The extension of the concept of tissue-air ratios (TAR) to high-energy x-ray beams.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J G Holt.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
da Silva, G. A. Nigel (Iowa State University, Ames), and John G. Holt. Numerical taxonomy of certain coryneform bacteria. J. Bacteriol. 90:921-927. 1965-An electronic computer was used to sort 32 strains of coryneforms into groups with the tree-sort program. The similarity values obtained in this procedure were then used to construct a dendrogram depicting the phenetic resemblance among the taxa. The results indicated that all the phytopathogens studied were sufficiently distinct from the type species, Corynebacterium diphtheriae, to be excluded from the genus Corynebacterium. The grouping of some of the phytopathogens with Microbacterium lacticum is discussed. C. fascians appeared so distinct from the other strains studied that it should probably be excluded from the Corynebacteriaceae. The phenetic resemblance of Brevibacterium linens and Arthrobacter globiformis was emphasized, and the new combination, Arthrobacter linens, was proposed. In addition, because of distinct dissimilarity from the type species, it would seem desirable to exclude Arthrobacter tumescens from the genus Arthrobacter. The justification for classifying Kurthia zopfii in a family separate from the Corynebacteriaceae would appear to be open to serious question. It was concluded that the present taxonomic positions of Listeria monocytogenes, Cellulomonas biazotea, and Cellulomonas fimi are satisfactory.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The most commonly used method of calibrating high-energy photon or electron beams consists in converting cavity ionization to dose by the application of the appropriate Clambda or CE multipled by the 60Co correction factor. The correct interpretation of calibration data for pulsed photon or electron beams requires a knowledge of the charge collection efficiencies of the ionization chambers used. The results are presented of efficiency measurements for both pulsed and continuous beams made with these chambers: 0.6-cm3 Farmer, 0.5-cm3 Spokas, 3-cm3 Shonka, 1-cm3 PTW, and 1-cm3 Memorial pancake. The dependence of collection efficiency on collection voltage, dose rate, and dose per pulse is demonstrated. These results are shown to agree with Boag's formulas for collection efficiency. Attention is drawn to the fact that several kinds of dosimeters provide only minimal collection voltages for efficient collection of charge at high dose rates, especially in Linac electron beams. It is recommended to check the collection efficiency of chambers which are to be used at high dose rates, and a simple method for this purpose is described.
Explore the source record for details and available documents.
The calibration of a cobalt-60 beam in a phantom with an ion chamber, which has been calibrated with respect to exposure, requires the use of a displacement correction factor which essentially corrects the photon fluence for the attenuation and scatter when the chamber with buildup cap is removed and replaced by phantom material. To determine the displacement factor, Ac, a special set of cylindrical ionization chambers with various volumes were constructed out of polystyrene. Tissue-air ratios were measured with these chambers for cobalt-60 gamma rays in a polystyrene phantom, and the ratio Ac/Aeq was experimentally determined. In order to calculate Ac from this ratio, Aeq was determined also. It was found that Ac depended on chamber diameter only, and not on field size or depth. A value of 0.990 for Aeq is recommended and a table of Ac for chambers of different outer diameters is included.
Charged particles penetrating a medium are repeatedly deflected from their line of motion by coulomb interactions with target nuclei. This physical feature should be included in the calculation of dose distributions when the irradiated medium contains small inhomogeneities. We use the mean path taken by particles in homogeneous media to represent their motion through inhomogeneous materials. This procedure adapts wht small angle multiple scattering formalism to yield manageable, approximate solutions when a medium contains arbitrarily composed inhomogeneities. To promote the development of this procedure into an electron beam treatment planning program, we discuss the salient features which arise in connection with electron beam inhomogeneity calculations. We use a solid phantom containing an air cavity just below its surface as a particular example of a small inhomogeneity. We discuss qualitatively and quantitatively the dose distributions which result from their irradiation with an 11-MeV electron beam.
Explore the source record for details and available documents.