Performance standards in positron emission tomography.

A standard set of performance measurements is proposed for use with positron emission tomographs. This set of measurements has been developed jointly by the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. The measurements include tests of spatial resolution, scatter fraction, sensitivity, count rate losses and randoms, uniformity, scatter correction, attenuation correction, and count rate linearity correction.

Humans↗

Stable xenon CT blood flow mapping for evaluation of patients with extracranial-intracranial bypass surgery.

Xenon computerized tomography (Xe CT) blood flow studies were conducted in 25 patients referred for a possible extracranial-intracranial bypass procedure for occlusive vascular disease in one or more extra- or intracranial vessels. These studies were helpful in selecting eight candidates for surgery. The Xe CT studies were performed at one or two brain levels using a prototype Xe CT system for measurement of cerebral blood flow which was designed in collaboration with the General Electric Co., and adapted for the GE 9800 scanner. In those patients selected to undergo operation, Xe CT demonstrated compromise of flow reserve regionally, globally, and/or in the watershed area. All eight patients who underwent the procedure showed a favorable clinical response postoperatively, and seven had a dramatic increase in flow. The 17 patients whose baseline CT studies showed no reduction of flow with the Xe CT method were not selected for surgery. All 25 patients have remained neurologically stable to date. Case studies of three of the eight patients undergoing bypass surgery are presented. This limited but consistent experience suggests that Xe CT blood flow mapping makes possible the recognition of brain regions in which flow reserves are compromised. This is due to the relatively high degree of spatial resolution that this technique provides and to the fact that mapping can be correlated directly with the anatomy. Used in combination with a careful clinical examination and an accurate medical history, this study method appears to be a useful guide in the selection of patients who are most at risk from hemodynamic instability and those who are most likely to benefit from flow-augmentation surgery.

Aged↗

Xenon/CT blood flow mapping of the kidney and liver.

A noninvasive technique for measuring blood flow by xenon-enhanced X-ray transmission CT has been developed and reported quite extensively in recent years. In this method nonradioactive xenon gas is inhaled, and the temporal changes in radiographic enhancement produced by the inhalation are measured by sequential CT. Time-dependent xenon concentration within various tissue segments is used to derive local blood flow maps. The method has been amply discussed in relation to assessment of local cerebral blood flow. Its application to other body organs is explored in this paper, in which results from six preliminary blood flow studies in the liver and kidneys of nonhuman primates are reported. Blood flow in renal cortex ranged from 150 to 280 ml/100 cc/min and hepatic tissue perfusion from 80 to 120 ml/100 cc/min. The advantages and limitations of the method in such applications are discussed.

Animals↗

Fully three-dimensional positron emission tomography.

Fully three-dimensional positron emission tomography is considered and a reconstruction algorithm derived. The reconstruction problem is formulated mathematically as a three-dimensional convolution integral of a point spread function with an unknown positron activity distribution and is solved by Fourier transform methods. Performance of the algorithm is evaluated using both simulated phantom data produced by a Monte Carlo computer program and phantom data obtained from the University of Chicago/Searle Positron Camera. It is concluded that the method is computationally feasible and results in accurate reconstructions.

Mathematics↗

Correction for field nonuniformity in scintillation cameras through removal of spastial distortion.

A method to correct for the spatial distortions of gamma cameras has been developed. The method consists of two parts: measuring spatial distortions and repositioning events during accumulation. Distortions are measured using a pattern consisting of parallel slits on 15-mm centers with slit-pattern images obtained in two orthogonal orientations. Slit locations are used to determine X and Y displacements. In repositioning camera events, X and Y event coordinates are digitized and correction displacements added. The procedure is implemented in hardware that replositions each event in real time without introducing additional dead time. Distortion removal offers considerable advantage over other uniformity-improvement schemes, since it correctly compensates for the major cause of nonuniformity, spatial distortion. The method may be used for quantitative studies, because it does not change the number of detected events.