Work of breathing using high-flow nasal cannula in preterm infants.

OBJECTIVE: To compare the work of breathing (WOB) in premature neonates supported with high-flow nasal cannula (HFNC) and nasal continuous positive airway pressure (NCPAP). STUDY DESIGN: Eighteen preterm neonates <2.0 kg on HFNC or NCPAP support were studied in a random order. A ventilator was used to deliver 6 cm H2O of NCPAP with nasal prongs. High-flow nasal cannula delivered with Vapotherm (VAPO) at 3, 4 and 5 l/min was used. Tidal ventilation was obtained using respiratory inductance plethysmography calibrated with face-mask pneumotachography. An esophageal balloon estimated pleural pressure from which changes in end distending pressure were calculated. Inspiratory, elastic and resistive WOB and respiratory parameters were calculated. RESULTS: No differences were found in the WOB for all settings. Changes in end distending pressure did not vary significantly over all device settings except VAPO at 5 l/min. CONCLUSION: In these preterm infants with mild respiratory illness, HFNC provided support comparable to NCPAP.

Continuous Positive Airway Pressure↗

Fluconazole prophylaxis in extremely low birth weight infants: association with cholestasis.

BACKGROUND: Extremely low birth weight (ELBW) infants are at increased risk for invasive candidiasis and associated morbidity and mortality. The use of fluconazole prophylaxis in this population has raised a benefit versus risk concern among clinicians. OBJECTIVES: To evaluate the effectiveness and safety of fluconazole prophylaxis in ELBW infants. STUDY DESIGN: ELBW infants (BW<or=1,000 g) born during the pre-prophylaxis era (PPE, January 1998-February 2002) were compared with prophylaxis era (PE, March 2002-September 2005). Infants born during PE received fluconazole prophylaxis for 6 weeks, as long as they had intravenous access. Demographic and clinical data were collected. The two groups were compared for baseline demographics, risk factors for candidiasis, the incidence of invasive candidiasis, liver enzymes, alkaline phosphatase, and bilirubin (total and direct). RESULTS: Nine out of 137 infants (6.6%) developed invasive candidiasis during PPE compared to none of 140 (0%) during PE (P=0.006). During PE, 60/140 (42.9%) infants developed conjugated hyperbilirubinemia compared to 12/137 (8.8%) during PPE (P<0.001). CONCLUSION: Although a fluconazole prophylaxis regimen for ELBW infants was effective in preventing invasive candidiasis, an increase in the incidence of conjugated hyperbilirubinemia was observed. Further studies are needed to evaluate the safety of fluconazole prophylaxis in this population.

Alkaline Phosphatase↗

Lung recruitment and breathing pattern during variable versus continuous flow nasal continuous positive airway pressure in premature infants: an evaluation of three devices.

OBJECTIVE: To determine whether lung volume changes and breathing pattern parameters differ among 3 devices for delivery of nasal continuous positive airway pressure (CPAP) in premature infants. METHODS: Thirty-two premature infants receiving nasal CPAP for apnea or mild respiratory distress were enrolled. Birth weight was (mean +/- standard deviation) 1081 +/- 316 g, gestational age 29 +/- 2 weeks, age at study 13 +/- 12 days, and fraction of inspired oxygen (FIO(2)) at study.29 +/-.1. Three devices, applied in random order, were studied in each infant: continuous flow nasal CPAP via CPAP prongs, continuous flow nasal CPAP via modified nasal cannula, and variable flow nasal CPAP. After lung recruitment to standardize volume history, changes in lung volume (DeltaV(L)) were assessed at nasal CPAP of 8, 6, 4, and 0 cm H(2)O using calibrated direct current-coupled respiratory inductance plethysmography. RESULTS: DeltaV(L) was significantly greater overall with the variable flow device compared with both the nasal cannula and CPAP prongs. However, DeltaV(L) was not different between the cannula and the prongs. Respiratory rate, tidal volume, thoraco-abdominal asynchrony, and FIO(2) were greater with the modified cannula than for either of the other 2 devices. CONCLUSION: Compared with 2 continuous flow devices, the variable flow nasal CPAP device leads to greater lung recruitment. Although a nasal cannula is able to recruit lung volume, it does so at the cost of increased respiratory effort and FIO(2).

Apnea↗

Work of breathing during constant- and variable-flow nasal continuous positive airway pressure in preterm neonates.

BACKGROUND: Constant-flow nasal continuous positive airway pressure (NCPAP) often is used in preterm neonates to recruit and maintain lung volume. Physical model studies indicate that a variable-flow NCPAP device provides more stable volume recruitment with less imposed work of breathing (WOB). Although superior lung recruitment with variable-flow NCPAP has been demonstrated in preterm neonates, corroborating WOB data are lacking. OBJECTIVE: To measure and compare WOB associated with the use of variable-flow versus constant-flow NCPAP in preterm neonates. METHODS: Twenty-four preterm infants who were receiving constant-flow NCPAP (means, SD) and had birth weight of 1024 +/- 253 g, gestational age of 28 +/- 1.7 weeks, age of 14 +/- 13 days, and FIO(2) of 0.3 +/- 0.1 were studied. Variable-flow and constant-flow NCPAP were applied in random order. We measured changes in lung volume and tidal ventilation (V(T)) by DC-coupled/calibrated respiratory inductance plethysmography as well as esophageal pressures at NCPAP of 8, 6, 4, and 0 cm H(2)O. Inspiratory WOB (WOB(I)) and lung compliance were calculated from the esophageal pressure and V(T) data using standard methods. WOB was divided by V(T) to standardize the results. RESULTS: WOB(I) decreased at all CPAP levels with variable-flow NCPAP, with a maximal decrease at 4 cm H(2)O. WOB(I) increased at all CPAP levels with constant-flow CPAP. Lung compliance increased at all NCPAP levels with variable-flow, with a relative decrease at 8 cm H(2)O, whereas it increased only at 8 cm H(2)O with constant-flow NCPAP. Compared with constant-flow NCPAP, WOB(I) was 13% to 29% lower with variable-flow NCPAP. CONCLUSION: WOB(I) is decreased with variable-flow NCPAP compared with constant-flow NCPAP. The increase in WOB(I) with constant-flow NCPAP indicates the presence of appreciable imposed WOB with this device. Our study, performed in neonates with little lung disease, indicates the possibility of lung overdistention at CPAP of 6 to 8 cm H(2)O with the variable-flow device. Further study is necessary to determine the efficacy of variable-flow NCPAP in neonates with significant lung disease and its use over extended periods of time.continuous-flow and variable-flow NCPAP, work of breathing, premature neonates, lung compliance.

Equipment Design↗

Thyroid screening for early discharged infants.

OBJECTIVE: As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. METHODS: During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. RESULTS: Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 microIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. CONCLUSIONS: Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.

Congenital Hypothyroidism↗

Effect of dose formulation on isoniazid absorption in two young children.

In an 8-month-old infant with tuberculous meningitis treatment with isoniazid was unsuccessful and was associated with lower than expected plasma concentrations of isoniazid (measured concentration 0.1 microgram/mL). The infant had received isoniazid as a crushed tablet admixed with apple sauce. Oral administration of the parenteral solution of isoniazid (Nydrazid, Squibb) mixed in apple juice produced a higher isoniazid concentration (2.9 micrograms/mL) and the child improved clinically. Pharmacokinetic studies in two subjects were performed following intramuscular injection of isoniazid and oral administration of (1) an isoniazid tablet crushed and mixed with apple sauce, (2) parenteral isoniazid solution mixed with apple juice, and (3) a commercially available syrup containing isoniazid and pyridoxine (P-I-N Forte, Lannett). Of the three oral preparations, the syrup produced the highest peak concentrations (8.3 and 6.9 micrograms/mL). The crushed tablets in apple sauce produced the lowest peak concentrations (1.4 and 2.4 micrograms/mL). Administration of crushed isoniazid tablets with food may be associated with impaired gastrointestinal absorption, lower than expected isoniazid concentrations, and treatment failure.

Administration, Oral↗