Evaluation of the effect of uterine artery embolisation on menstrual blood loss and uterine volume.

OBJECTIVE: To evaluate the effect of uterine artery embolisation (UAE) on menstrual blood loss (MBL) and uterine volume in women with symptomatic uterine fibroids. DESIGN: Prospective observational study. SETTING: West of Scotland gynaecology and radiology departments. POPULATION: Fifty women (mean age 43 years) with symptomatic fibroids undergoing UAE between January 1999 and June 2003. METHODS: Women collected sanitary protection from one menses pre-embolisation and at regular intervals thereafter. This allowed objective measurement of MBL using the alkaline haematin technique. Uterine volume was calculated using magnetic resonance imaging (MRI) before and six months following embolisation. Interventional radiologists performed bilateral UAE. The Wilcoxon's signed rank test was used for statistical analysis of data. MAIN OUTCOME MEASURES: Post-embolisation MBL and uterine volume changes. RESULTS: Median pretreatment MBL was 162 mL (mean 234, range 9-1339). The median MBL decreased to 60 mL at 3 months (n= 34, range 0-767, P < 0.001), 70 mL at 6-9 months (n= 34, range 0-1283, P < 0.001), 37 mL at 12-24 months (n= 25, range 0-265, P < 0.001), 18 mL at 24-36 months (n= 17, range 0-205, P < 0.001) and 41 mL at 36-48 months (n= 6, range 0-66, P < 0.05). The median reduction in uterine volume was 40% (n= 46, 95% CI 33.0-49.7, P < 0.001). CONCLUSIONS: UAE causes a statistically significant reduction in objectively measured MBL. UAE is also associated with a statistically significant reduction in uterine volume at six months. There was no relationship between the changes in uterine volume and MBL.

Adult↗

Randomized clinical trial comparing self-expanding metallic stents with plastic endoprostheses in the palliation of oesophageal cancer.

BACKGROUND: There is little evidence of the clinical and cost effectiveness of self-expanding metallic stents in the palliation of oesophageal cancer. The aims of this randomized trial were to evaluate the immediate and medium-term clinical outcomes following palliative intubation, examine patient quality of life, and evaluate costs and benefits from the perspective of the health service. METHODS: Fifty patients with inoperable oesophageal cancer were randomly allocated a metallic stent (n = 25) or plastic endoprosthesis (n = 25). Patients were followed up monthly until death. RESULTS: There was no significant difference in procedure-related complications or mortality rate between the two groups. There was a trend towards significance in favour of metallic stents with respect to quality of life and survival (median survival 62 versus 107 days for plastic prosthesis and metallic stent respectively). The cost of the initial placement of metallic stents was significantly higher than that of plastic endoprostheses ( pound 983 versus pound 296). After 4 weeks, cost differences were no longer significant. CONCLUSION: Metallic stents may contribute to improved survival and quality of life in patients with oesophageal cancer. Although initially more expensive, this cost difference does not last beyond 4 weeks. A larger trial involving approximately 300 patients would be required to detect a quality of life benefit of the magnitude observed in this trial.

Adult↗

Common iliac artery access during endovascular thoracic aortic repair facilitated by a transabdominal wall tunnel.

PURPOSE: To describe a technique for common iliac artery (CIA) access during endovascular aortic aneurysm repair when unfavorable angulation between the CIA and the delivery sheath precludes direct arterial access. TECHNIQUE: After retroperitoneal exposure of the CIA, a puncture site is chosen inferolateral to the surgical incision, and an 18-G trocar/cannula is advanced in alignment with the CIA through the anterior abdominal wall or skin of the upper thigh into the retroperitoneal space. Serial dilatation is performed over a guidewire placed through the cannula to create the subcutaneous tract. The trocar/cannula is replaced over the wire, and the CIA is punctured under direct vision. The guidewire is then advanced into the proximal aorta. A CIA arteriotomy is performed and the delivery system introduced over the guidewire through the tunnel into the iliac artery. CONCLUSIONS: Retroperitoneal exposure of the CIA with tunneled transabdominal wall delivery of the stent-graft avoids both external iliac artery injury and creation of a temporary access conduit in patients with iliac tortuosity and/or occlusive disease.

Abdominal Muscles↗

Comparison of technical success and outcome of tunneled catheters inserted via the jugular and subclavian approaches.

PURPOSE: To compare the technical success and immediate and long-term outcomes of tunneled central venous catheters placed in comparative cohorts via the subclavian vein (SCV) and the internal jugular vein (IJV) routes. MATERIALS AND METHODS: This was a prospective observational single-center study of consecutive procedures. Between November 1993 and June 1995, 99 catheters were placed via the SCV and between December 1997 and July 1998, 109 catheters were placed via the IJV. Procedural data were recorded in both cohorts by completion of a proforma by the primary operator. RESULTS: Follow-up data were available in 96% of the SCV and 87% of the IJV cohorts. The average procedure time was significantly shorter in the IJV group and technical success was 100% versus 97% in the SCV group, but this did not reach statistical significance. The procedure-related pneumothorax rate and the rate of symptomatic venous thrombosis were significantly lower in the IJV cohort (P = .023, P = .015). Fewer catheters were removed prematurely due to sepsis in the IJV group (P = .043). CONCLUSIONS: The IJV route is associated with comparable technical success, and lower major procedural complication and venous thrombosis rates, with fewer catheters removed prematurely. The right IJV approach with ultrasound guidance is recommended as the route of choice for the placement of tunneled central venous catheters.

Catheterization, Central Venous↗

Percutaneous fibrin sleeve stripping of failing haemodialysis catheters.

BACKGROUND: One of the most frequent reasons for failure of haemodialysis lines is catheter blockage caused by fibrin sheath formation. We report our experience of percutaneous fibrin sheath stripping in treating this problem. METHODS: A consecutive series of failing haemodialysis catheters underwent percutaneous fibrin sheath stripping in an attempt to retrieve and prolong the life of the catheter. Immediate technical success, clinical success, and primary and secondary patency were measured based on clinical follow-up. RESULTS: Sixteen non-functional permanent haemodialysis lines in 15 patients underwent percutaneous fibrin sheath stripping on 21 occasions. Technical success rate was 100%. Catheter flow rates sufficient for initial dialysis were achieved in 12 (75%) lines. Successful percutaneous fibrin sheath stripping produced a mean catheter patency of 126 days (range 6-299 days). CONCLUSIONS: Percutaneous fibrin sheath stripping is a simple, repeatable procedure that can usefully extend the life of a failing dialysis line. However, a randomized trial will be needed to evaluate its role compared with catheter replacement.

Catheterization↗

Salvage of the solitary kidney by insertion of a renal artery stent.

OBJECTIVE: The purpose of the study was to evaluate the use of renal artery stents in the solitary functioning kidney of patients who have impaired renal function as a result of atherosclerotic renovascular disease by assessing primary patency, renal function outcome, and complication rates during a mean follow-up period of 15 months. MATERIALS AND METHODS: The Palmaz stent was placed in the arteries of 21 patients with solitary functioning kidneys. All patients had impaired renal function (creatinine level >150 micromol/l), and four patients were undergoing renal dialysis. Indications for stenting were recoil after percutaneous transluminal angioplasty (n = 12), arterial dissection after angioplasty (n = 2), restenosis after angioplasty (n = 1), and as the primary intervention (n = 6). Follow-up angiography was performed in 16 patients (76%). RESULTS: Initial technical success was achieved in all patients (residual stenosis, <5%). At follow-up (range, 6-25 months), renal function had returned to normal in five patients (24%), improved in four patients (19%), stabilized in six patients (29%), and deteriorated in six patients (29%). Dialysis has been discontinued in all four dialysis patients. Major complications occurred in four patients (19%), including one death within 30 days of stenting. No significant restenoses were seen on follow-up angiography. CONCLUSION: Placement of renal artery stents in the solitary kidney led to benefits in 70% of patients treated, including improved renal function in nine patients (43%) and stabilization in six patients (29%). In this high-risk group of patients, we advocate renal artery stenting as a relatively safe procedure to salvage the solitary kidney.

Arteriosclerosis↗

Effect of renal-artery stenting on progression of renovascular renal failure.

BACKGROUND: Placement of renal-artery stents has a high technical success rate in atherosclerotic renovascular disease, but little is known about the clinical benefits of the procedure. We monitored renal function serially before and after stent insertion in patients with renovascular renal failure. METHODS: Renal function was assessed before and after stent placement by means of serial serum creatinine values in 32 patients with atherosclerotic renal-artery stenosis. The effect on the progression of renal failure was analysed in 23 patients by comparison of the reciprocal slopes of serum creatinine versus time plots before and after stent placement. FINDINGS: 33 transluminal stents were placed in 32 patients with atherosclerotic renovascular disease. Immediate patency was achieved in all cases: the angiographic restenosis rate at 6 months was 12% (n = 24). One patient died after a procedure-related haemorrhage. Median diastolic blood pressure was significantly lower after stenting than before (95 [IQR 86-103] vs 87 [81-90] mm Hg; p > 0.01) but the requirement for antihypertensive drugs was unchanged. Renal function improved or stabilised in 22 (69%) of the 32 patients. Progression of renal failure was significantly slowed after the procedure; the mean (SE) of the slopes of reciprocal serum creatinine values was -4.34 (0.85) L mumol-1 day-1 before stent placement, and -0.55 (1.0) L mumol-1 day-1 after stent placement (p < 0.01, two-sample t test). INTERPRETATION: Renal-stent placement in selected patients slows the progression of renovascular renal failure and may delay the need for renal replacement therapy.

Aged↗

Renal artery stent placement in renal artery stenosis: technical and early clinical results.

We report the technical and early clinical results of renal artery stent placement in 29 consecutive patients treated at a single centre over a 30-month period, employing the Palmaz balloon-expandable stent. Of 32 arteries treated, 23 (72%) were atheromatous, ostial stenoses. Immediate technical success was achieved in all 29 patients. Follow-up angiography was performed on 25 patients at 6.7 months (mean) and demonstrated a patient restenosis rate of 16%. All surviving patients were followed up for a minimum of 6 months. Blood pressure control was improved in eight (50%) of hypertensive patients, and renal function improved in seven (33%) and stabilized in six (29%) patients with chronic renal impairment (serum creatinine > 150 mumols/l). Complications occurred in seven (24%) of patients, including one procedure-related death. Our experience indicates that stent placement has an initial high technical success rate in renal artery stenosis and that this patency is maintained at repeat angiography with a low restenosis rate. Renal artery stenting is likely to extend the role of percutaneous renal revascularization especially in atheromatous ostial lesions. A randomized trial will be required to evaluate its role compared with balloon angioplasty.

Adult↗

Colour Doppler ultrasound in renal artery stenosis: intrarenal waveform analysis.

Renal artery stenosis (RAS) is the commonest secondary cause of hypertension and may result in renal ischaemia with resultant renal failure. Recent studies hve suggested that colour Doppler ultrasound, with spectral analysis of the intrarenal waveforms, can identify those patients with a significant RAS. A prospective study was performed in which colour Doppler ultrasound was compared with angiography in 73 patients (143 kidneys) presenting for renal angiography. Colour Doppler ultrasound was unsuccessful in 16% of kidneys due to a combination of technical failures and small kidney size. Accessory renal vessels were present in 14% of kidneys on angiography but none was detected by ultrasound. Of the 120 kidneys that had both examinations, no significant difference in intrarenal pulsatility or resistive index was noted between the angiographically stenosed and normal arteries. There were significant differences for intrarenal peak and end diastolic velocities, and acceleration time and index. Of these measurements, acceleration time was the best indicator of RAS. The probability of detecting a high grade RAS in an individual patient did not reach 90% until the acceleration time was prolonged to more than 0.12 s. Intrarenal colour Doppler ultrasound is not a general screening test for RAS and it should be reserved for selected patient groups where the incidence of disease is high. Patients with prolonged acceleration times of more than 0.12 s have a high likelihood of at least 70% RAS and should proceed directly to angiography.

Adult↗

Colour Doppler ultrasound in renal transplant artery stenosis: which Doppler index?

A prospective study comparing colour Doppler ultrasound (US) with the 'gold standard' of intra-arterial digital subtraction angiography in the evaluation of renal transplant artery stenosis was performed. Both the intrarenal vessels and the transplant renal artery were examined by Doppler US. Diagnostic arteriography was performed only if, on Doppler, the peak systolic velocity in the transplant renal artery exceeded 1.5 ms-1. Of 109 patients, the transplant artery could not be visualized using colour Doppler US in three, and these were omitted from statistical analysis. Of the remaining 106 patients, 31 had a peak systolic velocity greater than 1.5 ms-1 in the transplant renal artery and were referred for DSA. Of the multiple renal Doppler indices recorded, the peak systolic velocity in the transplant artery was the best discriminating measurement for the detection of renal artery stenosis. A peak systolic velocity of > or = 2.5 ms-1 in the transplant renal artery had a sensitivity of 100% and a specificity of 95% for the detection of renal artery stenosis ( > 50% diameter reduction). Although a significant difference in Pulsatility Index, Resistive Index, Acceleration Index and Acceleration Time was recorded from the intrarenal vessels in the angiographically normal and stenosed groups with Doppler, these measurements were less useful as discriminating diagnostic tests. In conclusion, the peak systolic velocity in the transplant renal artery is the most sensitive Doppler criterion for renal artery stenosis and is sensitive and specific enough to be used as a screening test. The intrarenal acceleration time and index should not be used in isolation.

Angiography, Digital Subtraction↗

Vascular occlusion with a balloon-expandable stent occluder.

PURPOSE: To evaluate the effectiveness of a new vascular occlusion device. MATERIALS AND METHODS: The device was created by coating a balloon-expandable stent with a silicone sleeve that tapers to a blind-ended nozzle at its leading end. Once crimp-mounted on an angioplasty balloon catheter, the device is introduced over a guide wire through a small end hole in the nozzle. RESULTS: The device was tested for stability and occlusive ability. No migration was measured over a pulsatile pulse range of 50-300 mm Hg, and mean flow rate in the occluded vessel was reduced from 443 mL/min +/- 99 (standard deviation) to 1.9 mL/min +/- 2.7. Subsequently, 12 arteries were occluded in three dogs, and immediate vascular occlusion was achieved in all vessels. An arteriovenous fistula was created in another six dogs and was successfully occluded with the device. Follow-up arteriography at 3 months demonstrated persistent occlusion with no migration of the device. CONCLUSION: This new occlusive device offers immediate vascular occlusion with excellent stability.

Angioplasty, Balloon↗

Is radiology a 'nine to five' specialty?

The role of the radiologist in 'out of hours' radiology was prospectively studied in a single Scottish Health Board for a continuous 6 month period. Six hundred and sixty seven procedures were performed by radiologists. Computed tomography (CT) (274, 41%), ultrasound scans (190, 28.5%) and vascular/interventional procedures (60, 9%) were the most frequently performed procedures. Trauma accounted for 139 (24%) of all 'out of hours' work and overall 365 (54.7%) procedures yielded an abnormality. The workload varied widely between hospitals from two procedures per 100 beds to 137 procedures per 100 beds. Similarly the input from individual radiologists was very variable. A registrar was present for 227 (34%) procedures, a senior registrar for 360 (54%) and a consultant for 138 (20%) (there being two radiologists present for 8.7% of procedures). 'Consultant only' radiology departments offering a full radiological service may expect a substantial 'out of hours' commitment.

Medical Audit↗

Comparison of temperature profiles (DeVeTherm) and conventional venography in suspected lower limb thrombosis.

In 124 patients admitted with suspected acute deep venous thrombosis, the screening value of a new thermographic scanner, DeVeTherm, was evaluated using conventional venography as a reference. The sensitivity of the scanner was calculated at 92% and the specificity at 25%. The predictive value of positive temperature profiles was 0.48, and that of negative temperature profiles, 0.82. On the basis of these results neither the accuracy nor the potential savings justify using temperature profiles alone as a screening test for this condition.

Adult↗