PubMed Health⌕ Search

Biomedical subjects

J G Miller

Publications and source records attributed to J G Miller.

At least 19 recordsLinked to original sources

Adherence to antiretroviral therapy in rural persons living with HIV disease in the United States.

The current study delineated patterns and predictors of adherence to antiretroviral therapy in 329 persons living with HIV disease in rural areas of 12 US states. Participants provided self-report data on patterns of HIV medication adherence, reasons for missing medication doses, psychological symptomatology, life-stressor burden, social support, ways of coping, coping self-efficacy, the quality of their relationship with their main physician, and barriers to health care and social services. Based on adherence data collected via retrospective, self-report assessment instruments, only 50% of participants adhered consistently to antiretroviral therapy regimens in the past week. Consistent adherence was more common in White participants, persons who had progressed to AIDS, and 'native infections' (i.e. persons who were born, raised, and infected in their current place of residence). Logistic regression analyses indicated that consistent adherence was reported by persons who drank less alcohol, had a good relationship with their main physician, and engaged in more active coping in response to HIV-related life stressors. As the number of rural persons living with HIV disease continues to increase, research that identifies correlates of non-adherence and conceptualizes approaches to optimize adherence in this group is urgently needed.

Adolescent↗

Fingerprinting of polysaccharides attacked by hydroxyl radicals in vitro and in the cell walls of ripening pear fruit.

Hydroxyl radicals (*OH) may cause non-enzymic scission of polysaccharides in vivo, e.g. in plant cell walls and mammalian connective tissues. To provide a method for detecting the action of endogenous *OH in vivo, we investigated the products formed when polysaccharides were treated with *OH (generated in situ by ascorbate-H(2)O(2)-Cu(2+) mixtures) followed by NaB(3)H(4). Treatment with *OH increased the number of NaB(3)H(4)-reacting groups present in citrus pectin, homogalacturonan and tamarind xyloglucan. This increase is attributed partly to the formation of glycosulose and glycosulosuronic acid residues, which are then reduced back to the original (but radioactive) sugar residues and their epimers by NaB(3)H(4). The glycosulose and glycosulosuronic acid residues were stable for >16 h at 20 degrees C in ethanol or buffer (pH 4.7), but were destroyed in alkali. Driselase-digestion of the radiolabelled polysaccharides yielded characteristic patterns of (3)H-products, which included galactose and galacturonate from pectin, and isoprimeverose, galactose, glucose and arabinose from xyloglucan. Pectin yielded at least eight (3)H-labelled anionic products, separable by electrophoresis at pH 3.5. The patterns of radioactive products form useful 'fingerprints' by which *OH-attacked polysaccharides may be recognized. Applied to the cell walls of ripening pear (Pyrus communis) fruit, the method gave evidence for progressive *OH radical attack on polysaccharides during the softening process.

Cell Wall↗

Characteristics of xyloglucan after attack by hydroxyl radicals.

It has been proposed that plant cell-wall polysaccharides are subject in vivo to non-enzymic scission mediated by hydroxyl radicals (-*OH). In the present study, xyloglucan was subjected in vitro to partial, non-enzymic scission by treatment with ascorbate plus H(2)O(2), which together generate -*OH. The partially degraded xyloglucan appeared to contain ester bonds within the backbone, as indicated by an irreversible decrease in viscosity upon alkaline hydrolysis. Aldehyde and/or ketone groups were also introduced into the polysaccharide by -*OH-attack, as indicated by staining with aniline hydrogen-phthalate and by reaction with NaB(3)H(4). The introduction of ester and oxo groups supports the proposed sequence of reactions: (a) -*OH-mediated H-abstraction to produce a carbon-centred carbohydrate radical; (b) reaction of the latter with O(2); and (c) elimination of a hydroperoxyl radical (HO(2)*-). When the partially degraded xyloglucan was reduced with NaB(3)H(4) followed by acid hydrolysis, several 3H-aldoses were detected ([3H]galactose, [3H]xylose, [3H]glucose, [3H]ribose and probably [3H]mannose), in addition to unidentified 3H-products (probably including anhydroaldoses). 3H-Alditols were undetectable, showing that few or no conventional reducing termini were introduced. Digestion of the NaB(3)H(4)-reduced, partially degraded xyloglucan with Driselase released 25 times more [3H]Xyl-alpha-(1-->6)-Glc than Xyl-alpha-(1-->6)-[3H]Glc, suggesting that the xylose side-chains of the xyloglucan had been more heavily attacked by -*OH than the glucose residues of the backbone. The radioactive xyloglucan was readily digested by cellulase, yielding 3H-products in the hepta- to nonasaccharide range. A fingerprinting strategy for identifying -*OH-attacked xyloglucan in plant cell walls is proposed.

Ascorbic Acid↗

Transmural variation of myocardial attenuation measured with a clinical imager.

The objective of this study was to quantify the transmural variation in attenuation for the septal and lateral walls of the heart. Our approach was to utilize a commercially available ultrasonic imaging system to acquire images of excised sections of eight sheep hearts with an orientation similar to that encountered in the apical four-chamber view. The measured values (mean +/-SE) of the slope of attenuation for the transmural regions of the septum are: 1.40 +/-0.11, 0.99 +/-0.09, and 1.85 +/-0.16 (dB/cm/MHz) for the left subendocardial, midmyocardial, and right subendocardial zones, respectively. The analogous data from the lateral wall are: 1.42 +/-0.11, 0.83 +/-0.07, and 1.20 +/- 0.16 (dB/cm/MHz) for the subendocardial, midmyocardial, and subepicardial zones, respectively. These data demonstrate that ultrasonic attenuation associated with the septum and the lateral wall, when imaged in a manner similar to that of the apical four-chamber view, is anisotropic.

Animals↗

Ultrasonic tissue characterization: review of an approach to assess hypertrophic myocardium.

It is well known that left ventricular hypertrophy is associated with increased cardiovascular morbidity and mortality. Recently, there has been considerable interest in the application and refinement of noninvasive diagnostic techniques for identification of myocardial tissue composition to permit differentiation between left ventricular hypertrophy that may be associated with irreversible, and therefore, possibly adverse, collagen accumulation ("pathological hypertrophy") as opposed to the type of possibly "benign" hypertrophy devoid of such characteristics (i.e., "physiological hypertrophy"). We review the current state of knowledge in the application of ultrasonic tissue characterization that addresses this question with respect to left ventricular myocardium.

Cardiomyopathies↗

Transmural variation of myocardial attenuation and its potential effect on contrast-mediated estimates of regional myocardial perfusion.

Promising technical developments suggest that it may be feasible to use contrast echocardiography to estimate regional myocardial perfusion. Although the optimal approach has not yet been determined, the use of a nonlinear (harmonic) response of the contrast agent is common to several recent advances. The purpose of this article is to delineate the relation between the anisotropic (angle-dependent) ultrasonic attenuation of the myocardium through which the sound wave has propagated and the regional, nonlinear response of the contrast agent. Apparent perfusion will be modulated by this regionally varying, path-dependent attenuation, which is determined by the local angle between the propagating sound wave and the myofiber orientation. We illustrate the potential magnitude of the effect of myocardial anisotropy for the apical 4-chamber view by examining propagation along the septum and the lateral wall. We present experimentally measured values of the attenuation of excised sheep myocardium, showing statistically significant differences in the attenuation in the mid wall compared with that in symmetrical zones to the left and right of the mid wall, reflecting the well-known myofiber orientations in these 3 regions. The nonlinear (harmonic) response of a contrast agent depends on the local pressure amplitude, which for a given mechanical index is determined by the attenuation accumulated along the path to the point where the regional perfusion is estimated.

Animals↗

Experimental validation of the use of Kramers-Kronig relations to eliminate the phase sheet ambiguity in broadband phase spectroscopy.

The technique of broadband phase spectroscopy proposed in 1978 by Sachse and Pao [J. Appl. Phys. 49, 4320-4327 (1978)] determines the phase velocity as a function of frequency from the Fourier transforms of a received reference and through-sample signal. Although quite successful, this approach can be influenced by an ambiguity in the phase velocity calculation which stems from the boundedness of the inverse tangent operation used to calculate phase. Several empirical approaches to resolve the phase ambiguity have been reported. An alternative approach that has not previously been considered appeals to the causal nature of the measurements. This article experimentally validates a method which uses the causally consistent Kramers-Kronig relations to eliminate the ambiguity in phase spectroscopy-derived phase velocity calculations. Broadband pulse and narrow-band tone burst measurements were performed on three gelatin-based phantoms containing different concentrations of graphite particles (0%, 10%, and 20% by volume). The phantoms were constructed to have attenuation coefficients which vary approximately linear-with-frequency, a dependence exhibited by many soft tissues. The narrow-band phase velocity measurements do not suffer from a phase ambiguity, and thus they serve as a "gold standard" against which the broadband phase velocity measurements are compared. The experimental results illustrate that using the Kramers-Kronig dispersion relations in conjunction with phase spectroscopy-derived phase velocity measurements is an effective means by which to resolve the phase sheet ambiguity in broadband phase spectroscopy.

Fourier Analysis↗

Assessing animal care and use programs internationally.

As international collaborations become commonplace, new issues arise concerning the potentially variable quality of laboratory animals. The Associate Director and the Director of AAALAC International discuss efforts to harmonize facility procedures and practices of animal care and use globally.

Journal Article↗

Contrast echocardiography: current and future applications.

Recent updates in the field of echocardiography have resulted in improvements in image quality, especially in those patients whose ultrasonographic (ultrasound) evaluation was previously suboptimal. Intravenous contrast agents are now available in the United States and Europe for the indication of left ventricular opacification and enhanced endocardial border delineation. The use of contrast enables acquisition of ultrasound images of improved quality. The technique is especially useful in obese patients and those with lung disease. Patients in these categories comprise approximately 10% to 20% of routine echocardiographic examinations. Stress echocardiography examinations can be even more challenging, as the image acquisition time factor is critically important for accurate detection of coronary disease. Improvements in image quality with intravenous contrast agents can facilitate image acquisition and enhance delineation of regional wall motion abnormalities at the peak level of exercise. Recent phase III clinical trial data on the use of Optison and several other agents (currently under evaluation) have revealed that for approximately half of patients, image quality substantively improves, which enables the examination to be salvaged and/or increases diagnostic accuracy. For the "difficult-to-image" patient, this added information results in (1) enhanced laboratory efficiency, (2) a reduction in downstream testing, and (3) possible improvements in patient outcome. In addition, substantial research efforts are underway to use ultrasound contrast agents for assessment of myocardial perfusion. The detection of myocardial perfusion during echocardiographic examinations will permit the simultaneous assessment of global and regional myocardial structure, function, and perfusion-all of the indicators necessary to enable the optimal noninvasive assessment of coronary artery disease. Despite the added benefit in improved efficacy of testing, few data exist regarding the long-term effectiveness of these agents. Currently under evaluation are the clinical and economic outcome implications of intravenous contrast agent use for daily clinical decision making in a variety of patient subsets. Until these data are known, this document offers a preliminary synthesis of available evidence on the value of intravenous contrast agents for use in rest and stress echocardiography. At present, it is the position of this guideline committee that intravenous contrast agents demonstrate substantial value in the difficult-to-image patient with comorbid conditions limiting an ultrasound evaluation of the heart. For such patients, the use of intravenous contrast agents should be encouraged as a means to provide added diagnostic information and to streamline early detection and treatment of underlying cardiac pathophysiology. As with all new technology, this document will require updates and revisions as additional data become available.

Contrast Media↗

In vivo molecular imaging of stretch-induced tissue factor in carotid arteries with ligand-targeted nanoparticles.

Molecular imaging permits tissues to be functionally characterized by identification of specific cell-surface receptors with targeted contrast agents. In our study, a ligand-targeted acoustic nanoparticle system was used to identify the angioplasty-induced expression of tissue factor by smooth muscle cells within the tunica media. Pig carotid arteries were overstretched bilaterally with balloon catheters, treated with a tissue factor-targeted or a control nanoparticle system, and imaged with intravascular ultrasound (20 MHz) before and after treatment. Carotid wall acoustic reflectivities were unaffected by overstretch injury. Tissue factor-targeted nanoemulsion bound and increased the echogenicity of smooth muscle cells expressing tissue factor within the tunica media. The targeted emulsion increased the arterial wall gray scale (99.4+/-14.5; P<.05) relative to pretreatment (41.8+/-11.1, P<0.05) and the control gray scale (pre-emulsion: 49.3+/-9.5; post-emulsion: 43.7+/-6.4; P<.05). The area of acoustic enhancement appeared to coincide with expression of induced tissue factor in the tunica media confirmed by immunohistochemistry. We have demonstrated that this novel nanoemulsion can infiltrate into arterial walls after balloon injury and localize the expression of overstretch-induced tissue factor within pig carotid arteries. Molecular imaging and quantification of complex, biochemical change, such as tissue factor expression after angioplasty, may prove to be a prognostically important predictor of subsequent restenosis.

Acoustics↗

In vivo colocalization of xyloglucan endotransglycosylase activity and its donor substrate in the elongation zone of Arabidopsis roots.

We have developed a method for the colocalization of xyloglucan endotransglycosylase (XET) activity and the donor substrates to which it has access in situ and in vivo. Sulforhodamine conjugates of xyloglucan oligosaccharides (XGO-SRs), infiltrated into the tissue, act as acceptor substrate for the enzyme; endogenous xyloglucan acts as donor substrate. Incorporation of the XGO-SRs into polymeric products in the cell wall yields an orange fluorescence indicative of the simultaneous colocalization, in the same compartment, of active XET and donor xyloglucan chains. The method is specific for XET, as shown by competition experiments with nonfluorescent acceptor oligosaccharides, by negligible reaction with cello-oligosaccharide-SR conjugates that are not XET acceptor substrates, by heat lability, and by pH optimum. Thin-layer chromatographic analysis of remaining unincorporated XGO-SRs showed that these substrates are not extensively hydrolyzed during the assays. A characteristic distribution pattern was found in Arabidopsis and tobacco roots: in both species, fluorescence was most prominent in the cell elongation zone of the root. Proposed roles of XET that include cell wall loosening and integration of newly synthesized xyloglucans could thus be supported.

Arabidopsis↗

The extracellular matrix is an important source of ultrasound backscatter from myocardium.

Ultrasound tissue characterization with measurement of backscatter has been employed in numerous experimental and clinical studies of cardiac pathology, yet the cellular components responsible for scattering from cardiac tissues have not been unequivocally identified. This laboratory has proposed a mathematical model for myocardial backscatter that postulates the fibrous extracellular matrix (ECM) as a significant determinant of backscatter. To demonstrate the importance of ECM, this group sought to determine whether measurements of backscatter from the isolated ECM could reproduce the known directional dependence, or anisotropy of backscatter, from intact cardiac tissues in vitro. Segments of left ventricular free wall from ten formalin fixed porcine hearts were insonified at 50 MHz, traversing the heart wall from endo- to epicardium to measure the anisotropy of myocardial backscatter, defined as the difference between peak (perpendicular to fibers) and trough (parallel to fibers) backscatter amplitude. The tissue segments were then treated with 10% NaOH to dissolve all of the cellular components, leaving only the intact ECM. Scanning electron micrographs (SEM) were obtained of tissue sections to reveal complete digestion of the cellular elements. The dimensions of the residual voids resulting from cell digestion were approximately the diameter of the intact myocytes (10-30 microm). These samples were reinsonified after seven days of treatment to compare the anisotropy of integrated backscatter. The magnitude of anisotropy of backscatter changed from 15.4 +/- 0.8 to 12.6 +/- 1.1dB for intact as compared with digested specimens. Because digestion of the myocardium leaves only extracellular sources of ultrasonic scattering, and because the isolated ECM exhibits similar ultrasonic anisotropy as does the intact myocardium, it is concluded that there is a direct association between the ECM and the anisotropy of backscatter within intact tissue. Thus, it is suggested that ultrasonic tissue characterization represents a potentially clinically applicable method for delineating the structure and function of the ECM.

Animals↗

Broadband time-domain reflectometry measurement of attenuation and phase velocity in highly attenuating suspensions with application to the ultrasound contrast medium Albunex.

We describe a technique for broadband measurements of the attenuation coefficient and phase velocity of highly attenuating liquid suspensions. To validate the technique we apply it to the ultrasound contrast agent Albunex at concentrations ranging from 0.69 x 10(6) particles/mL to 364 x 10(6) particles/mL. These longitudinal wave measurements were performed on Albunex suspensions maintained at 37 degrees C in a special time-domain reflectometer designed and constructed in our laboratory. The frequency-dependent attenuation coefficients and phase velocities obtained in the reflectometer are compared to broadband through-transmission measurements of these same quantities, which were also performed in our laboratory. Although comparison data between the two techniques are only available at lower concentrations, the agreement is quite good and serves to validate the methods described in this paper.

Albumins↗

Cyclic variation of integrated backscatter: dependence of time delay on the echocardiographic view used and the myocardial segment analyzed.

To determine the influence of myocardial anisotropy in ultrasonic tissue characterization, we measured the time delay (and magnitude) of the cyclic variation of myocardial integrated backscatter from specific segments visualized in the 4 standard transthoracic echocardiographic views. The cyclic variation data in 10 myocardial regions were obtained from analyses of 2-dimensional integrated backscatter images from 23 healthy subjects. Resultant values (mean +/- SD) for the time delay were as follows: parasternal long-axis view: 1.08 +/- 0.17 (septum) and 1.00 +/- 0.14 (posterior wall); parasternal short-axis view: 1.03 +/- 0.16 (anterior septum), 1.03 +/- 0.14 (posterior wall), 2.22 +/- 0.71 (lateral wall), and 1.65 +/- 0.66 (posterior septum); apical 4-chamber view: 1.08 +/- 0.31 (septum) and 2.20 +/- 0.79 (lateral wall); and apical 2-chamber view: 1.68 +/- 0.62 (inferior wall) and 2.04 +/- 0.72 (anterior wall). Hence, results of this study indicate that myocardial ultrasonic characterization that uses the cyclic variation is influenced by the echocardiographic view and the specific segment of the left ventricle.

Adult↗

Dependence of "apparent" magnitude on the time delay of cyclic variation of myocardial backscatter.

The goal of this study was to determine if the "apparent" magnitude of the cyclic variation, defined as the difference between the values of integrated backscatter at end-diastole and end-systole, was dependent on the corresponding time delay. We measured the cyclic variation in four myocardial segments of the parasternal short-axis view in 23 healthy subjects. The "apparent" magnitude, actual magnitude, and time delay were compared for each segment. Measured time delays were: 2.22+/-0.71 (lateral wall); 1.65+/-0.66 (inferior septum); and approximately 1.0 for the anterior septum and posterior wall. Segments exhibiting large time delays (> 1.0) resulted in a reversal in sign of the "apparent" magnitude of cyclic variation in one instance, and underestimated the true magnitude in both cases. Thus, estimates of the "apparent" magnitude of the cyclic variation are dependent on the associated time delay, whereas a properly defined magnitude is not.

Adult↗

Broadband measurement of the scattering-to-attenuation ratio for Albunex at 37 degrees C.

The attenuation coefficient and backscatter coefficient of Albunex were measured over a wide range of concentrations and frequencies (at a temperature of 37 degrees C), and were used to calculate the scattering-to-attenuation ratio (STAR) value. Each of these quantities exhibited concentration dependence in agreement with predictions from simple scattering theory: the backscatter coefficient grew linearly with concentration, the power of the transmitted signal decreased exponentially with concentration due to attenuation, and the STAR was independent of concentration scaling. Because of the markedly differing concentration dependence, it is necessary to consider all of these quantities (not just the STAR value alone) when evaluating and comparing the potential efficacy of ultrasonic contrast agents.

Albumins↗

Effects of tissue anisotropy and contrast acoustic properties on myocardial scattering in contrast echocardiography.

In this study we explored the potential effects that tissue anisotropy, in conjunction with the acoustic properties of contrast, may have on quantitative measurements of myocardial perfusion with the use of ultrasonic contrast agents. We used a computer simulation of the parasternal short-axis view, based on previously measured values for the anisotropy of backscatter and attenuation of myocardium, to predict the backscattered energy from 18 specific regions within the heart before and after myocardial contrast perfusion. Results demonstrated a regional variation of contrast enhancement in the short-axis view and variations caused by incremental increases in contrast level for specific myocardial regions. Thus quantitative assessment of myocardial perfusion with contrast echocardiography is influenced by the anisotropic properties of the myocardium, and the resulting postcontrast image will depend on the interaction between tissue properties and contrast acoustic properties. The degree of myocardial enhancement caused by the presence of contrast may depend on the spatial position of the specific region investigated with respect to the transducer and the amount of contrast in the myocardium.

Anisotropy↗