PubMed Health⌕ Search

Biomedical subjects

J G Raya

Publications and source records attributed to J G Raya.

5 recordsLinked to original sources

Techniques for diffusion-weighted imaging of bone marrow.

Diffusion-weighted magnetic resonance imaging (DWI) is an imaging technique which is sensitive to random water movements in spatial scales far below those typically accessible by magnetic resonance imaging (MRI). This property makes DWI a powerful tool for diagnosis of diseases which involve alterations in water mobility, such as acute stroke. In bone marrow, DWI has been proven to be a highly useful method for the differential diagnosis of benign and malignant compression fractures. Unfortunately, the application of DWI sequences to the bone marrow frequently suffers from artifacts, which in some cases seriously restrict the diagnostic utility of the image. This requires the introduction of additional correction techniques, or even the development of new sequences. Thus, the selection of an adequate imaging technique for DWI of the bone marrow is a very important issue. In this article the most important sequences for DWI of the bone marrow are reviewed. Special attention is paid to the problems associated with these sequences, as well as their possible solutions.

Artifacts↗

Sustained firing of alpha and gamma hind limb motoneurons induced by stimulation of the pudendal nerve.

Axons from receptors in the cat vaginal wall run in the sensory pudendal nerve (SPN), and brief (<10 s) vaginal probing (VP) in the decerebrate cat produces a long-lasting (>1 min) contraction of the triceps surae (TS) muscles. The aim of the present project was to find out whether brief SPN stimulation also produces sustained TS response and, eventually, to study the mechanisms involved in it. Decerebrate female cats were used. In some cats, TS electromyography (EMG) and tension response were recorded; stimulation of left SPN with single or repetitive trains of shocks produced a bilateral TS response that outlasted the stimulus >1 min as VP did. In paralyzed cats (pancuronium; Panc), intracellular recordings were made from hind limb motoneurons (MNs). SPN stimulation produced a depolarization 1 min) electroneurographic (ENG) postdischarge in a small filament of the medial gastrocnemius (MG) nerve; the MG EMG postdischarge was also recorded. Large spikes (LS) and small spikes (SS) were distinguished in the ENG. During the postdischarge, LS frequency and the integrated EMG activity correlated well (r > 0.9); no correlation was found between SS and EMG. After Panc injection, LS postdischarge was absent but the SS postdischarge remained. LS followed by EMG potential were also evoked by brief TS stretch (reflex LS); single shocks to SPN only elicited SS that were not followed by EMG potential. It is concluded that alpha axons and gamma axons produced LS and SS, respectively, and that SPN activates gamma axons. It is proposed that, in the nonparalyzed cats, the stimulation of SPN with trains of shocks might cause an increase in the afferent inflow from muscle spindles to alpha MNs through the sustained firing of gamma MNs. The increased excitatory inflow would depolarize alpha MNs and allow bistable MN firing; Panc would decrease this inflow by blocking transmission to the spindle fibers.

Action Potentials↗

Methods to find aponeurosis and tendon stiffness and the onset of muscle contraction.

A method to measure small movements of living tissues either large or small is presented. The method is based on the detection of changes in reflected infrared light. An optocoupler (coupled photodiode and photodetector) and a small (< 1 cm2) mirror were used. The optocoupler (OC) has a low cost and it can be calibrated easily. It can be also used as the transducer of a strain-gage. Three different uses are shown: (a) as a strain-gage transducer; (b) detection of tendon and aponeurosis movements in large muscles (cat soleus); (c) detection of the onset of muscle contraction. Movements of less than 1 microm can be detected with the aid of automatic averaging of the signals. Concerning the second use (b), it permits the estimation of tendon stretch. Concerning the third use, the onset of muscle movement precedes by at least 2 ms that of the force recorded at the tendon.

Achilles Tendon↗

The cat pudendal nerve: afferent fibers responding to mechanical stimulation of the perineal skin, the vagina or the uterine cervix.

Some afferent fibers from the pudendal nerve of the female cat were stimulated by pressing on the perineal skin, the vagina or the uterine cervix. Three different types of skin mechanoreceptors were found: (1) with low threshold (< 20 mg) and slow-adapting discharges; (2) with high threshold (0.1-0.5 g) and slow-adapting discharges; and (3) with low threshold and fast-adapting discharges. Most of these receptors increased their firing frequency as the velocity of skin indentation was increased (velocity detectors). The average conduction velocity of the skin afferents was 29 +/- 9 m/s. The receptors located at the vagina showed a fast-adapting response to probing and were sensitive to the velocity of the probe movement. Most of these receptors, however, showed a slow adaptation when the vaginal wall was distended with a balloon. The conduction velocity in vaginal afferents was 37 +/- 16 m/s. Those receptors responding to pressure on the uterine cervix adapted slowly to constant pressure but were sensitive to the velocity of the pressure pulses. The conduction velocity in the afferents from the uterine cervix was 31 +/- 9 m/s.

Adaptation, Physiological↗

Sustained activation of the triceps surae muscles produced by mechanical stimulation of the genital tract of the female cat.

In decerebrate cats, controlled mechanical stimulation of the perivulvar skin, the vaginal wall or the cervix uteri induced visible hind limb extension. Pressing on the cervix uteri produced the greater response. To quantify these responses, the EMG activity and the tension developed by the normally inserted triceps surae muscles were recorded. The activity induced in these muscles by stimulation of the genital canal outlasted the stimulus by many seconds or a few minutes. These effects disappeared after spinalization at the T12 level. We propose that stimulation of the vaginal canal in the female cat may induce bistability of triceps surae motoneurones.

Animals↗