming of pacemaker parameters during the tests. Our studies with one manufacturer's pacemakers suggests that lithotripsy shock effects on implantable pacemakers can be tolerated provided: (1) the single chamber pacemaker is programmed to the demand constant rate modality; (2) the dual chamber pacemaker is programmed to VSP on or to the VVI mode; and (3) the pacemaker distance to the focal point is greater than 6 inches.(ABSTRACT TRUNCATED AT 250 WORDS)

Equipment Design

Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing.

A noninvasive procedure has been developed to assess effectiveness of activity-sensing rate response ventricular (VVIR) pacing systems in patients with implanted conventional fixed-rate ventricular (VVI) pacemakers capable of triggered mode operation (VVT). A VVIR pacemaker (activity threshold medium or low, rate response 6 to 10, upper rate 125 or 150 beats/min) was strapped to the chest wall (prepectoral area) of patients with previously implanted fixed-rate VVI pacemakers. In 17 of the 18 patients included in the study, the implanted pacemaker was capable of triggered mode operation (VVT). Triggering of the conventional pacemaker was achieved by reprogramming it to the VVT mode (high sensitivity, short refractory) and connecting the output of the "strapped-on" VVIR pacemaker (5 volts, 1.5-ms pulse width) to 2 standard cutaneous electrodes positioned so as to be in proximity to the implanted intracardiac electrode system. Patients underwent symptom-limited treadmill exercise tests during both VVI and VVIR pacing. Triggering conventional VVI pulse generators by a "strapped-on" VVIR pacing system proved feasible in 16 of 17 cases and improved overall heart rate response (fixed rate 86 +/- 22 vs VVIR 118 +/- 7 beats/min) and exercise duration (fixed rate 6.6 +/- 4.9 vs VVIR 10.1 +/- 4.8 minutes) (mean values for all patients studied during exercise testing). Triggering of a previously implanted permanent pacemaker by a strapped-on activity-triggered device may be useful to assess rate response pacing before implantation of a VVIR device in patients in whom elective pulse generator replacement is planned.

Adolescent

Contribution of atrioventricular synchrony to left ventricular systolic function in a closed-chest canine model of complete heart block: implications for single-chamber rate-variable cardiac pacing.

This study assessed the impact of atrioventricular (AV) synchrony on characteristics of left ventricular (LV) systolic function during ventricular pacing over a wide heart rate range in a conscious closed-chest canine model of complete AV block. Ten healthy adult dogs underwent thoracotomy during which complete AV block was created by formaldehyde injection, and paired ultrasonic sonomicrometers were positioned on the LV anterior-posterior minor axis. Following recovery from surgery, peak and end-diastolic LV transmural pressure, maximum dP/dt, stroke work, end-diastolic minor axis dimension, and maximum velocity of shortening, were quantitated at heart rates of 80, 100, 120, 140, and 160 beats per minute (bpm) during both ventricular pacing alone and AV sequential pacing with increasing AV intervals (0, 50, 100, 150, 200, 250, and 300 ms). Over the heart rate range tested, parameters of LV systolic function did not differ significantly during ventricular pacing with or without AV synchrony. For example, during ventricular pacing alone maximum LV dP/dt varied from 2110 +/- 70 mmHg/s to 2463 +/- 567 mmHg/s, a range essentially identical to that observed in the presence of AV synchrony. On the other hand, although the impact on LV performance of varying AV interval from 0 to 300 ms was small, differences tended to become more pronounced at higher pacing rates. At 80 bpm, neither stroke work nor maximum LV dP/dt were affected by change in AV interval, while at heart rates greater than or equal to 120 bpm both stroke work and LV dP/dt tended to maximize at AV intervals of 50 and 100 ms and thereafter declined.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Noninvasive conversion of a fixed-rate demand pacemaker to activity mode: a method for assessing the clinical effect of rate-responsiveness.

Some patients with fixed-rate demand pacemakers may benefit from conversion to a rate-responsive pacing system. In this report, we describe a technique by which the effect of rate-responsive pacing can be assessed before replacing the pacemaker system. An externally positioned activity-mode physiologic pulse generator was used to drive a previously implanted ventricular demand pacemaker programmed to the triggered mode. Comparison of exercise capacity under both conditions suggested a substantial benefit from rate-responsiveness.

Aged