PubMed Health⌕ Search

Biomedical subjects

J G Sled

Publications and source records attributed to J G Sled.

9 recordsLinked to original sources

Comparing microsphere deposition and flow modeling in 3D vascular trees.

Blood perfusion in organs has been shown to be heterogeneous in a number of cases. At the same time, a number of models of vascular structure and flow have been proposed that also generate heterogeneous perfusion. Although a relationship between local perfusion and vascular structure has to exist, no model has yet been validated as an accurate description of this relationship. A study of perfusion and three-dimensional (3D) arterial structure in individual rat kidneys is presented, which allows comparison between local measurements of perfusion and model-based predictions. High-resolution computed tomography is used to obtain images of both deposited microspheres and of an arterial cast in the same organ. Microsphere deposition is used as an estimate of local perfusion. A 3D cylindrical pipe model of the arterial tree is generated based on an image of the arterial cast. Results of a flow model are compared with local microsphere deposition. High correlation (r(2) > 0.94) was observed between measured and modeled flows through the vascular tree segments. However, the relative dispersion of the microsphere perfusion measurement was two- to threefold higher than perfusion heterogeneity calculated in the flow model. Also, there was no correlation in the residual deviations between the methods. This study illustrates the importance of comparing models of local perfusion with in vivo measurements of perfusion in the same biologically realistic vascular tree.

Animals↗

Regional variations in normal brain shown by quantitative magnetization transfer imaging.

A quantitative magnetization transfer imaging (qMTI) study, based on a two-pool model of magnetization transfer, was performed on seven normal subjects to determine, on a regional basis, normal values for the pool sizes, exchange, and relaxation parameters that characterize the MT phenomenon. Regions were identified on high-resolution anatomical scans using a combination of manual and automatic methods. Only voxels identified as pure tissue at the resolution of the quantitative scans were considered for analysis. While no left/right differences were observed, significant differences were found among white-matter regions and gray-matter regions. These regional differences were compared with existing cytoarchitectural data. In addition, the pattern and magnitude of the regional differences observed in white matter was found to be different from that reported previously for an alternative putative MRI measure of myelination, the 10-50-ms T2 component described as myelin water.

Adult↗

Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI.

We describe a novel imaging technique that yields all of the observable properties of the binary spin-bath model for magnetization transfer (MT) and demonstrate this method for in vivo studies of the human head. Based on a new model of the steady-state behavior of the magnetization during a pulsed MT-weighted imaging sequence, this approach yields parametric images of the fractional size of the restricted pool, the magnetization exchange rate, the T(2) of the restricted pool, as well as the relaxation times in the free pool. Validated experimentally on agar gels and samples of uncooked beef, we demonstrate the method's application on two normal subjects and a patient with multiple sclerosis.

Animals↗

Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects.

The desire to correct intensity nonuniformity in magnetic resonance images has led to the proliferation of nonuniformity-correction (NUC) algorithms with different theoretical underpinnings. In order to provide end users with a rational basis for selecting a given algorithm for a specific neuroscientific application, we evaluated the performance of six NUC algorithms. We used simulated and real MRI data volumes, including six repeat scans of the same subject, in order to rank the accuracy, precision, and stability of the nonuniformity corrections. We also compared algorithms using data volumes from different subjects and different (1.5T and 3.0T) MRI scanners in order to relate differences in algorithmic performance to intersubject variability and/or differences in scanner performance. In phantom studies, the correlation of the extracted with the applied nonuniformity was highest in the transaxial (left-to-right) direction and lowest in the axial (top-to-bottom) direction. Two of the six algorithms demonstrated a high degree of stability, as measured by the iterative application of the algorithm to its corrected output. While none of the algorithms performed ideally under all circumstances, locally adaptive methods generally outperformed nonadaptive methods.

Algorithms↗

Correction for B(1) and B(0) variations in quantitative T(2) measurements using MRI.

A new method is described for compensating for the bias introduced by variations in radiofrequency (RF) field strength and main magnetic field strength when making quantitative T(2) measurements using MRI. Field measurements made during the MRI study are used in combination with a signal model for off-resonance and imperfect RF pulses to correct the estimated T(2) value at every voxel. Applicable to both multicomponent and conventional single-component T(2) studies, the method has been validated experimentally using paramagnetic salt solutions in a multicompartment phantom. Studies of the human head are used to demonstrate the method in practice.

Artifacts↗

Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences.

A method for analyzing general pulsed magnetization transfer (MT) experiments in which off-resonance saturation pulses are interleaved with on-resonance excitation pulses is presented. We apply this method to develop a steady-state signal equation for MT-weighted spoiled gradient echo sequences and consider approximations that facilitate its rapid computation. Using this equation, we assess various experimental designs for quantitatively imaging the fractional size of the restricted pool, cross-relaxation rate, and T(1) and T(2) relaxation times of the two pools in a binary spin bath system. From experiments on agar gel, this method is shown to reliably and accurately estimate the exchange and relaxation properties of a material in an imaging context, suggesting the feasibility of using this technique in vivo.

Image Interpretation, Computer-Assisted↗

A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

A novel approach to correcting for intensity nonuniformity in magnetic resonance (MR) data is described that achieves high performance without requiring a model of the tissue classes present. The method has the advantage that it can be applied at an early stage in an automated data analysis, before a tissue model is available. Described as nonparametric nonuniform intensity normalization (N3), the method is independent of pulse sequence and insensitive to pathological data that might otherwise violate model assumptions. To eliminate the dependence of the field estimate on anatomy, an iterative approach is employed to estimate both the multiplicative bias field and the distribution of the true tissue intensities. The performance of this method is evaluated using both real and simulated MR data.

Brain↗

Design and construction of a realistic digital brain phantom.

After conception and implementation of any new medical image processing algorithm, validation is an important step to ensure that the procedure fulfills all requirements set forth at the initial design stage. Although the algorithm must be evaluated on real data, a comprehensive validation requires the additional use of simulated data since it is impossible to establish ground truth with in vivo data. Experiments with simulated data permit controlled evaluation over a wide range of conditions (e.g., different levels of noise, contrast, intensity artefacts, or geometric distortion). Such considerations have become increasingly important with the rapid growth of neuroimaging, i.e., computational analysis of brain structure and function using brain scanning methods such as positron emission tomography and magnetic resonance imaging. Since simple objects such as ellipsoids or parallelepipedes do not reflect the complexity of natural brain anatomy, we present the design and creation of a realistic, high-resolution, digital, volumetric phantom of the human brain. This three-dimensional digital brain phantom is made up of ten volumetric data sets that define the spatial distribution for different tissues (e.g., grey matter, white matter, muscle, skin, etc.), where voxel intensity is proportional to the fraction of tissue within the voxel. The digital brain phantom can be used to simulate tomographic images of the head. Since the contribution of each tissue type to each voxel in the brain phantom is known, it can be used as the gold standard to test analysis algorithms such as classification procedures which seek to identify the tissue "type" of each image voxel. Furthermore, since the same anatomical phantom may be used to drive simulators for different modalities, it is the ideal tool to test intermodality registration algorithms. The brain phantom and simulated MR images have been made publicly available on the Internet (http://www.bic.mni.mcgill.ca/brainweb).

Brain↗

Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI.

Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging an elliptically shaped object using 1.5-T magnets and circularly polarized RF coils. This first principle analysis clarifies, for the general case of conducting objects, the relationship between the excitation field and the reception sensitivity of circularly and linearly polarized coils. The results, validated experimentally using a standard spin-echo imaging sequence and an in vivo B1 field mapping technique, are shown to be accurate to within 1%-2% root mean square, suggesting that these electromagnetic interactions with the object account for most of the intensity nonuniformity observed.

Artifacts↗